Helicobacter pylori (HP) colonizes the gastric mucosa and causes gastric and extra-gastric disorders. Several liver diseases, such as Non-alcoholic fatty liver disease, seem to be caused by the gastrointestinal tract, which is primarily determined by the presence of bacteria like Helicobacter pylori. The study aims to evaluate the relationship between Helicobacter pylori infection and liver diseases by measuring liver enzymes, inflammatory markers, and hematological parameters among patients with gastritis and without Helicobacter pylori infection. A total of 1,325 patients who had gastritis diagnosed by gastroscopy were included in our study. They were divided into the HP– group (340 women, 323 men) and the HP+ group (330 women, 332 men). A control group (360 women, 260 men) without gastritis or HP infection was included in this study. HP was determined using the 13C urea breath test, which requires patients to swallow a capsule with water. Measurements of liver enzymes and complete blood cell counts were done in addition to interleukin-6(IL-6) and C-reactive protein (CRP). The results showed a significant increase in IL-6 and CRP in the HP+ group. Additionally, the mean levels of leukocytes and platelets were significantly increased in the HP+ group, but liver enzymes were within the normal range in both the HP+ & HP– groups. Although Helicobacter pylori causes elevation of indices of systemic inflammation, the liver did not show evidence of fatty infiltration, as liver enzymes were within normal limits.
As a reservoir is depleted due to production, pore pressure decreases leading to increased effective stress which causes a reduction in permeability, porosity, and possible pore collapse or compaction. Permeability is a key factor in tight reservoir development; therefore, understanding the loss of permeability in these reservoirs due to depletion is vital for effective reservoir management. The paper presents a case history on a tight carbonate reservoir in Iraq which demonstrates the behavior of rock permeability and porosity as a function of increasing effective stress simulating a depleting mode over given production time. The experimental results show unique models for the decline of permeability and porosity as function effective str
... Show MoreThis case series aims to evaluate patients affected with post COVID‐19 mucormycosis from clinical presentation to surgical and pharmacological treatment to improve the disease prognosis.
This case series was conducted at a specialized surgery hospital in Baghdad Medical City for over 10 months. Fifteen cases who had mild to severe COVID‐19 infections followed by symptoms similar to aggressive periodontitis, such as mobility and bone resorption around the multiple maxillary teeth, were included in this case series.
Industrial wastewater containing nickel, lead, and copper can be produced by many industries. The reverse osmosis (RO) membrane technologies are very efficient for the treatment of industrial wastewater containing nickel, lead, and copper ions to reduce water consumption and preserving the environment. Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50 to 200 ppm), pressures (1 to 4 bar), temperatures (10 to 40 oC), pH (2 to 5.5), and flow rates (10 to 40 L/hr), were prepared and subjected to treatment by RO system in the laboratory. The results showed that high removal efficiency of the heavy metals could be achieved by RO process (98.5%, 97.5% and 96% for Ni(II),
... Show MoreThe removal of boron from aqueous solution was carried out by electrocoagulation (EC) using magnesium electrodes as anode and stainless steel electrodes as cathode. Several operating parameters on the removal efficiency of boron were investigated, such as initial pH, current density, initial boron ion concentration, NaCl concentration, spacing between electrodes, electrode material, and presence of carbonate concentration. The optimum removal efficiency of 91. 5 % was achieved at a current density of 3 mA/cm² and pH = 7 using (Mg/St. St. ) electrodes, within 45 min of operating time. The concentration of NaCl was o. 1 g/l with a 0.5cm spacing between the electrodes. First and second order rate equation were applied to study adsorp
... Show MoreThe world's population growth and the increasing demand for new infrastructure facilities and buildings , present us with the vision of a higher resources consumption, specially in the form of more durable concrete such as High Performance Concrete (HPC) . Moreover , the growth of the world pollution by plastic waste has been tremendous. The aim of this research is to investigate the change in mechanical properties of HPC with added waste plastics in concrete. For this purpose 2.5%, 5% and 7.5% in volume of natural fine aggregate in the HPC mixes were replaced by an equal volume of Polyethylene Terephthalate (PET) waste , got by shredded PET bottles. The mechanical propert
... Show MoreIraqi siliceous rocks were chosen to be used as raw materials in this study which is concern with the linear shrinkage and their related parameters. They are porcelinite from Safra area (western desert) and Kaolin Duekla, their powders were mixed in certain percentage, to shape compacts and sintered. The study followed with thermal and chemical treatments, which are calcination and acid washing. The effects on final compact properties such as linear shrinkage were studied. Linear shrinkage was calculated for sintered compacts to study the effects of calcination processes, chemical washing, weight percentage, sintering processes, loading moment were studied on this property where the compacts for groups is insulating materials.
Linear
The presence of dyes in wastewater has become a major issue all over the world. The discharge of dyes in the environment is concerned for both toxicological and esthetical reasons. In this study, the removal of dyes from aqueous solution by electrocoagulation using aluminum electrodes as cathode and anode were investigated with the electrocoagulation cell of 1litter. The study included: the impact of various operating parameters on the dyes removal efficiency like pH, NaCl concentration, distance between electrodes, voltage, initial dyes concentration and type of electrodes. The dye (congo red) concentrations were (50, 100, 150, and 200 ppm), stirring speed was 120 rpm at room temperature. pH used was maintained constant
... Show MoreMedia is one of the main and effective factors; and it is a tool of crisis management equipment. Media is one of the most dangerous, effective and decisive weapons in modern conflicts; a tool for making events and influencing their events and trends as a means of reporting as the enormous capabilities of media which help media to move very quickly, and cross borders; and overcome obstacles, through many means of audio, reading and visual. As its ability, moreover, to influence the psychological and intellectual control of communities, and behaviors.
Intelligent media is, then, used in crises management and coverage. Crises have been existed with the presence of man on Earth. Thei
... Show More