Preferred Language
Articles
/
6kKXjZoBMeyNPGM3Os3F
Determination of Ferrous Ion in Pure & Pharmaceutical Preparation by Continuous Flow Injection Analysis Via Turbidmetric Utilizing NAG-4SX3-3D Analyzer
...Show More Authors

Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Aerosol And Air Quality Research
Effect of Inner Rod Tilting on the Performance of a Cylindrical Differential Electrical Mobility Analyzer (DEMC)
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Tue Jan 12 2021
Journal Name
Pollution Research
DETERMINATION OF ANILINE IN WASTEWATER BY CLOUDPOINT EXTRACTION FOLLOWED BY HPLC USING 8-HYDROXYQUINOLINE AS A DERIVATIZATION AGENT
...Show More Authors

A procedure, depending on the derivatization and determination of aniline was depicted andvalidated in this study. 8-hydroxyquinoline (8-HQ) was used as the derivatizing agent for thedetermination of aniline. An optimization study was performed for the derivatization reaction, i.e.,the diazonium coupling reaction, the optimum parameters were as follows: 22 mM of hydrochloricacid, 54mM of sodium hydroxide, and 1.8mM of sodium nitrate. The optimization study of themethod of cloud point extraction (CPE) revealed that the extraction solvent was 0.5 ml of Triton X-100, the optimum temperature was 90 °C, and the incubation time was 25 min. The linearity,correlation coefficients, molar absorptivities, and limits of detection were improved using t

... Show More
Publication Date
Tue Jun 30 2009
Journal Name
Al-kindy College Medical Journal
The Effect of Continuous Darkness and Continuous Light on the Reactivity of Smooth Muscles to Drugs in the Rat Vas Deferens
...Show More Authors

Background: The vasoconstricting agents: nor-adrenaline and 5- hydroxytryptamine
(5-HT) have a stimulant action on smooth muscle contractility of the rat vas deferens.
Objective: This study aimed to investigate the effect of exposure to continuous
darkness and continuous light on the contractility of the vasa deferntia smooth
muscles from rats to applied nor-adrenaline and 5-HT.
Method: Male albino wistar rats were divided into 3 experimental groups. Group 1:
Control animals, were exposed to the ordinary photoperiod each day. Group 2: Rats
were kept in a dark room. Group 3: In a room under a bright artificial light.
All animals were killed after 4 weeks.
Results: Vasa deferentia preparations from continuous dar

... Show More
View Publication Preview PDF
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Optimization of Friction Stir Welding Process Parameters to joint 7075-T6 Aluminium Alloy by Utilizing Taguchi Technique
...Show More Authors

In this study, a 3 mm thickness 7075-T6 aluminium alloy sheet was used in the friction stir welding process. Using the design of experiment to reduce the number of experiments and to obtain the optimum friction stir welding parameters by utilizing Taguchi technique based on the ultimate tensile test results. Orthogonal array of L9 (33) was used based on three numbers of the parameters and three levels for each parameter, where shoulder-workpiece interference depth (0.20, 0.25, and 0.3) mm, pin geometry (cylindrical thread flat end, cylindrical thread with 3 flat round end, cylindrical thread round end), and thread pitch (0.8, 1, and 1.2) mm) this technique executed by Minitab 17 software. The results showed th

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Colorimetric Assay of Thiamine Hydrochloride in Pharmaceutical Preparations
...Show More Authors

            A simple, rapid, accurate and sensitive spectrophotometric method for the determination of thiaminehydrochloride has been developed. The method is based on the formation of the Schiff’s base between the primary amino group present in thiamine hydrochloride and aldehyde group present in the vanillin reagent to produce a yellow colored complex having maximum absorption at 390 nm. Beers law has obeaid over the concentration range of 2-28µg/mL, with molar absorptivity of 0.96x104L/mol.cm. The average recovery which is a measure of accuracy is 100±1.3% and the relative standard deviation (RSD) is less than1.5 .The present method is considered to be

