Preferred Language
Articles
/
7BeIbI4BVTCNdQwCcEc8
New application of eco-friendly biosorbent giant reed for removal of reactive dyes from water followed by sustainable path for recycling the dyes-loaded sludge in concrete mixes
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Mar 30 2021
Journal Name
International Journal Of Pharmaceutical Research
Eco-friendly and Efficient Composition, Diagnosis Theoretical, kinetic studies, Antibacterial and Anticancer Activities of Mixed Some Metal Complexes of Tridentate Schiff base Ligand
...Show More Authors

View Publication
Crossref
Publication Date
Sun Mar 01 2020
Journal Name
International Journal Of Pharmaceutical Research
Eco-friendly and Efficient Composition, Diagnosis Theoretical, kinetic studies, Antibacterial and Anticancer Activities of Mixed Some Metal Complexes of Tridentate Schiff base Ligand
...Show More Authors

Abstract: Mixed ligand Mn(II), Co(II), Ni(II), Cu (II), Zn(II), and Cd(II) complexes with (TMAP) Schiff base ligand and (8HQ) have been composition and analyzed. Diagnosis by, melting point, solubility, Electronic, mass and IR-spectroscopic studies, conductivity elemental, thermoanalytical analysis displayed the forming of mononuclear complexes. Spectral studies results suggest an octahedral system or the metal (II) mixed complexes. The detainments of molar conductance of the mixed complexes in DMF coincide to electrolytic nature of the mixed complexes, consequently, these complexes could be subedited as [M(TMAP)(8Q)(H2O)]nX.yH2O (M=Co(II) and Cu(II) complexes(where n = 1, y = 0 ); [M(TMAP)(8Q)(H2O)]nX.yH2O (M = (where n = 1, y = 1 for Ni(

... Show More
Publication Date
Tue Sep 02 2025
Journal Name
Journal Of Composites Science
Numerical Evaluation of Embedded I-Section Strengthening in Axially Loaded Composite Concrete-Filled Stainless Steel Tubes
...Show More Authors

To enhance the structural performance of concrete-filled steel tube (CFST) columns, various strengthening techniques have been proposed, including the use of internal steel stiffeners, external wrapping with carbon fiber-reinforced polymer (CFRP) sheets, and embedded steel elements. However, the behavior of concrete-filled stainless-steel tube (CFSST) columns remains insufficiently explored. This study numerically investigates the axial performance of square CFSST columns internally strengthened with embedded I-section steel profiles under biaxial eccentric loading. Finite element (FE) simulations were conducted using ABAQUS v. 6.2, and the developed models were validated against experimental results from the literature. A comprehen

... Show More
View Publication
Scopus Clarivate Crossref
Publication Date
Mon Jun 04 2018
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Darifenacin Hydrobromide loaded nanostructured lipid carrier for oral administration
...Show More Authors

Darifenacin hydrobromide is a selective ?3 receptor antimuscarinic drug and it is used in the management of urinary frequency, urgency, and incontinence in detrusor instability. It slightly soluble in water, undergoes extensive hepatic first-pass metabolism and has short elimination half-life (3–4 hours). Therefore, It has low bioavailability (15.4 % - 18.6 %). Darifenacin hydrobromide loaded NLCs were formulated by emulsification sonication using different ratios of solid lipid to liquid lipid, different types of surfactants, and different concentration of surfactants. Formula sixteen was considered as an optimized formula based on its particle size, PDI, zeta potential and entrapment efficiency. Formula sixteen subjected t

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (1)
Scopus Crossref
Publication Date
Sun Dec 01 2024
Journal Name
Journal Of Molecular Liquids
Application of ionic liquids as co-solvent for oil extraction from desert date
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Application of SWAT Model for Sediment Loads from Valleys Transmitted to Haditha Reservoir
...Show More Authors

