Preferred Language
Articles
/
6Rj7XpgBVTCNdQwCMLtN
Manufacturing and Testing a Double Action Feed Pellet Durability Measuring Device
...Show More Authors
Abstract<p>The experiment was aimed to evaluate a locally manufactured a dual-action device used for measuring feed pellets durability. The device performs dropping process in conventional devices, then sifting process to separate the pellets from the crumbles simultaneously, with a control the motor speed by using the pulse width modulation (PWM) Technique. The device performance was compared with the durability measuring device of a moving drop box. Rotational speed, diameter of the die holes of the machine was used in this study. The results showed that increasing the rotational speed of the die from 280 to 300 and to 320 rpm, increasing the die holes diameter from 3 to 4 and to 5 mm, led to a significant decrease in the feed pellets durability, for both devices. The lowest die speed of 280 rpm, the minimum diameter of the die holes of 3 mm, recorded the highest pellets durability of 94.45% with the test speed of 33 rpm for the dual action measuring device as well as 93.45% for the movable drop box device. A highly significant correlation was found between data of the both devices. Test device success was proven for measure feed pellets durability.</p>
Scopus Crossref
View Publication
Publication Date
Wed Mar 29 2023
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Testing of a Potentially Used Antiseptic Consists of Povidon Iodine, Hydrogen Peroxide and Aloe Vera
...Show More Authors

In this study a new antiseptic was formulated and tested to match the effectiveness against microorganisms. The formulation consisted of Povidone - Iodine (PVP-I) (10%), H2O2 (3%) and Aloe Vera gel (pure). Different ratios of these materials were prepared within the acceptable range of pH for an antiseptic (3-6). The prepared samples were tested. The In Vitro test was performed by using four bacteria, two were Gram-Positive (Staphylococcus aureus and Bacillus cereus) and two were Gram-Negative (Escherichia coli and Pseudomonas aeruginosa). The new antiseptic showed 100% killing rate for E. coli, Ps. aeruginosa and S. aureus and 96.4667% killing rate for B. cereus. When the new antiseptic was compared with two common

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Computer Systems And Software Engineering
T-Way Testing Strategies
...Show More Authors

In line with the advancement of hardware technology and increasing consumer demands for new functionalities and innovations, software applications grew tremendously in term of size over the last decade. This sudden increase in size has a profound impact as far as testing is concerned. Here, more and more unwanted interactions among software systems components, hardware, and operating system are to be expected, rendering increased possibility of faults. To address this issue, many useful interaction-based testing techniques (termed t-way strategies) have been developed in the literature. As an effort to promote awareness and encourage its usage, this chapter surveys the current state-of-the-art and reviews the state-of-practices in t

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Advances In Systems Analysis, Software Engineering, And High Performance Computing
T-Way Testing Strategies
...Show More Authors

In line with the advancement of hardware technology and increasing consumer demands for new functionalities and innovations, software applications grew tremendously in term of size over the last decade. This sudden increase in size has a profound impact as far as testing is concerned. Here, more and more unwanted interactions among software systems components, hardware, and operating system are to be expected, rendering increased possibility of faults. To address this issue, many useful interaction-based testing techniques (termed t-way strategies) have been developed in the literature. As an effort to promote awareness and encourage its usage, this chapter surveys the current state-of-the-art and reviews the state-of-practices in t

... Show More
View Publication
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Materials Science And Engineering
Gravel Sampling for Testing
...Show More Authors
Abstract<p>Sampling is the selection of a representative portion of a material, and it’s as important as testing. The minimum weight of gravel field or lab sample depends on the nominal maximum particle size. The weight of the sample will always be greater than that portion required for testing. The approximate precision desired for the testing will control the weight of the gravel sample. In this study, gravel sample has been simulated by using multilinear approximated function for Fuller’s curve on the logarithmic scale. Gravel particles are divided into classes according to their medium diameter and each class was simulated separately. A stochastic analysis, by using 100 realizations in s</p> ... Show More
Scopus (1)
Scopus Crossref
Publication Date
Sat May 01 2021
Journal Name
International Journal Of Applied Mechanics And Engineering
Sand Sampling for Testing
...Show More Authors
Abstract<p>Fine aggregate (Sand) is a necessary material used in concrete construction purposes, it’s naturally available and it’s widely used around the world for different parts of construction in any building mainly for filling the voids between gravel. Sand gradation is important for different composite materials, and it gives good cohesion when compared with coarse sand that provides strength for the building. Therefore, sand is necessary to be tested before it is used and mixed with other building materials in construction and the specimen must be selected carefully to represent the real material in the field. The specimen weight must be larger than the required weight for test. When t</p> ... Show More
Scopus Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Scientific Review Engineering And Environmental Studies (srees)
Testing the performance of a solar energy cooling system in Baghdad city
...Show More Authors

