Forty lower premolars with single root canals prepared with ProtaperNext files to size 25, and obturated with GP/sealer using lateral compaction. Teeth divided randomly into four groups (group n=10). Protaper universal retreatment kit (PUR), D-Race desobturation files (DRD), R-Endo retreatment kit (RE) and Hedstrom (H) files (control) were used to remove GP/sealer in each group. Removal effectiveness assessed by measuring the GP /sealer remnants in the roots after sectioning them into two halves. Stereomicroscope with a digital camera used to capture digital images. Images processed by ImageJ software to measure the percentage of GP/sealer remnants surface area in total, coronal, middle and apical areas of the canal. In the coronal area, PUR had significantly lower R% than RE and H groups, respectively (p<0.05). Also, DRD had significantly lower R% than RE (P<0.05). There was no significant difference between PUR and DRD (p>0.05), as well as no significant difference between RE and H groups(p>0.05). In the middle, apical and total root areas, Both PUR and DRD had significantly lower R% than RE and H groups, respectively (p<0.05). There was no significant difference between PUR and DRD (p>0.05). Also, there was no significant difference in R% between RE and H groups (p>0.05).
Police play an important role in any society. Where they maintain public order by stopping and deterring crime and bringing criminals to justice. In order to achieve these objectives, they have certain means of law (search, arrest, use of force that may be lethal in some cases). However, such means may be misused in a way that harms members of society such as (Exceeding the Scope of a search warrant, violation of privacy of individuals, False Imprisonment, Excessive use of force, Sudden Deaths in custody, Sexual Assault and Harassment, Failure to respond for Domestic violence calls), which raises the civil liability of police officers and their agencies for such damage. Police officers may even abuse their characteristics even outside offic
... Show MoreThe other day in the Holy Quran and the four Gospels
|
Background: Drawing blood to measure total serum bilirubin is painful & time consuming. Transcutaneous bilirubinometer working by multiwavelength spectral reflectance from the skin surface on forehead or upper sternum is a quick & painless technique. Objectives: to compare the effectiveness of transcutaneous (over the upper sternum and forehead) and serum bilirubin measurement of neonate with jaundice. Subjects and Methods: This is a cross sectional prospective study. It enrolled 175 jaundiced neonates & excluded those exposed to phototherapy. It was conducted at Child Central Teaching Hospi |
The building of the Babylonian theater is considered as one of the distinctive buildings where its foundations have remained steadfast in the face of geographical changes, social's erosion and groundwater that threatened almost all traces of Babylon despite the destruction of the outer structure of the building. The general directorate of antiques performed prospection for those foundations (the ground map), and then the building was completed by new bricks over the original scheme. It became clear when examining the building; its components and foundations, that the building is unique in comparison with the old buildings of the world throughout Iraq. There are similar buildings in other places like Jordan and North Africa such as
The electrocardiogram (ECG) is the recording of the electrical potential of the heart versus time. The analysis of ECG signals has been widely used in cardiac pathology to detect heart disease. The ECGs are non-stationary signals which are often contaminated by different types of noises from different sources. In this study, simulated noise models were proposed for the power-line interference (PLI), electromyogram (EMG) noise, base line wander (BW), white Gaussian noise (WGN) and composite noise. For suppressing noises and extracting the efficient morphology of an ECG signal, various processing techniques have been recently proposed. In this paper, wavelet transform (WT) is performed for noisy ECG signals. The graphical user interface (GUI)
... Show More