This study included the extraction properties of spatial and morphological basins studied using the Soil and Water Assessment Tool (SWAT) model linked to (GIS) to find the amount of sediment and rates of flow that flows into the Haditha reservoir . The aim of this study is determine the amount of sediment coming from the valleys and flowing into the Haditha Dam reservoir for 25 years ago for the period (1985-2010) and its impact on design lifetime of the Haditha Dam reservoir and to determine the best ways to reduce the sediment transport. The result indicated that total amount of sediment coming from all valleys about (2.56 * 106 ton). The maximum annual total sediment load was about (488.22 * 103 ton) in year 1988

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Heavy Metals from Industrial Wastewater by Using RO Membrane
...Show More Authors

Industrial wastewater containing nickel, lead, and copper can be produced by many industries. The reverse osmosis (RO) membrane technologies are very efficient for the treatment of industrial wastewater containing nickel, lead, and copper ions to reduce water consumption and preserving the environment. Synthetic industrial wastewater samples containing Ni(II), Pb(II), and Cu(II) ions at various concentrations (50 to 200 ppm), pressures (1 to 4 bar), temperatures (10 to 40 oC), pH (2 to 5.5), and flow rates (10 to 40 L/hr), were prepared and subjected to treatment by RO system in the laboratory. The results showed that high removal efficiency of the heavy metals could be achieved by RO process (98.5%, 97.5% and 96% for Ni(II),

... Show More
View Publication Preview PDF
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Removal of 4-Chlorophenoles from Simulated Wastewater by Advanced Oxidation Processes
...Show More Authors

The degradation and mineralization of 4-chlorophenol (4-CP) by advanced oxidation processes (AOPs) was investigated in this work, using both of UV/H2O2 and photo-Fenton UV/H2O2/Fe+3 systems.The reaction was influenced by the input concentration of H2O2, the amount of the iron catalyst, the type of iron salt, the pH and the concentration of 4-CP. A colored solution of benzoquinon can be observed through the first 5 minutes of irradiation time for UV/H2O2 system when low concentration (0.01mol/L) of H2O2 was used. The colored solution of benzoquinon could also be observed through the first 5 minutes for the UV/H2O2/Fe+3 system at high
concentration (100ppm) of 4-CP. The results have shown that adding Fe+3 to the UV/H2O2 system enhanced

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Dec 30 2020
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Acetaminophen Residues from Wastewater by Bulk Liquid Membrane Process
...Show More Authors

   The removal of Anit-Inflammatory drugs, namely; Acetaminophen (ACTP), from wastewater by bulk liquid membrane (BLM) process using Aliquat 336 (QCl) as a carrier was investigated. The effects of several parameters on the extraction efficiency were studied in this research, such as the initial feed phase concentration (10-50) ppm of ACTP, stripping phase (NaCl) concentration (0.3,0.5,0.7 M), temperature (30-50oC), the volume ratio of feed phase to membrane phase (200-400ml/80ml), agitation speed of the feed phase (75-125 rpm), membrane stirring speed (0, 100, 150 rpm), carrier concentration (1, 5, 9 wt%), the pH of feed (2, 4, 6, 8, 10), and solvent type (CCl4 and n-Heptane). The study shows that high ext

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Tue May 23 2023
Journal Name
Journal Of Engineering
REMOVAL OF OIL FROM WASTEWATER BY ADVANCED OXIDATION PROCESS / HOMOGENEOUS PROCESS
...Show More Authors

In the present work advanced oxidation process, photo-Fenton (UV/H2O2/Fe+2) system, for the treatment of wastewater contaminated with oil was investigated. The reaction was influenced by the input concentration of hydrogen peroxide H2O2, the initial amount of the iron catalyst Fe+2, pH, temperature and the concentration of oil in the wastewater. The removal efficiency for the system UV/ H2O2/Fe+2 at the optimal conditions and dosage (H2O2 = 400mg/L, Fe+2 = 40mg/L, pH=3, temperature =30o C) for 1000mg/L load was found to be 72%.

View Publication Preview PDF
Crossref (12)
Crossref