Preferred Language
Articles
/
7xb8YYcBVTCNdQwCO0jQ
Bioactivity of Gutta flow II versus Modified Gutta Percha based Silicon Endodontic Sealers by Nanobioactive Fillers
...Show More Authors

The success of endodontic therapy is relied on radicular system cleaning, shaping, elimination of micro-organisms, and three dimensional filling of the radicular complex.This study was conducted to develop and assess new root canal sealer incorporating nano-sized bioactive glass into Gutta Flow II. The following concentration was used depend on a pilot study included adding (3%) of 45S5 bioactive glass into the Gutta Flow II. These materials were tested through assessment bioactivity. bioactivity test was undertaken after immersion of the tested samples into PBS for three days, seven days, fourteen days, and twenty eight days using FTIR too. study was found that it’s peaks was appear at level 800-1000 cm-1. The results showed that GFII group revealed no peak at the 910 cm-1, while, while BG3% revealed 179.85 pixel height, in conclusion the newly developed sealers exhibited apparent apatite and apatite precursor forming ability significantly with BG 3% while GuttaFlow II sealer showed no apatite layer forming ability.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Temperature effect on optical properties of nickel (ii) phthalocyanine tetrasulfonic acid tetrasodium salt (NiPcTs) organic thin films
...Show More Authors

This study describe the effect of temperature on the optical
properties of nickel(ii) phthalocyanine tetrasulfonic acid tetrasodium
salt (NiPcTs) organic thin films which are prepared by spin coating
on indium tin oxide (ITO-glass). The optical absorption spectra of
these thin films are measured. Present studies reveal that the optical
band gap energies of NiPcTs thin films are dependent on the
annealing temperatures. The optical band gap decreases with increase
in annealing temperature, then increased when the temperature rising
to 473K. To enhance the results of Uv-Vis measurements and get
more accurate values of optical energy gaps; the Photoluminescence
spectra of as-deposited and annealed NiPcTs thin fi

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Copper(II) using 2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole](MBBAI)
...Show More Authors

            Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Apr 08 2020
Journal Name
Biochemical & Cellular Archives .
PURIFICATION OF RHODANESE (RHD) AND ITS ASSOCIATION WITH MDA AND PEROXYNITRITE IN PATIENTS WITH TYPE II DIABETES.
...Show More Authors

Publication Date
Wed Nov 02 2016
Journal Name
Ibn Al-haitham Jour. For Pure & Appl. Sci.
Synthesis, Spectroscopic and Adsorption Studies of Cobalt (II) Complex for a ligand β-enaminone Derived from Sulfamethoxazole
...Show More Authors

This paper concerns is the preparation and characterization of a bidentate ligand [4-(5,5- dimethyl-3-oxocyclohex-1-enylamino)-N-(5-methylisoxazol-3-yl) benzene sulfonamide]. The ligand was prepared from fusing of sulfamethoxazole and dimedone at (140) ºC for half hour. The complex was prepared by refluxing the ligand with a bivalent cobalt ion using ethanol as a solvent. The prepared ligand and complex were identified using Spectroscopic methods. The proposed tetrahedral geometry around the metal ions studied were concluded from these measurements. Both molar ratio and continuous variation method were studied to determine metal to ligand ratio (M:L). The M to L ratio was found to be (1:1). The adsorption of cobalt complex was carried out

... Show More
Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Trypan Blue Exclusion Assay Verifies in Vitro Cytotoxicity of New Cis-Platinum (II) Complex in Human Cells
...Show More Authors

          Various assays are used to determine the toxic effects of drugs at cellular levels in vitro.  One of these methods is the dye exclusion assay, which measures membrane integrity in the presence of Trypan blue. Trypan blue the dye which was used in this study to investigate cytotoxic effect of a new Cis –dichloroplatinum (II) complex [(Qu)2PtCl2] on the viability of polymorphonuclear cells (PMNs). Three concentrations of platinum complex were prepared (70, 35and 17.5 µg/ ml) and the results revealed that the percentage of cell viability decreased as the platinum complex concentration increased in comparison with control.

