Flow-injection (FI) spectrophotometric method has been developed for the analysis of thymol in pharmaceutical preparations. The method is based on organic coupling reaction between thymol and 4-amino antipyrine in the presence of alkaline medium to form an intense stable red color complex with copper nitrate that has a maximum absorption at 490 nm. Optimum conditions for determination of the drug was investigated .The calibration graph was linear over the range of 5-500 µg.ml-1 of thymol . The limit of detection (LOD) and limit of quantification (LOQ) were 1.81 ?g mL-1 and 3.60 ?g mL-1 respectively .The proposed method was applied satisfactorily to the determination of thymol in mouth wash preparations. The procedure is characterized by
... Show MoreThis study was aimed to determine bone formation markers (OST and BALP) and lysyl oxidase in diabetes and non-diabetes Iraqi acromegaly patients in addition to find the relationship among these parameters. The present study conducted 60 acromegalic patients (30 diabetes & 30 non diabetes) attending National Diabetes Center / AL-Mustansiriya University/Baghdad, and 30 healthy individuals as a control group aged (35-60) years. All patients were administrated Sandostatin drug, and they were diagnosed by physician in the hospital.FBG, GH, IGF-1, OST, BALP, and LOX were determined in all groups. The results showed a highly significant rise in all parameters (GH, IGF-1, FBG, OST, BALP, and LOX values in serum of all patients when compared with n
... Show MoreAlterations of trace element concentrations adversely affect biological processes and could promote carcinogenesis. Trace element deficiency or excess is implicated in the development or progression of some cancers like colorectal cancer. The aim of the present study was to compare the serum copper (Cu) and zinc (Zn) concentrations in patients with colorectal cancer from Iraqi male patient with those of healthy subjects. During the period of March 2015 until august 2015, a total of 25 patients with metastatic colon cancer and 20 healthy volunteers were enrolled from the Al-Kadhimia Teaching Hospital after the diagnosis using a histopathological examination for the malignant tumor; their age was between (38-60) years. Higher levels o
... Show Moreتصف هذه الدراسة تطوير تقنية سهلة ورخيصة ودقيقة وسريعة لقياس 4-اثيل فينول وتنطوي الطريقة الأولية على تحويل -3 نيترو انيلين إلى ملح ديازونيوم ثم التفاعل مع 4 - إثيل فينول في وسط قلوي.المعقد المتكون هو أصفر اللون وله امتصاص عند اعلى طول موجي عند 426 nm. ويتبع قانون بير في مدى خطي قدره 5-12 μg mL-1 مع معامل ارتباط قدره 0.994 وامتصاص مولاري 6.0024x10^3 L.mol-1.cm-1 وتم استُخدِام تقنية نقطة السحابة لقياس كميات قليلة جدا من الفينول باس
... Show MoreThis work describes the development of new spectrophotometric techniques for 3-aminophenol assessment. The first technique involves using benzidine in an alkaline solution to convert 3-aminophenol into a colored complex. The produced complex has a red color with an absorbance of 462 nm. Between the concentration range 5–14 μg mL−1, Beer's law is obeyed with a correlation coefficient (R2) of 0.99781, a limit of detection (LOD) of 0.0423 μg mL−1, and a limit of quantification (LOQ) of 0.1411 μg mL−1. The recovery was between 87.2–95.43%, the relative standard deviation (%RSD) was 2.40–3.31% and the molar absorptivity was 3.545 × 103 L mol−1 cm−1. Secondly, cloud point extraction (CPE) was used to determ
... Show MoreThe petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa
... Show MoreTo decrease the dependency of producing high octane number gasoline on the catalytic processes in petroleum refineries and to increase the gasoline pool, the effect of adding a suggested formula of composite blending octane number enhancer to motor gasoline composed of a mixture of oxygenated materials (ethanol and ether) and aromatic materials (toluene and xylene) was investigated by design of experiments made by Mini Tab 15 statistical software. The original gasoline before addition of the octane number blending enhancer has a value of (79) research octane number (RON). The design of experiments which study the optimum volumetric percentages of the four variables, ethanol, toluene, and ether and xylene materials leads
... Show MoreThis approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo
... Show MoreAbstract
A sensitive, precise and reliable indirect spectrophotometric method for the determination of chlordiazepoxide (CDE) in pure and pharmaceutical dosage forms is described. The method is based on oxidative coupling reaction between amino group resulting from acidic decomposition of CDE with phenothiazine in the presence of sodium periodate to produce an intense green soluble dye that is stable and shows a maximum absorption at 602 nm. The calibration plot indicates that Beer’s law is obeyed over the concentration range of 0.1?50 µg/mL, with a molar absorptivity of 1×104 L/mol cm and correlation coefficient of 0.9994.All the conditions that affecting on the stability and sensitivity of the fo
... Show More