Background: Plasma-activated water (PAW) is considered one of the emerging strategies that has been highlighted recently in the food industry for microbial decontamination and mycotoxin detoxification, due to its unique provisional characteristics. Aim: The effectiveness of PAW for aflatoxin B1 (AFB1), ochratoxin A (OTA), and fumonisin B1 (FB1) detoxification in naturally contaminated poultry feeds with its impacts on the feed quality were inspected. Methods: PAW-30 and PAW-60 were utilized for feed treatment for six time durations (5, 10, 15, 20, 40 and 60 min) each. The alterations in the physicochemical properties of PAW after different time durations of plasma inducement and treatment with and without feed samples were monitored. Competitive Enzyme-Linked Immunosorbent Assay (ELISA) was employed for estimation of mycotoxin levels and High Performance Liquid Chromatography (HPLC) was utilized for results confirmation. Feed composition analyses with peroxide values (PVs) estimation were implemented according to standard analytical methods. Results: The physicochemical properties of PAW showed a significant decrease (P<0.05) in pH value from 6.72 to 2.68 and a significant increase (P<0.05) in oxidation-reduction potential (ORP), electrical conductivity (EC) and temperature from 235 mV, 5.1 μS/cm and 20.5 °C to 499.2 mV, 727.6 μS/cm and 26.8 °C, respectively after 60 min of plasma inducement in a time-dependent manner. The mycotoxins decay kinetics after PAW application were illustrated. Mycotoxins degradation efficiency significantly increased (P<0.05) with increasing water activation time. A significant increase (P<0.05) in AFB1, OTA and FB1 degradation levels was reported mainly during the first 10 min of treatment for AFB1 and the first 15 min for OTA and FB1 to record values of 28.33, 32.14 and 34.62% and 33.80, 40.70 and 43.38% after 60 min of feed exposure to PAW-30 and PAW-60, respectively. Significant differences (P<0.05) between examined mycotoxins in their degradation levels were recorded, where FB1 exhibited the highest degradation levels. Generally, feed compositions were slightly affected by PAW and fats were still having good quality. Conclusion: The possibility of PAW for degrading more than a quarter to a third of the original quantity of targeted mycotoxins in poultry feeds after 10 min of treatment with a slight effect on feed quality.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Jan 31 2017
Journal Name
Journal Of Engineering
The Effect of The Utilitarian Need For the High Water Tanks Towers to Sustain Life in the City
...Show More Authors

      The service system has become a necessity of life in modern cities to be the most basic necessities of modern humans, they constitute a major base, which is based on the sustainability of life in the city and a standard measured through the degree of well-being and progress of civilized peoples and their interaction with the surrounding environment, making the services sector as a need not be an option, whenever the cities widened in population and space whenever provision of services and upgrading the quality and quantity more pressing, which made the subject of the services takes the biggest area of the trends and thinking of urban planners and those who in charge of drawing the cities policies. Consideri

... Show More
View Publication Preview PDF
Publication Date
Sat Aug 01 2020
Journal Name
Journal Of Engineering
Experimental Evaluation of Evaporative Cooling for Enhancing Photovoltaic Panels Efficiency Using Underground Water
...Show More Authors

This paper presents an experimental study of cooling photovoltaic (PV) panels using evaporative cooling. Underground (geothermal energy) water used to extract heat from it during cooling and cleaning of PV panels. An experimental test rig was constructed and tested under hot and dusty climate conditions in Baghdad. An active cooling system was used with auxiliary an underground water tank to provide cold water as a coolant over both PV surfaces to reduce its temperature. The cellulose pad has been arranged on the back surface and sprays cooling on the front side. Two identical PV panels modules used: without cooling and evaporative water cooling. The experiments are comprised of four cases: Case (I): backside cooling, Ca

... Show More
View Publication Preview PDF
Crossref (13)
Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Global Pharma Technology
Application of H-Point Standard Addition Method in Kinetic- Spectrophotometric Determination of Phenylephrine in Nasal Drops and Tetracycline in Capsule
...Show More Authors

A new simultaneous spectrophotometric-kinetic method was developed to determine phenylephrine (PHEN) and tetracycline (TETR) via H-point standard addition method (HPSAM). The proposed procedures rely on the measurements of the difference in the rate of charge-transfer (CT) reaction between each of PHEN and TETR as electron donors with p-Bromanil (p-Br) as an electron acceptor. Different experimental factors which affect the extent of the complex formation were investigated by monitoring the value of absorbance at 446 nm. Time pair of 50 -100 sec was selected and employed, among different examined pairs since it results in the highest accuracy for HPSAM-plot. Linear calibration graphs in the concentration ranges of 10.0-40.0 and 10.0–50.0