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri May 03 2019
Journal Name
Journal Of Physical Education
Effect Special Exercises & Electrical Muscle Stimulation In Maximum Strength Balance by indication Electrical Activity for Muscles on Both Sides of Body For Disabled Weightlifters
...Show More Authors

MJ Abbas, AK Hussein, Journal of Physical Education, 2019

View Publication
Publication Date
Tue Nov 01 2022
Journal Name
Iraqi Journal Of Applied Physics
Highly-Pure Nanostructured Metal Oxide Multilayer Structure Prepared by DC Reactive Magnetron Sputtering Technique
...Show More Authors

In this work, metal oxides nanostructures, mainly, copper oxide (CuO), nickel oxide (NiO), titanium dioxide (TiO2), and multilayer structure were synthesized by dc reactive magnetron sputtering technique. The structural purity and nanoparticle size of the prepared nanostructures were determined. The individual metal oxide samples (CuO, NiO and TiO2) showed high structural purity and minimum particle sizes of 34, 44, 61 nm, respectively. As well, the multilayer structure showed high structural purity as no elements or compounds other than the three oxides were founds in the final sample while the minimum particle size was 18 nm. This reduction in nanoparticle size can be considered as an advantage for the dc reactive magnetron sputtering tec

... Show More
View Publication Preview PDF
Publication Date
Wed Sep 02 2020
Journal Name
Iraqi Journal Of Applied Physics
Heterojunction Solar Cell Based on Highly-Pure Nanopowders Prepared by DC Reactive Magnetron Sputtering
...Show More Authors

In this work, a novel design for the NiO/TiO2 heterojunction solar cells is presented. Highly-pure nanopowders prepared by dc reactive magnetron sputtering technique were used to form the heterojunctions. The electrical characteristics of the proposed design were compared to those of a conventional thin film heterojunction design prepared by the same technique. A higher efficiency of 300% was achieved by the proposed design. This attempt can be considered as the first to fabricate solar cells from highly-pure nanopowders of two different semiconductors.

View Publication Preview PDF
Publication Date
Tue Oct 13 2020
Journal Name
Biochem. Cell. Arch
PREPARATION, CHARACTERIZATION, SPECTROPHOTOMETRIC DETERMINATION OF THE FORMULA OF ACOORDINATION COMPLEX AND BIOLOGICAL STUDIES OF SULFAMETHOXAZOLE (ANTIBIOTIC) WITH TIN DICHLORIDE
...Show More Authors

Sn(II) complex of the type, [Sn(SMZ)2]Cl2 was synthesized by the interaction of Sulfamethoxazole ligand and Tin Chloride, the complex was confirmed on the basis of results of elemental analyses, FT-IR, UV-Vis, molar conductance (Ëm). The elemental analysis data, suggests the stoichiometry to be 1:2 (metal: ligand) and determination of the formula of a coordination a complex formed between the Sn(II) ion and the SMZ using Job’s method of continuous variations. The study of (Ëm), indicated the electrolytic nature type 1:2. The [Sn(SMZ)2]Cl2 was screened for antibacterial activity against Gram-ve (Escherichia coli and Gram+ve (Staphylococcus aureus) and (Candida albicans) antifungal. The IR spectral data suggested that the coordination sit

... Show More
Preview PDF
Publication Date
Fri Jun 05 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of dental implant stability during healing period and determination of the factors that affect implant stability by means of resonance frequency analysis(Clinical study)
...Show More Authors

Background: Implant stability is considered one of the most important factors affecting healing and successful osseointegration of dental implants. The aims of the study were to measure the implant stability quotient (ISQ) values during the healing period and to determine the factors that affect implant stability. Materials and methods: Thirty patients enrolled in the study (17 female, 13 male). They received 44 Implantium® Dental Implants located as the following: 22 implants in maxillary jaw, 22 implants in mandibular jaw from them 17 implants in anterior segment and 27 in posterior segment. The bone density determined using interactive CT scan and classified according to the Misch bone density classification (29 implants in (D3), 15 i

... Show More
View Publication Preview PDF