Background: Legionella pneumophila (L. pneumophila) is gram-negative bacterium, which causes Legionnaires’ disease as well as Pontiac fever. Objective: To determine the frequency of Legionella pneumophila in pneumonic patients, to determine the clinical utility of diagnosing Legionella pneumonia by urinary antigen testing (LPUAT) in terms of sensitivity and specificity, to compares the results obtained from patients by urinary antigen test with q Real Time PCR (RT PCR) using serum samples and to determine the frequency of serogroup 1 and other serogroups of L. pneumophila. Methods: A total of 100 pneumonic patients (community acquired pneumonia) were enrolled in this study during a period between October 2016 to April 2017; 92 samples were collected from patients attended and admitted to Al-Imamein Al-Kadhimein Medical City and 8 samples from those in the (Center of Kidney Diseases and Transplantation) in the Medical City of Baghdad. All patients were under therapy with antibiotics. Serum and urine specimens were obtained from all patients; urine samples were processed for urinary antigen test (rapid test). Serum samples were collected and submitted to DNA extraction for detection of L. pneumophila mip gene by q RT PCR assay. Results: The percentage of L. pneumophila in two hospitals in Bagdad was 30%. Of these 26% was serogroup 1 detected by urinary antigen testing (UAT). In the other hand, 23% of samples were positive by q RT PCR based mip gene, of these 19 % were serogroup 1 and 4% were another serogroup. The sensitivity of UAT is high (P value < 0.001), which means statistically highly significance than q RT PCR. Conclusion: LPUAT is a rapid tool for early diagnosis of Legionella infection, which highlights the need of using this test in hospitals and health institutions and there is a high prevalence of L. pneumophila in Iraq that refer to the necessity of considering this microorganism point of view in future studies for detection and treatment in pneumonic patients. Keywords: L. pneumophila, mip gene, quantitative real time PCR, urinary antigen. Citation: Gauad SA, Abdulrahman TR, Muhamad AK, Jawad AA, Hassan JS. Clinical utility of urinary antigen test and molecular method for detection of Legionella pneumophila. Iraqi JMS. 2018; 16(2): 207-215. doi: 10.22578/IJMS.16.2.13
Simple, rapid and sensitive spectrophotometric method was proposed for the analysis of metoclopramide hydrochloride (MPH) in pure form as well as in pharmaceutical tablets. The method is based on the diazotization reaction of MPH with sodium nitrite in hydrochloric acid medium to form diazonium salt, which is coupled with 1-naphthol in sodium hydroxide medium to form azo dye, showing absorption maxima at 550 nm. Beer’s law is obeyed in the concentration range of 0.4 – 18 µg mL-1 of MPH with detection limit 0.5448 µg mL-1. The molar absorptivity and Sandell’s sensitivity are 3.4969 × 104 L mol-1 cm-1 and 0.0101 µg cm-2, respectively. The method was successfully applied to the determination of MPH in pharmaceutical tablets with
... Show MoreIn this paper, split-plate airlift electrochemical reactor as an apparatus with new configuration for wastewater treatment was provided. Two aluminum plates were fixed inside the reactor and present two functions; first it works as split plates for internal loop generation of the airlift system (the zone between the two plates acts as riser while the other two zones act as downcomer) and second it works as two electrodes for electrocoagulation process. Simulated wastewater contaminated with zinc ions was used to test the performance of this apparatus for zinc removal by studying the effect of different experimental variables such as initial concentration of zinc (50-800 ppm), electrical current density (2.67-21.4 mA/cm2), init
... Show MoreAbstract:
This research aims to compare Bayesian Method and Full Maximum Likelihood to estimate hierarchical Poisson regression model.
The comparison was done by simulation using different sample sizes (n = 30, 60, 120) and different Frequencies (r = 1000, 5000) for the experiments as was the adoption of the Mean Square Error to compare the preference estimation methods and then choose the best way to appreciate model and concluded that hierarchical Poisson regression model that has been appreciated Full Maximum Likelihood Full Maximum Likelihood with sample size (n = 30) is the best to represent the maternal mortality data after it has been reliance value param
... Show MoreThe current research aims to determine the impact of the cognitive reconstruction program on the development of psychological hardness among middle school students through the experimental verification of three hypotheses. The research sample consisted of (16) out of (450) students selected from Ibn Rushud preparatory school- Al-Rusafa 2. These participants have been randomly distributed into two equal groups. The researcher has used the method of cognitive reconstruction with the experimental group, whereas with the controlling group, he used nothing. The researcher has further used the scale of psychological hardness of Kobassa with the participants; the scale has been built in a way that suits the sample of the study, which consisted
... Show MoreAbstract
The aim of this study was to prepare rebamipide ocular inserts in order to extend its release on the ocular surface for dry eye treatment. Solubility study was applied to the drug with or without l-arginine using different solvents. Solvent casting technique was used to prepare the inserts; l-arginine was used to solubilize the drug, hydroxypropyl methylcellulose grades (E5 and K15M) and poly ethylene glycol 200 were used as excipients. The inserts were evaluated for their physical and mechanical properties, moisture loss% and absorption %, surface pH, and in-vitro drug release. The use l-arginine exhibited an enhancement of rebamipide solubility in both deionized water and phosphate buffer (pH 7.4) by a
... Show MoreWe have investigated twenty five patients with type-2 diabetes mellitus aged (35-60) years and fifteen healthy persons as control group to detect Anti-Helicobacter pylori IgG antibody. All studied groups were carried out to measure fasting blood sugar, anti- Glutamic acid decarboxylase (GAD), anti-? islets cells antibody by IFAT, Anti-H. pylori IgG antibody by ELISA technique. There was significant elevation in the concentration of fasting blood sugar than in control group (P < 0.05), the patients had negative results for anti-GAD antibody and anti- ? islets cells antibody, there were significant differences (P < 0.05) of anti-H. pylori IgG antibody in 28 % of patients had type-2 diabetes than control group. This lead to suggestion that typ
... Show MoreThe increasing Global Competitive and the continuous improvement in information technology has led the way to the development of the modern systems and using modern techniques. One of these techniques is benchmarking style and Total Quality Management all of them are used to improve the production process and target rid from the losts on the other side.
The Benchmarking style has become a very important for all the industrial systems and the serving systems as well. And an instrument to improve their performance specially those which are suffering from the highness of the costs or waste in time on the other side.
This study aims to depend on virtual Benchmarking style in the eval
... Show MorePC-based controller is an approach to control systems with Real-Time parameters by controlling selected manipulating variable to accomplish the objectives. Shell and tube heat exchanger have been identified as process models that are inherently nonlinear and hard to control due to unavailability of the exact models’ descriptions. PC and analogue input output card will be used as the controller that controls the heat exchanger hot stream to the desired temperature.
The control methodology by using four speed pump as manipulating variable to control the temperature of the hot stream to cool to the desired temperature.
In this work, the dynamics of cross flow shell and tube heat exchanger is modeled from step changes in cold water f