The present work aims to validate the experimental results of a new test rig built from scratch to evaluate the thermal behavior of the brake system with the numerical results of the transient thermal problem. The work was divided into two parts; in the first part, a three-dimensional finite-element solution of the transient thermal problem using a new developed 3D model of the brake system for the selected vehicle is SAIPA 131, while in the second part, the experimental test rig was built to achieve the necessary tests to find the temperature distribution during the braking process of the brake system. We obtained high agreement between the results of the new test rig with the numerical results based on the developed model of the brake system. It was found in some cases the local zones with extreme heat generated in contacting surfaces due to the non-uniformity of the contact pressure during the braking process, where this phenomenon can be led to an increase in the magnitudes of thermal stresses. It was found that the most significant factor on the level of generated temperatures (heat generation) is the initial vehicle's velocity. Furthermore, it was found that the maximum difference between the experimental and numerical results was not exceeding 6%.
The effect of fiber volume fraction of the carbon fiber on the thermal conductivity of the polymer composite material was studied. Different percentages of carbon fibers were used (5%, 10%, 15%, 20%, and 25%). Specimens were made in two groups for unsaturated polyester as a matrix and carbon fibers, first group has parallel arrangement of fibers and the second group has perpendicular arrangement of fibers on the thermal flow, Lee's disk method was used for testing the specimens. This study showed that the values of the of thermal conductivity of the specimens when the fibers arranged in parallel direction was higher than that when the fibers arranged in the perpendicular direction
 
... Show MoreIn this research ,Undoped Nio and 1%Li doped Nio thin films were deposited utilizing chemical spray pyrolysis on the glass substrates heated (450C). The effects of non-thermal plasma on the structural and optical properties were studied. XRD measurement shows that Nio and Nio:1%Li films were found to be polycrystalline and have cubic structure with a preferred orientation (111). Decreased crystal size after exposure especially at (7) sec. AFM data indicate that the surface roughness average and (RMS) values of the prepared doped films are increasing after exposure to plasma, the transmittance increases after doped samples exposure to plasma, it was found that the energy gap value decreased when doped samples exposure to plasma, also, thickn
... Show MoreThe technical of Flame Thermal Spray had been used in producing a cermet
composite based on powders of stabilized zirconium oxide containing amount of
Yatteria oxide (ZrO2- 8Y2O3) reiforced by minerals powders of bonding material
(Ni-Cr- Al- Y) in different rates of additions (25, 35, 50) on stainless steel base type
(304) after preparing it by the way of Grit Blasting.
Before heat treatment, the coated cermet layers were characterized for porosity
and electric resistivity. All samples were heat treated in vacuum furnace at different
temperature and times. The physical tests had been operated after heat treatment
and gave best results especially porosity, which found to be reduced dramatically
and producing hig
The work was carried out in two stages. The first stage concerned
with study of silicon carbide (SiC) ratio (1.5, 2.5, 3.5, and 4.5 wt%)
effect on the Thermal conductivity of polyvinyl chloride (PVC); and
the second stage concerned with the UV – weatherizing (25, 50, and
75 hr), thermal aging (40, 50, and 60 °C), and rain- weatherizing (1,
2.5, and 4 hr) effect on the samples involved. Thermal conductivity
results proved that there was slight increase in thermal conductivity
by (SiC) loading; it increased from 0.17 W/m.K for PVC to 0.19
W/m.K for 4.5% SiC/PVC; where as it was systematically decreased
by UV- weatherizing, thermal aging, and rain- weatherizing. This
property is in a good agreement with gene
This study investigates the influence of phosphoric acid (H3PO4) molarity (2 M, 4 M, and 6 M) on the structural, thermal, optical, and electrical properties of polyvinyl alcohol (PVA)/20% graphene oxide (GO) composite films. X-ray diffraction analysis revealed a semi-crystalline nature for PVA, with characteristic peaks at 19.7 degrees and 42 degrees, and crystalline peaks for GO at 10.1 degrees and 39.8 degrees. The addition of H3PO4 to the PVA/GO composite resulted in the disappearance of GO crystalline peaks, suggesting reduced crystallinity. Differential scanning calorimetry revealed a reduction in both glass transition and melting temperatures as H3PO4 concentration increased. Pure PVA exhibited Tg and Tm values of 68.9 degrees C and 1
... Show MoreThe study aims to make an in-depth analysis and the financial account components in the Iraqi balance of payments because it reflects the economic center of the country towards outside world, it also helps in making decision about monetary and financial policies, finance and foreign Trade the importance of FDI for Iraq lies as an important sources as wells provides advanced technology and job chances, It also avoids the country negative effects of borrowing processes from abroad . for analyzing direct and indirect foreign investment on the balance of payments and financial account in a period between (2003 to 2015), a community and research sample have been selected, presented in CBI/ Balance of payments. Department,
... Show MoreThis study aims to the little impact of accounting financial performance (AFP) analysis on the money market in the Iraqi economy. Potentially limiting future market activity could be international risks and obstacles, which in turn could cause issues and crises (Shah & Jan, 2014; Bakhtiyarovich, 2020). The study concept was inspired by the recognition that there must be communication between the importance of the AFP analysis of the Iraqi securities market and the country’s financial and economic institutions. The sample of the study included ten Iraqi banks listed in the Iraq Stock Exchange (ISE) for the period 2010–2020. The three mathematical models included in the statistical analysis served as the basis for projectin
... Show MoreThe external shocks are one of the phenomena that the Iraqi economy is exposed to over a period of time. It is referred to as changes and events that come from outside the economic system and extends to many economic variables. However, foreign direct investment may be severely affected due to the extreme sensitivity to changes and local and international developments. This type of trauma and its characteristics to help manage and cope with external shocks, and in order to avoid the standard problems experienced by some models of simple linear regression, multi-linear regression models were used with variables Scientific and other dummy variables .
The study foun
... Show MoreIntroduction/Aim. Seminal fluid analysis (SFA) plays a crucial role in helping infertility clinics diagnose the underlying reason of male infertility. The aim of the study was to investigate seminal fluid patterns of male partners of an infertile couple with apparently fertile female partners. Materials and methods. A cross-sectional study was conducted between January 2019 and December 2022. Patients were attending consultations for delayed conception for more than 12 months with apparently fertile female partner. Results. Four hundred fifty-three patients were included in the study. The distribution of patients according to age groups showed that 277 patients were young, aged 21 - 30 years (61%). Two hundred sixty-two (58%) patien
... Show MoreA numerical simulation is made on the thermal lensing effect in an laser diode end-pumped Nd:YAG laser rod. Based on finite element method (FEM), the laser rod temperature distribution is calculated and the focal length is deduced for a Gaussian and super-Gaussian pump beam profiles.
At the pump power of 20W, the highest temperature located at the center of end-pumped face was 345K, and the thermal lens focal length was 81.4mm along the x-z axis.
The results indicate that the thermal lensing effect sensitively depend on the pump power, waist radius of the pump beam and the pump distribution in a laser rod geometry.