... Show More
View Publication Preview PDF
Scopus (12)
Crossref (9)
Scopus Clarivate Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Study affects Pulse Parameters versus cavity length for both Dispersion Regimes in FM mode locked.: Bushra.R.Mhdi|Gaillan H.Abdullah|Mohand M.Azzawi|Nahla.A.Hessin|Basher.R.Mhdi
...Show More Authors

To demonstrate the effect of changing cavity length for FM mode locked on pulse parameters and make comparison for both dispersion regime , a plot for each pulse parameter as Lr function are presented for normal and anomalous dispersion regimes . The analysis is based on the theoretical study and the results of numerical simulation using MATLAB. The effect of both normal and anomalous dispersion regimes on output pulses is investigate Fiber length effects on pulse parameters are investigated by driving the modulator into different values. A numerical solution for model equations using fourth-fifth order, Runge-Kutta method is performed through MATLAB 7.0 program. Fiber length effect on pulse parameters is investigated by driving th

... Show More
View Publication
Crossref
Publication Date
Mon Sep 23 2024
Journal Name
European Journal Of Orthodontics
Poly-Ether-Ether-Ketone versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 2: periodontal health and microbial biofilm assessment
...Show More Authors
Abstract<sec> <title>Background

Retainers have the potential to detrimentally impact periodontal health and contribute to tooth decay.

Objectives

To investigate periodontal health and bacterial biofilm related to Poly-Ether-Ether-Ketone (PEEK) fixed retainers as compared to Dead-soft coaxial fixed retainer (DSC).

Trial design

A two-arm parallel groups single-centre randomized c

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Apr 01 2025
Journal Name
Journal Of Integrative Nursing
ShotBlocker versus vibration device: Which technique reduces pain and increases satisfaction in insulin injection among type 2 diabetes: A randomized controlled trial
...Show More Authors
Objective:

To evaluate the effects of the ShotBlocker and vibration device on pain intensity and patient satisfaction during subcutaneous (SC) insulin injections in hospitalized adults with type 2 diabetes mellitus.

Materials and Methods:

In this randomized controlled trial, 102 patients with type II diabetes mellitus were randomly assigned into 3 groups: 35 patients in the ShotBlocker group, 36 patients in the vibration group, and 31 patients in the control group. ShotBlocker was applied immediately before and during the injection, while the vibration was applied fo

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Tue Mar 27 2018
Journal Name
Mustansiria Dental Journal
The Effect of Modified Carisolv Gel on Surface Roughness of two Different Types of Ceramic Materials Using Light Polarizing Microscope
...Show More Authors

This in vitro study evaluated the influence of chemomechanical caries removal solution on the surface topography of metal-ceramic feldspar porcelain (MAJOR ceramic) and All-ceramic feldspar porcelain (Vita Alpha) using light polarizing microscope. Forty specimens of MAJOR ceramic and forty specimens of Vita Alpha ceramic of (12mm diameter & 3mm height) were prepared .All specimens were polished with silicon polishing burs, cleaned, autoglazed and stored in 37°C before exposure to Carisolv. Thirty specimens of each material randomly exposed to Carisolv gel for 5, 10 and 20 minutes respectively, other ten specimens were not, to act as control group. All specimens were subjected to surface roughness test by profilometer and evalua

... Show More
View Publication
Crossref
Publication Date
Thu Jun 11 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of adding of modified ZrO2-TiO2 nanoparticles on certain physical and mechanical properties of heat polymerized acrylic resin
...Show More Authors

Background: The mechanical and physical properties of Polymethyl methacrylate (PMMA) don’tfulfill the entire ideal requirements of denture base materials. The purpose of this study was to produce new modified polymer nanocomposite (PMMA /ZrO2-TiO2) andassess itsimpact strength, transverse strength and thermal conductivity in comparison to the conventionalheat polymerized acrylic resin. Materials and Methods: Both ZrO2 and TiO2nano fillers were silanized with TMSPM (trimethoxysilyl propyl methacrylate) silane coupling agent before beingdispersed by ultrasonication with the methylmethacrylate (monomer) and mixed with the polymer by means of 2% by weight in (1:1) ratio, 60 specimens were constructed by conventional water bath processing

... Show More
View Publication Preview PDF