Preferred Language
Articles
/
5hfBbo8BVTCNdQwCv3c_
Evaluation of the Antibacterial Efficacy of Electrolyzed Oxidizing Water as an Irrigant against Enterococcus faecalis (An In vitro Study)
...Show More Authors

Evaluation of the Antibacterial Efficacy of Electrolyzed Oxidizing Water as an Irrigant against Enterococcus faecalis (An In vitro Study), Noor A Khait*, Muna Saleem Kalaf

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Oct 11 2021
Journal Name
Nano Hybrids And Composites
Far Infrared Laser Detector Based on Multi-Walled Carbon Nanotubes and Blend of (Polyaniline - Polymethyl Methacrylate) Polymers with Methyl Blue Dye for Photoconductive Applications
...Show More Authors

Infrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector

... Show More
View Publication
Crossref (1)
Clarivate Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Manganese Ions (Mn2+) from a Simulated Wastewater by Electrocoagulation/ Electroflotation Technologies with Stainless Steel Mesh Electrodes: Process Optimization Based on Taguchi Approach
...Show More Authors

This study depicts the removal of Manganese ions (Mn2+) from simulated wastewater by combined electrocoagulation/ electroflotation technologies. The effects of initial Mn concentration, current density (C.D.), electrolysis time, and different mesh numbers of stainless steel screen electrodes were investigated in a batch cell by adopting Taguchi experimental design to explore the optimum conditions for maximum removal efficiency of Mn. The results of multiple regression and signal to noise ratio (S/N) showed that the optimum conditions were Mn initial concentration of 100 ppm, C.D. of 4 mA/cm2, time of 120 min, and mesh no. of 30 (wire/inch). Also, the relative significance of each factor was attained by the analysis

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of The College Of Languages (jcl)
ARZI KANBER HİKAYESİ'NİN IRAK TÜRKMENLERİ ARASINDA TESPİT EDİLEN YENİ BİR VARYANTI'NIN İNCELENMESİ ANALYZING A NEW TEXT OF " ARZO AND QENBER "TALE AMONG IRAQI TURKMENS
...Show More Authors

Öz      

            Arzı Kanber/Kamber hikayesi Anadolu, Rumeli, Azerbaycan, Türkmenistan ve Irak gibi Türk dünyasının birçok yerinde birden fazla varyantı bulunan, çok sevilen ve yaygın olarak anlatılan aşk ve dramatik maceralı bir halk hikayesidir. Türk halk hikayelerinin en popüler olanlarından biri sayılan Arzı Kanber/Kamber hikayesi, Anadolu'nun birçok yöresinde bilinmesine rağmen Irak Türkmenleri arasında daha çok sevildiği ve yaygın olarak anlatıldığı tespit edilen birden fazla varyantından da görülebilir. Irak Türkmenleri arasında günümüze kadar hikayenin iki varyantı tespit edilmi

... Show More
View Publication Preview PDF
Publication Date
Sat Nov 22 2014
Journal Name
Indian Journal Of Physics
Comparison between shell model and self-consistent mean field calculations for ground charge density distributions and elastic form factors of 12C and 16O nuclei
...Show More Authors

View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed May 07 2008
Journal Name
Journal Of Kerbala University
Synthesis and Characterization of New Ligand type N2O2 and its complexes with (Co(II),Ni(II),Cu(II),Zn(II) and Cd(II) ions
...Show More Authors

The [2-hydroxy -1,2-diphynel-ethanone oxime] was reacted with 1,2- dichloroethan to give the new ligand [H2L].this ligand was reacted with some metal ions (Co(II),Ni(II),Cu(II),Zn(II) and Cd(II) in methanol as a solvent to give a series of new (1:1)complexes of the general formula [ M(HL)]Cl ,( where : M= Co(II),Ni(II),Cu(II),Zn(II) and Cd(II)) are isolated All compounds have been characterized by spectroscopic methods [ I.R , U.V -Vis ] atomic absorption . Chloride content along with conductivity measurements. From the above data the proposed molecular structure for (Co, Cu, Ni, Zn and Cd) complexes adopting a tetrahedral structure.

