Background: Legionella pneumophila (L. pneumophila) is gram-negative bacterium, which causes Legionnaires’ disease as well as Pontiac fever. Objective: To determine the frequency of Legionella pneumophila in pneumonic patients, to determine the clinical utility of diagnosing Legionella pneumonia by urinary antigen testing (LPUAT) in terms of sensitivity and specificity, to compares the results obtained from patients by urinary antigen test with q Real Time PCR (RT PCR) using serum samples and to determine the frequency of serogroup 1 and other serogroups of L. pneumophila. Methods: A total of 100 pneumonic patients (community acquired pneumonia) were enrolled in this study during a period between October 2016 to April 2017; 92 samples were collected from patients attended and admitted to Al-Imamein Al-Kadhimein Medical City and 8 samples from those in the (Center of Kidney Diseases and Transplantation) in the Medical City of Baghdad. All patients were under therapy with antibiotics. Serum and urine specimens were obtained from all patients; urine samples were processed for urinary antigen test (rapid test). Serum samples were collected and submitted to DNA extraction for detection of L. pneumophila mip gene by q RT PCR assay. Results: The percentage of L. pneumophila in two hospitals in Bagdad was 30%. Of these 26% was serogroup 1 detected by urinary antigen testing (UAT). In the other hand, 23% of samples were positive by q RT PCR based mip gene, of these 19 % were serogroup 1 and 4% were another serogroup. The sensitivity of UAT is high (P value < 0.001), which means statistically highly significance than q RT PCR. Conclusion: LPUAT is a rapid tool for early diagnosis of Legionella infection, which highlights the need of using this test in hospitals and health institutions and there is a high prevalence of L. pneumophila in Iraq that refer to the necessity of considering this microorganism point of view in future studies for detection and treatment in pneumonic patients. Keywords: L. pneumophila, mip gene, quantitative real time PCR, urinary antigen. Citation: Gauad SA, Abdulrahman TR, Muhamad AK, Jawad AA, Hassan JS. Clinical utility of urinary antigen test and molecular method for detection of Legionella pneumophila. Iraqi JMS. 2018; 16(2): 207-215. doi: 10.22578/IJMS.16.2.13
Background: Listeria monocytogenes, a member of the genus Listeria, is widely distributed in agricultural environments, such as soil, manure and water. The genus of Listeria bacteria is about 15-17 species. It is a pathogenic bacterium that can cause a rare but dangerous infection called listeriosis.
Objectives: Studying the rate of salads contaminated with Listeria bacteria. and Listeria monocytogenes according to International, Arabic and Iraqi specifications and finding the correlation between commitments of restaurants to standard health conditions with contamination with these bacteria
Methods: The study included
... Show MoreThe role of relaxation program for reducing anxiety of patients in dental clinic
هدف البحث إلى التعرف على مستوى الثقافة الغذائية الرياضية لدى عدائي مسافات ركض (400 و800) و(400) متر حواجز الشباب، والتعرف على العلاقة وإسهام وأثر الثقافة الغذائية الرياضية ببعض المؤشرات البيوكيميائية لدى عدائي مسافات ركض (400 و800) و(400) متر حواجز الشباب، أعتمد المنهج الوصفي بأسلوب العلاقات الإرتباطية، و تمثلت حدود مجتمع البحث بالعدائين الشباب لفعاليات ركض (400 و800) و(400) متر حواجز، يمثلون لاعبي الأندية العراقية الب
... Show MoreIn this research, optical communication coding systems are designed and constructed by utilizing Frequency Shift Code (FSC) technique. Calculations of the system quality represented by signal to noise ratio (S/N), Bit Error Rate (BER),and Power budget are done. In FSC system, the data of Nonreturn- to–zero (NRZ ) with bit rate at 190 kb/s was entered into FSC encoder circuit in transmitter unit. This data modulates the laser source HFCT-5205 with wavelength at 1310 nm by Intensity Modulation (IM) method, then this data is transferred through Single Mode (SM) optical fiber. The recovery of the NRZ is achieved using decoder circuit in receiver unit. The calculations of BER and S/N for FSC system a
... Show MoreTraction force and power requirement when performing primary tillage occupy the minds of almost farmers, this field research had aim to determine and calculate the pulling force of the most commonly used moldboard and chisel plows, the research conducted in silt clay loam for chisel and moldboard plows as the main factor, two depths of tillage 18 and 25 cm as a second factor and three speeds of tractor 2.55, 4.30 and 6.15 km.h-1 as a third factor. Moldboard plow recorded least traction force 7.550 kN, drawbar power 11.583 hp, power losses due to slippage 1.088 hp, power on the rear axle of the tractor 15.770 hp and brake horse power 17.495 hp. Chisel plow recorded best traction efficiency 76.217 % and total traction efficiency 68.659 %. Dep
... Show MoreIn this paper, three approximate methods namely the Bernoulli, the Bernstein, and the shifted Legendre polynomials operational matrices are presented to solve two important nonlinear ordinary differential equations that appeared in engineering and applied science. The Riccati and the Darcy-Brinkman-Forchheimer moment equations are solved and the approximate solutions are obtained. The methods are summarized by converting the nonlinear differential equations into a nonlinear system of algebraic equations that is solved using Mathematica®12. The efficiency of these methods was investigated by calculating the root mean square error (RMS) and the maximum error remainder (𝑀𝐸𝑅n) and it was found that the accuracy increases with increasi
... Show More