Renewable energy resources have become a promissory alternative to overcome the problems related to atmospheric pollution and limited sources of fossil fuel energy. The technologies in the field of renewable energy are used also to improve the ventilation and cooling in buildings by using the solar chimney and heat exchanger. This study addresses the design, construction and testing of a cooling system by using the above two techniques. The aim was to study the effects of weather conditions on the efficiency of this system which was installed in Baghdad for April and May 2020. The common weather in these months is hot in Baghdad. The test room of the design which has a size of 1 m3 was situated to face the geographical south. The te

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Tue Sep 01 2015
Journal Name
Journal Of Biomechanics
In vitro wear testing of a contemporary design of reverse shoulder prosthesis
...Show More Authors

Reverse shoulder arthroplasty is an increasingly common surgical intervention. However there are concerns and known limitations in relation to such joint replacement, while novel designs of reverse shoulder prostheses continue to appear on the market. Many claim to offer improvements over older designs but such assertions are difficult to validate when there is no consensus as to how such implants should be tested in vitro or even if such testing is necessary. In order to permit appropriate in vitro testing of reverse shoulder prostheses a unique, multi-station test rig was designed which was capable of applying motion in three axes to test prostheses. The shoulder simulator can apply up to 110° of motion in the flexion–extension and abd

... Show More
View Publication
Scopus (28)
Crossref (27)
Scopus Clarivate Crossref
Publication Date
Wed Jun 29 2022
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Measuring Dyes Concentration Using a Low-Cost Visible-Light Spectrophotometer
...Show More Authors

   A low-cost, RGB LED-based visible-light spectrophotometer was designed to measure dyes concentration. Dyes are widely used as indicators or coloring agents in different applications and knowing their concentration is an essential part for many studies. The proposed spectrophotometer provides many functionalities that clones the traditional expensive spectrophotometers for a budged price under $50. It was aimed to provide a versatile tool for instructors and educators to teach their students the fundamental concepts behind spectrophotometry. Malachite green, methyl red, and methyl orange dyes were chosen to be good samples to show the integrity of the proposed spectrophotometer in terms of accuracy, repeatability, and sensitivity as

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 18 2023
Journal Name
Cogent Engineering
Investigating the effect of nanomaterials on the Marshall properties and durability of warm mix asphalt
...Show More Authors

This research aims to investigate the effect of four types of nanomaterial on the Marshall properties and durability of warm mix asphalt (WMA). These types are; nano silica(NS), nano carbonate calcium (NCC), nano clay(NC), and nanoplatelets (NP). For each type of Nanomaterial, three contents are tried as following; NS(1%, 3%, and 5%), NCC(2%, 4%, and 6%), NC(3%, 5%, and 7%), and NP (2%, 4%, and 6%) by weight of asphalt cement. Following Marhsall mix design method, the optimum asphalt cement content is determined, thereafter the optimum dosage for each nanomaterial is obtained based on the highest Marshall stability value. The durability of the control mix (no nanomaterial) and modified mixtures have been compared based on moisture damage, r

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Lab on-a-chip-based, an integrated microfluidic device lo-cost, rapid, and sensitive analysis of Augmentin
...Show More Authors

Microfluidic devices provide distinct benefits for developing effective drug assays and screening. The microfluidic platforms may provide a faster and less expensive alternative. Fluids are contained in devices with considerable micrometer-scale dimensions. Owing to this tight restriction, drug assay quantities are minute (milliliters to femtoliters). In this research, a microfluidic chip consisting of micro-channels carved on substrate materials built using an Acrylic (Polymethyl Methacrylate, PMMA) chip was designed using a Carbon Dioxide (CO2) laser machine. The CO2 parameters influence the chip’s width, depth, and roughness. To have a regular channel surface, and low roughness, the laser power (60 W), with scanning speed (250 m/s)

... Show More
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref