Preferred Language
Articles
/
7oZXT4YBIXToZYALWIFO
stress and strain analysis for the prosthetic hand design actuated by links
...Show More Authors

Prosthetic hands are compensatory devices for the hand amputees as a result of injury, various accidents or birth deformities, types of prosthetic hand vary depending on the mechanism they operate and how they perform. There are common types in use that are characterized by their complex mechanisms, which are difficult for the amputee to use or exclude use because of their high cost, therefore the aim of this research is to design an artificial hand that is suitable in terms of simplicity of use and low cost and similar to a natural hand with regard to dimensions and shape that operated in the mechanism of links. This research involves Stress and strain analysis of the prosthetic hand and its fingers that modelled from (Petg CR) material. All design and analysis are done in the program Solidwork 2018 to find the effect of different load conditions on the designed hand by adding (normal load, ball grasping, cylinder rising). The von- Mises stresses deducted for a fingertip and assembled finger as well as the assembled hand to identify the maximum stress accrues before failure in daily life functions.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu May 05 2022
Journal Name
Al-kindy College Medical Journal
The Role of Strain Elastography in Evaluating Borderline Axillary Lymph nodes
...Show More Authors

Background: Axillary lymph node (ALN) enlargement with diffuse cortical thickening and conserved echogenic hilum may represent a diagnostic and therapeutic challenge. Sonographic strain elastography may help the characterization of borderline ALN. 

Aim: To evaluate the strain elastography of borderline ALN and to calculate a cutoff value of strain ratio (SR) that can identify suspicious ALN with the highest sensitivity and specificity to reduce unnecessary invasive procedures. 

Subjects and Methods: A prospective study included 45 patients who attended the Breast clinic in Oncology Teaching Hospital with borderline axillary lymphadenopathy (intact hilum and diffusely thic

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 30 2023
Journal Name
Journal Of Economics And Administrative Sciences
The Cluster Analysis by Using Nonparametric Cubic B-Spline Modeling for Longitudinal Data
...Show More Authors

Longitudinal data is becoming increasingly common, especially in the medical and economic fields, and various methods have been analyzed and developed to analyze this type of data.

In this research, the focus was on compiling and analyzing this data, as cluster analysis plays an important role in identifying and grouping co-expressed subfiles over time and employing them on the nonparametric smoothing cubic B-spline model, which is characterized by providing continuous first and second derivatives, resulting in a smoother curve with fewer abrupt changes in slope. It is also more flexible and can pick up on more complex patterns and fluctuations in the data.

The longitudinal balanced data profile was compiled into subgroup

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun May 12 2019
Journal Name
Al-khwarizmi Engineering Journal
Motion Control of Three Links Robot Manipulator (Open Chain) with Spherical Wrist
...Show More Authors

Robot manipulator is a multi-input multi-output system with high complex nonlinear dynamics, requiring an advanced controller in order to track a specific trajectory. In this work, forward and inverse kinematics are presented based on Denavit Hartenberg notation to convert the end effector planned path from cartesian space to joint space and vice versa where a cubic spline interpolation is used for trajectory segments to ensure the continuity in velocity and acceleration.  Also, the derived mathematical dynamic model is based on Eular Lagrange energy method to contain the effect of friction and disturbance torques beside the inertia and Coriolis effect. Two types of controller are applied ; the nonlinear computed torque control (CTC

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Pakistan Journal Of Medical And Health Sciences
The Effect of Hand Blood Flow on the Peripheral Fingertip Plethysmographic Waveforms Morphology and Pulse Wave Velocity
...Show More Authors

Photoplethysmography (PPG) is a non-invasive optical technique that employs variations in light absorption produced by alteration in the blood volume in capillaries at the skin during the cardiac cycle. This study aims to understand factors related to PPG morphology; a hand-elevation, the study has modified blood flow to and from the finger was conducted in the laboratory. It is widely established that the position of the limb relative to the heart has an effect on blood flow in arteries and venous. Peripheral digital pulse wave (DPW) signals were obtained from 15 healthy volunteer participants during hand-elevation, and hand-lowering techniques wherein the right hand was lifted and lowered relative to heart level, while the left h

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Fri Sep 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Temperature and Residual Stress Distribution in CO2 Laser Welded Aluminum 6061 Plates Using FEM
...Show More Authors

This paper develops a nonlinear transient three-dimensional heat transfer finite element model and a rate independent three-dimensional deformation model, developed for the CO2 laser welding simulations in Al-6061-T6 alloy. Simulations are performed using an indirect coupled thermal-structural method for the process of welding. Temperature-dependent thermal properties of Al-6061-T6, effect of latent heat of fusion, and the convective and radiative boundary conditions are included in the model. The heat input to the model is assumed to be a Gaussian heat source. The finite element code ANSYS12, along with a few FORTRAN subroutines, are employed to obtain the numerical results. The benefit of the proposed methodology is that it

... Show More
View Publication Preview PDF
Publication Date
Fri Jul 01 2016
Journal Name
Journal Of Economics And Administrative Sciences
The vocational Adjustment of workers according to the analysis of job and design ((Local Research in the technology al information and communication office in the parliament))
...Show More Authors

Abstract

The purpose of the present paper is to light on the relationship between jobs design, analysis and its reflections on reinforcing workers' vocational adjustment. The present paper aims to accomplish cognitive and applied goals, top of which, test of functional analysis ability to have effect upon workers' vocational adjustment via job design directly and indirectly owning to the virtual factor practiced by these practices on the sought organization. The problem of the present paper comes with many, the most important is the of how to bolster and back up worker's technical adjustment through good and accurate design for the job.

Based on this problem and goals as to expla

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Feb 11 2026
Journal Name
University Of Anbar Sport And Physical Education Sciences
Anxiety and its relationship to the performance of the front hand hop followed by an anterior spherical flip with a half lap on the jumping platform
...Show More Authors

View Publication
Publication Date
Wed Dec 01 2021
Journal Name
Bioresource Technology Reports
Biosynthesis of polyhydroxyalkanoate (PHA) by a newly isolated strain Bacillus tequilensis ARY86 using inexpensive carbon source
...Show More Authors

View Publication
Scopus (17)
Crossref (8)
Scopus Crossref
Publication Date
Thu Mar 01 2007
Journal Name
Al-khwarizmi Engineering Journal
An experimental comparative study between polypropylene and laminated lower limb prosthetic socket
...Show More Authors

Most researchers concentrate their studies on the design, stress and pressure distributions of the prosthetic socket. A little attention is considered for the stiffness of the various materials of the prosthetic sockets. Prosthetic laminated sockets in Iraq are costly to be manufactured while polypropylene socket is relatively cheap in comparing with the laminates.

Experimental study is conducted to compare the stiffness of five prosthetic sockets made of different materials. Compression, three point flexural and tensile tests are implemented by the Testometric machine. The laminate sockets give better results in compression than polypropylene. Polypropylene gives good results in bending compared with the laminate sockets. When t

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 15 2023
Journal Name
2023 6th International Conference On Engineering Technology And Its Applications (iiceta)
Methodology for the Design and Programming Methods for a Smart Home
...Show More Authors

View Publication
Scopus Crossref