Preferred Language
Articles
/
7oZXT4YBIXToZYALWIFO
stress and strain analysis for the prosthetic hand design actuated by links
...Show More Authors

Prosthetic hands are compensatory devices for the hand amputees as a result of injury, various accidents or birth deformities, types of prosthetic hand vary depending on the mechanism they operate and how they perform. There are common types in use that are characterized by their complex mechanisms, which are difficult for the amputee to use or exclude use because of their high cost, therefore the aim of this research is to design an artificial hand that is suitable in terms of simplicity of use and low cost and similar to a natural hand with regard to dimensions and shape that operated in the mechanism of links. This research involves Stress and strain analysis of the prosthetic hand and its fingers that modelled from (Petg CR) material. All design and analysis are done in the program Solidwork 2018 to find the effect of different load conditions on the designed hand by adding (normal load, ball grasping, cylinder rising). The von- Mises stresses deducted for a fingertip and assembled finger as well as the assembled hand to identify the maximum stress accrues before failure in daily life functions.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
European Journal Of General Medicine
The Value of Longitudinal Strain versus Coronary Angiography in Detection of Coronary Artery Disease
...Show More Authors

Aims: The aim of this study was to evaluate the value and accuracy of longitudinal strain in detection of coronary artery disease compared to coronary angiography. Results: The left ventricular longitudinal strain-speckle tracking showed evidence of stenosis of left anterior descending artery, circumflex artery and right coronary artery in (86.1%), (76.4%), and (84.7%) respectively. For the stenosis in left anterior descending artery, the current study showed that the longitudinal strain was a good predictor for presence of significant stenosis with a sensitivity of (93.8%), specificity (75%) and accuracy (91.7%) compared with coronary angiography. For the stenosis in right coronary artery, the left ventricular longitudinal strain had

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Mon Dec 01 2025
Journal Name
International Communications In Heat And Mass Transfer
Design optimization and performance analysis of a PCM-to-air heat exchanger with optimized fin configuration for building heating applications
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Complementary Therapies In Medicine
Effects of almond intake on oxidative stress parameters: A systematic review and meta-analysis of clinical trials
...Show More Authors

View Publication
Scopus (10)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
On The Nearby-Tip Strain Investigation and Failure-Propability Evaluation for Impacted Thin Plates Using the 2-Random-Variables Multi-Canonical-Based Joint Propability Distributions
...Show More Authors

The study of the validity and probability of failure in solids and structures is highly considered as one of the most incredibly-highlighted study fields in many science and engineering applications, the design analysts must therefore seek to investigate the points where the failing strains may be occurred, the probabilities of which these strains can cause the existing cracks to propagate through the fractured medium considered, and thereafter the solutions by which the analysts can adopt the approachable techniques to reduce/arrest these propagating cracks.In the present study a theoretical investigation upon simply-supported thin plates having surface cracks within their structure is to be accomplished, and the applied impact load to the

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue May 19 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The influence of shifting the class I cavity position prepared in posterior teeth buccally and lingualy on stress distribution (Finite element analysis study)
...Show More Authors

Background: Rehabilitation of the carious tooth to establish tooth structure integrity required cavity design that show a benign stress distribution. The aim of this study was to investigate the influence of the cavity position on the stress values in the reamining tooth structure restored with amalgam or resin composite. Materials and methods: Seven 2-D models of maxillary first premolar include class I cavity design was prepared, one sound tooth (A) 3 composite (B1, B2, and B3) and 3 amalgam (C1, C2, and C3). In design (BI and C1) the cavity position is in the mid distance between bacc-lingual cusp tip, design (B2 and C2) and (B3 and C3) shifted toward the buccal cusp and the lingual cusp for 0.5 mm respectively. One hundred N vertical

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 18 2023
Journal Name
Electronics
A Systematic Approach to Stable Grasping of a Two-Finger Robotic Hand Activated by Jamming of Granular Media
...Show More Authors

A systematic approach is presented to achieve the stable grasping of objects through a two-finger robotic hand, in which each finger cavity was filled with granular media. The compaction of the latter, controlled by vacuum pressure, was used to adjust the structural and contact stiffness of the finger. The grasping stability was studied under the concurrent effect of an external torque and applied vacuum pressure. Stable grasping was defined as the no slippage condition between the grasped object and the two fingers. Three control schemes were adopted and applied experimentally to ensure the effectiveness of the grasping process. The results showed that stable and unstable grasping regions exist for each combination of applied torqu

... Show More
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
2nd International Conference On Materials Engineering & Science (iconmeas 2019)
FEM analysis and design of permanent magnet disk type magneto-rheological (MR) valve
...Show More Authors

View Publication
Scopus (3)
Scopus Crossref
Publication Date
Tue Feb 01 2022
Journal Name
Journal Of Engineering
Design And Analysis Performance of Liquid Petroleum Gases System in Residential Building; Review
...Show More Authors

Liquefied petroleum gases (LPG) consist of hydrocarbons obtained by refining crude oil, either from propane or butane or a mixture of the two. There are often other components such as propylene, butylene or other hydrocarbons, but they are not the main component. The study aims to review previous studies dealing with designing an LPG system to deliver gas to residential campuses and buildings. LPG is extracted from natural gas NG by several processes, passing through fractionation towers and then pressuring into CNG storage tanks. Gas contains several problems, including gas leakage through the pipes and leads to fires or explosions in LPG storage and distribution tanks, so safety conditions were taken in the design and implementation. T

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Education For Pure Science- University Of Thi-qar
Dorsal Hand Vein Image Recognition: A Review
...Show More Authors

Subcutaneous vascularization has become a new solution for identification management over the past few years. Systems based on dorsal hand veins are particularly promising for high-security settings. The dorsal hand vein recognition system comprises the following steps: acquiring images from the database and preprocessing them, locating the region of interest, and extracting and recognizing information from the dorsal hand vein pattern. This paper reviewed several techniques for obtaining the dorsal hand vein area and identifying a person. Therefore, this study just provides a comprehensive review of existing previous theories. This model aims to offer the improvement in the accuracy rate of the system that was shown in previous studies and

... Show More
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Surgical Case Reports
A rare variant of mirror hand deformity
...Show More Authors

Congenital hand and forearm anomalies pose a unique challenge in plastic and pediatric surgery. We present a case report of an 8- months-old girl with a congenital left sided hand and forearm anomaly, provisionally diagnosed as atypical left mirror hand anomaly. Classically there is absence of radius and duplication of ulna; however, our case had normal radius and ulna and a hand with seven digits arranged in two groups. We did a surgery which involved a ray amputation of the finger ulnar to the most radial digit, aiming to preserve an adequate first web space to reconstruct the thumb. The result of the surgical treatment in both functional and cosmetic aspects was, in authors’ opinion, good.