Publication Date
Wed Mar 05 2025
Journal Name
Water, Air, & Soil Pollution
Adsorptive Performance of High Surface Area Date Palm Bunch Activated Carbon Towards Methyl Violet and Fuchsin Basic Dyes Removal: Thermochemical Activation And Statistical Optimization
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon May 01 2023
Journal Name
Environmental Nanotechnology, Monitoring & Management
Photodegradation of tetracycline antibiotic by ternary recyclable Z-scheme g-C3N4/Fe3O4/Bi2WO6/Bi2S3 photocatalyst with improved charge separation efficiency: Characterization and mechanism studies
...Show More Authors

View Publication
Scopus (36)
Crossref (10)
Scopus Crossref
Publication Date
Sat Sep 01 2012
Journal Name
Australian Journal Of Basic And Applied Sciences
Electrochemical interferences of Mn<sup>2+</sup> with Hg<sup>2+</sup>, Cd<sup>2+</sup> and Cu<sup>2+</sup> at different modified GCE
...Show More Authors

Glassy carbon electrode (GCE) was modified with carbon nanotubes CNT and C60 by attachment and solution evaporation techniques, respectively. CNT/Li+/GCE and C60/Li+/GCE were prepared by modifying CNT/GCE and C60/GCE in Li+ solution via cyclic voltammetry (CV) potential cycling. The sensing characteristics of the modified film electrodes, demonstrated in this study for interference of Mn2+ in different heavy metals ion esp. Hg2+, Cd2+ and Cu2+. The interfering effect was investigated that exert positive interference on the redox peaks of Mn2+. The modification of GCE with nano materials and Li+ act an enhancement for the redox current peaks to observe the effect of interference for Mn2+ in 1:1 ratio with different heavy metals ion.

Scopus (3)
Scopus
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
sw uobaghdad edu iqSynthesis and Characterization of Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Hg(II) Complexes with Symmetrical Schiff base
...Show More Authors

New binuclear Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Hg(II) Complexes of N2S2 tetradentate or N4S2 hexadentate symmetric Schiff base were prepared by the condensation of butane-1,4-diylbis(2-amino ethylcarbamodithioate) with 3-acetyl pyridine. The complexes having the general formula [M2LCl4] (where L=butane-1,4-diyl bis (2-(z)-1-(pyridine-3-ylethylidene amino))ethyl carbamodithioate, M= Mn(II), Co(II), Ni(II), Cu(II), Zn(II), and Hg(II)), were prepared by the reaction of the mentioned metal salts and the ligand. The resulting binuclear complexes were characterized by molar conductance, magnetic susceptibility ,infrared and electronic spectral measurements. This study indicated that Mn(II), Ni(II) and Cu(II) complexes have octahedral g

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Oct 01 2019
Journal Name
International Journal Of Drug Delivery Technology
Simple and Rapid Method For Estimate of Propranolol With Bi (III) Via Long-Distance Chasing Photometer (NAG-ADF-300-2) Utilization Continuous Flow Injection Analysis
...Show More Authors

A simple, sensitive and rapid method was used for the estimate of: Propranolol with Bi (III) to prove the efficiency, reliability and repeatability of the long distance chasing photometer (NAG-ADF-300-2) using continuous flow injection analysis. The method is based on a reaction between propranolol and Bi (III) in an aqueous medium to obtain a yellow precipitate. Optimum parameters were studied to increase the sensitivity for the developed method. A linear range for calibration graph was 0.1-25 mmol/L for cell A and 1-40 mmol/L for cell B, and LOD 51.8698 ng/200 µL and 363.0886 ng /200 µL , respectively to cell A and cell B with correlation coefficient (r) 0.9975 for cell A, 0.9966 for cell B, RSD% was lower than 1%, (n = 8) for the

... Show More