Background: Legionella pneumophila (L. pneumophila) is gram-negative bacterium, which causes Legionnaires’ disease as well as Pontiac fever. Objective: To determine the frequency of Legionella pneumophila in pneumonic patients, to determine the clinical utility of diagnosing Legionella pneumonia by urinary antigen testing (LPUAT) in terms of sensitivity and specificity, to compares the results obtained from patients by urinary antigen test with q Real Time PCR (RT PCR) using serum samples and to determine the frequency of serogroup 1 and other serogroups of L. pneumophila. Methods: A total of 100 pneumonic patients (community acquired pneumonia) were enrolled in this study during a period between October 2016 to April 2017; 92 samples were collected from patients attended and admitted to Al-Imamein Al-Kadhimein Medical City and 8 samples from those in the (Center of Kidney Diseases and Transplantation) in the Medical City of Baghdad. All patients were under therapy with antibiotics. Serum and urine specimens were obtained from all patients; urine samples were processed for urinary antigen test (rapid test). Serum samples were collected and submitted to DNA extraction for detection of L. pneumophila mip gene by q RT PCR assay. Results: The percentage of L. pneumophila in two hospitals in Bagdad was 30%. Of these 26% was serogroup 1 detected by urinary antigen testing (UAT). In the other hand, 23% of samples were positive by q RT PCR based mip gene, of these 19 % were serogroup 1 and 4% were another serogroup. The sensitivity of UAT is high (P value < 0.001), which means statistically highly significance than q RT PCR. Conclusion: LPUAT is a rapid tool for early diagnosis of Legionella infection, which highlights the need of using this test in hospitals and health institutions and there is a high prevalence of L. pneumophila in Iraq that refer to the necessity of considering this microorganism point of view in future studies for detection and treatment in pneumonic patients. Keywords: L. pneumophila, mip gene, quantitative real time PCR, urinary antigen. Citation: Gauad SA, Abdulrahman TR, Muhamad AK, Jawad AA, Hassan JS. Clinical utility of urinary antigen test and molecular method for detection of Legionella pneumophila. Iraqi JMS. 2018; 16(2): 207-215. doi: 10.22578/IJMS.16.2.13
Greywater is a possible water source that can be improved for meeting the quality required for irrigation. Treatment of greywater can range from uncomplicated coarse filtration to advanced biological treatment. This article presents a simple design of a small scale greywater treatment plant, which is a series of physical and natural processes including screening, aeration, sedimentation, and filtration using granular activated carbon filter and differentiates its performance with sand filter. The performance of these units with the dual filter media of (activated carbon with sand) in treatment of greywater from Iraqi house in Baghdad city during 2019 and that collected from several points including washbasins, kitchen si
... Show MoreResin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This
Lead-acid batteries have been used increasingly in recent years in solar power systems, especially in homes and small businesses, due to their cheapness and advanced development in manufacturing them. However, these batteries have low voltages and low capacities, to increase voltage and capacities, they need to be connected in series and parallel. Whether they are connected in series or parallel, their voltages and capacities must be equal otherwise the quality of service will be degraded. The fact that these different voltages are inherent in their manufacturing, but these unbalanced voltages can be controlled. Using a switched capacitor is a method that was used in many methods for balancing voltages, but their respons
... Show MoreAn experimental study on a KIA pride (SAIPA 131) car model with scale of 1:14 in the wind tunnel was made beside the real car tests. Some of the modifications to passive flow control which are (vortex generator, spoiler and slice diffuser) were added to the car to reduce the drag force which its undesirable characteristic that increase fuel consumption and exhaust toxic gases. Two types of calculations were used to determine the drag force acting on the car body. Firstly, is by the integrating the values of pressure recorded along the pressure taps (for the wind tunnel and the real car testing), secondly, is by using one component balance device (wind tunnel testing) to measure the force. The results show that, the avera
... Show MoreBac kground:: Multidrug resistant methicillin-resistant Staphylococcus aureus (MRSA) is a major cause of nosocomial and community acquired infections. The glycopeptides vancomycin has been proposed as the drug of choice for treating such infections; this lead to the emergence of vancomycin intermediate sensitive S. aureus (VISA) and vancomycin resistant S.aureus (VRSA).
Objjec tt iiv es :: To identify the vancomycin resistance both phenotypically and genotypically among MRSA isolates from different hospitals and to determine the sensitivity of these isolates to different antimicrobial agents
Metthods:: A total of 204 S. aureus isolates were obtained randomly from various clinical specimens including (wound swab, burn swab, ear swab
Background: Reliable detection the etiological agent of amoebic dysentery and extra-intestinal amoebiasis have Public health importance specially in asymptomatic human and animals, Since the acquisition of pet dogs in the recent period has become widespread in our city. Aim: To give correct perception of infection rate in asymptomatic individuals (human and domestic dogs) for the first aspect and about detection and diagnosis of the pathogenic species of Entamoeba histolytica from another morphologically similar and commensal one using the molecular technique in stool samples of asymptomatic individuals the second aspect. Methods: During the study period from the beginning of September 2020 to the end of February 2021, a total of 95 stool s
... Show MoreThe aim of the research is to diagnose and analyze the gap between the actual reality and the application of the eighth requirement (operation) in the National Insurance Company in accordance with the international standard specification for the quality management system (ISO 9001:2015), which is related to the planning, implementation and control of operations, which would raise the level of performance of employees and be reflected in the provision of An appropriate service for the faithful, as the reality of the condition of the requirement was studied by identifying the strengths and weaknesses of the system to diagnose the gap and find ways to address it. A workshop was held with company officials, through which questions were raise
... Show More