... Show More
Publication Date
Thu Sep 01 2022
Journal Name
Https://www.researchgate.net/journal/university-of-baghdad-engineering-journal-1726-4073
Hazard analysis in drinking water plant
...Show More Authors

Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators

Crossref
Publication Date
Thu Sep 01 2022
Journal Name
Journal Of Engineering
Hazard analysis in drinking water plant
...Show More Authors

Source, sedimentation, coagulation, flocculation, filter, and tank are parts of a water treatment plant. As a result, some issues threaten the process and affect the drinking water quality, which is required to provide clean drinking water according to special standards and international and local specifications, determined by laboratory results from physical, chemical, and biological tests. In order to keep the water safe for drinking, it is necessary to analyze the risks and assess the pollution that occurs in every part of the plant. The method is carried out in a common way, which is monitoring through laboratory tests, and it is among the standards of the global and local health regulators

View Publication Preview PDF
Crossref
Publication Date
Thu Feb 11 2016
Journal Name
Journal Of Materials Science: Materials In Electronics
Electrochemical deposition of CdSe-sensitized TiO2 nanotube arrays with enhanced photoelectrochemical performance for solar cell application
...Show More Authors

View Publication
Scopus (23)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Comparison between Linear and Non-linear ANN Models for Predicting Water Quality Parameters at Tigris River
...Show More Authors

In this research, Artificial Neural Networks (ANNs) technique was applied in an attempt to predict the water levels and some of the water quality parameters at Tigris River in Wasit Government for five different sites. These predictions are useful in the planning, management, evaluation of the water resources in the area. Spatial data along a river system or area at different locations in a catchment area usually have missing measurements, hence an accurate prediction. model to fill these missing values is essential.
The selected sites for water quality data prediction were Sewera, Numania , Kut u/s, Kut d/s, Garaf observation sites. In these five sites models were built for prediction of the water level and water quality parameters.

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Soil Science Society Of America Journal
Agroforestry, grass, biofuel crop, and row‐crop management effects on soil water dynamics for claypan landscapes
...Show More Authors

Soil water use and water storage vary by vegetative management practices, and these practices affect land productivity and hydrologic processes. This study investigated the effects of agroforestry buffers (AB), grass buffers (GB), and biofuel crops (BC), relative to row crops (RC) on soil water use for a claypan soil in northern Missouri, USA. The experiment located at the Greenley Memorial Research Center included RC, AB, GB, and BC established in 1991, 1997, 1997, and 2012, respectively. Soil water reflectometer sensors installed at 5‐, 10‐, 20‐, and 40‐cm depths monitored soil water from April to November in 2017 and 2018. Results showed significant differences in weekly volumetric water content (VWC) among treatments for all fou

... Show More
View Publication
Scopus (10)
Crossref (10)
Scopus Clarivate Crossref
Publication Date
Fri Nov 01 2019
Journal Name
Journal Of Engineering
Demulsification of Water in Iraqi Crude Oil Emulsion
...Show More Authors

Formation of emulsions during oil production is a costly problem, and decreased water content in emulsions leads to increases productivity and reduces the potential for pipeline corrosion and equipment used. The chemical demulsification process of crude oil emulsions is one of the methods used for reducing water content. The demulsifier presence causes the film layer between water droplets and the crude oil emulsion that to become unstable, leading to the accelerated of water coalescence. This research was performed to study the performance of a chemical demulsifier Chimec2439 (commercial) a blend of non-ionic oil-soluble surfactants. The crude oils used in these experiments were Basrah and Kirkuk Iraqi crude oil. These

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Tue Feb 05 2019
Journal Name
Journal Of The College Of Education For Women
The study of physical and chemical properties of wells water in district of Samarra
...Show More Authors

The Study was achieved adjectives physical and chemical water wells in the district of
Samarra , where a study has 42 sample groundwater in different regions of the judiciary
randomly distributed all over the judiciary and examined in vitro.
The study showed that the quality of groundwater in the general area of study
Kipritateh punctuated Klordih water quality and other quality Bicarboonatih.
Varied the key components of groundwater in the study area in concentrations
between periods of rain and drought, especially because of the cation ion exchange processes
as well as mitigation as a result of filtering rain water and dominated the calcium ion,
followed by sodium.
As for the negative ions has dominated ion s

... Show More
View Publication Preview PDF