Hyperthyroidism or thyrotoxicosis occurs due to excess release of thyroid hormone. These hormones regulate the body’s energy balance and have effects on adipokine level. There are several reports suggesting interrelation between adipokines (resistin and leptin) with thyroid dysfunction. Objectives: This study was established to investigate the effect of thyroid hormones in hyperthyroidism state on the level of some adipokines, leptin and resistin; in comparison with control. Patients and Methods: The present study included 50 Iraqi female patients with hyperthyroidism with age ranged between 30-58 years and 30 healthy controls with age ranged between 30-53 years. Serum samples were collected from study groups. The levels of thyroid hormones (TSH, T4 and T3) were determined by using automated Chemiluminescence Immunoassay (CLIA) analysis system. Detection of leptin hormone and resistin hormone levels in the serum were determined by an enzyme linked immunosorbent assay (ELISA) kits. Results: The results revealed that serum leptin levels were significantly low (P<0.004) in hyperthyroid patient groups as compared to control, and there were significant negative correlations between T4 and leptin (P<0.0001); also, T3 and leptin (P<0.05). Resistin hormone level increased non-significantly (P˃0.05) than control level; and there was significant negative correlation between TSH and resistin (P<0.035). Conclusion: The study shows that there is complex interrelation between adipocytokines (leptin and resistin) with thyroid gland and pituitary gland. Leptin levels were decreased in hyperthyroid patients than control and associated negatively with T4 and T3 levels, while resistin levels were increased non-significantly than control and associated negatively with TSH level. They affect each other in their physiological function in the human body.
Nuclear emission rates for nucleon-induced reactions are theoretically calculated based on the one-component exciton model that uses state density with non-Equidistance Spacing Model (non-ESM). Fair comparison is made from different state density values that assumed various degrees of approximation formulae, beside the zeroth-order formula corresponding to the ESM. Calculations were made for 96Mo nucleus subjected to (N,N) reaction at Emax=50 MeV. The results showed that the non-ESM treatment for the state density will significantly improve the emission rates calculated for various exciton configurations. Three terms might suffice a proper calculation, but the results kept changing even for ten terms. However, five terms is found to give
... Show MoreIn this study, the effect of fire flame on the punching shear strength of steel fiber reinforced concrete flat plates was experimentally investigated using nine half-scale specimens with dimensions of 1500×1500 mm and a total thickness of 100 mm. The main investigated variables comprised the steel fiber volume fraction 0, 1, and 1.5% and the burning steady state temperature 500 and 600 °C. The specimens were divided into three groups, each group consists of three specimens. The specimens in the first group were tested with no fire effect to be the reference specimens, while the others of the second and third groups were tested after being exposed to fire-flame effect. The adopted characteristics of the fire test were; (one hour) b
... Show MoreIn this work, silicon nitride (Si3N4) thin films were deposited on metallic substrates (aluminium and titanium sheets) by the DC reactive sputtering technique using two different silicon targets (n-type and p-type Si wafers) as well as two Ar:N2 gas mixing ratios (50:50 and 70:30). The electrical conductivity of the metallic (aluminium and titanium) substrates was measured before and after the deposition of silicon nitride thin films on both surfaces of the substrates. The results obtained from this work showed that the deposited films, in general, reduced the electrical conductivity of the substrates, and the thin films prepared from n-type silicon targets using a 50:50 mixing ratio and deposited on both
... Show MoreThe taxonomy of Ficus L., 1753 species is confusing because of the intense morphological variability and the ambiguity of the taxa. This study handled 36 macro-morphological characteristics to clarify the taxonomic identity of the taxa. The study revealed that Ficus is represented in the Egyptian gardens with forty-one taxa; 33 species, 4 subspecies and 4 varieties, and classified into five subgenera: Ficus Corner, 1960; Terega Raf., 1838; Sycomorus Raf., 1838; Synoecia (Miq.) Miq., 1867, and Spherosuke Raf.,1838; out of them seven were misidentified. Amongst, four new Ficus taxa were recently introduced to Egypt namely: F. lingua subsp. lingua Warb. ex De Wild. & T. Durand, 1901; F. pumila L., 1753; F. rumphii Blume, 1825, and F. su
... Show MoreAbstract :H.pylori is an important cause of gastric duodenal disease, including gastric ulcers, Mucosa-associated lymphoid tissue (MALT), and gastric carcinoma. biosensors are becoming the most extensively studied discipline because the easy, rapid, low-cost, highly sensitive, and highly selective biosensors contribute to advances in next-generation medicines such as individualized medicine and ultrasensitive point-of-care detection of markers for diseases. Five of ten patients diagnosed with H.pylori ranging in age from 15–85 participated in this research. who [gastritis, duodenitis, duodenal ulcer (DU), and peptic ulcer (PU)] Suspected H.pylori colonies w
... Show MoreAmong a collection of leafhoppers from Erbil Province in Kurdistan/Iraq, a new species of the genus Arboridia Zakhvatkin, 1946 was designated and described here as a new species to the science. The erection of this species was mainly built on the external characters included the male genitalia. Sites and dates of collections so as the host-plants were verified.
Fiber Reinforced Polymer (FRP) bars are anisotropic in nature and have high tensile strength in the fiber direction. The use of High-Strength Concrete (HSC) allows for better use of the high-strength properties of FRP bars. The mechanical properties of FRP bars can yield to large crack widths and deflections. As a result, the design of concrete elements reinforced with FRP materials is often governed by the Serviceability Limit States (SLS). This study investigates the short-term serviceability behavior of FRP RC I-beams. Eight RC I-beams reinforced with carbon-FRP (CFRP) and four steel RC I-beams, for comparison purposes, were tested under two-point loading.
Deformations on the concrete and crack widths and spacing are measured and