In this work the parameters of plasma (electron temperature Te,
electron density ne, electron velocity and ion velocity) have been
studied by using the spectrometer that collect the spectrum of
plasma. Two cathodes were used (Si:Si) P-type and deposited on
glass. In this research argon gas has been used at various values of
pressures (0.5, 0.4, 0.3, and 0.2 torr) with constant deposition time
4 hrs. The results of electron temperature were (31596.19, 31099.77,
26020.14 and 25372.64) kelvin, and electron density (7.60*1016,
8.16*1016, 6.82*1016 and 7.11*1016) m-3. Optical properties of Si
were determined through the optical transmission method using
ultraviolet visible spectrophotometer with in the range
(
Background: During pregnancy many physiological, anatomical and biochemical changes take place that affect almost all body systems. In the oral pregnant women have serious changes such as more sever dental caries. This study was conducted to measure dental caries severity and selected salivary variables (salivary flow rate, PH and viscosity)and to find the relation of dental caries with these salivary variables. Subjects, materials and methods: The study group consisted of 60 pregnant women that were divided into three equal groups according to trimester (20 pregnant women in each trimester).They were selected randomly from the Maternal and Child Health Care Centers in Baghdad city, the age range was 20-25 years. In addition to 20 unmarried
... Show MoreExperimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre
... Show More
Background Many antidiabetic medications with distinct modes of action are available, The sodium glucose cotransporter-2 (SGLT-2) inhibitors are among the most recent oral antihyperglycemic medications. The American Diabetes Association recommends metformin, a biguanide medication, as the first option for oral control of type 2 diabetes because it has demonstrated promise in this regard. Aim of the study To evaluate and compare the effects of metformin and SGLT-2 inhibitors on general urine parameters in T2DM patients from Iraq. Method a prospective cohort study where 101 adult patients of both sexes aged under 70 years and newly diagnosed with T2DM, patients were divided into two groups, Metformin group (n=52), where metformin was p
... Show MoreNumerical simulation of charge density produced in plasma actuators is dependent upon the development of models dealing with electrical properties. The main aim of this work is to investigate the characteristics surface charge density and space charge density of DBD plasma actuator. A simple design of surface dielectric barrier discharge plasma actuator is used in the study. The discharge gas was N2:H2 mixture with applied voltage equal to 1.5 kV. A theoretical plasma model is used to establish the charge density details. Results show that surface charge density increased in value and spread in width alone the exposed electrode as the voltage increased and reached to the amplitude value.