Background: Plasma-activated water (PAW) is considered one of the emerging strategies that has been highlighted recently in the food industry for microbial decontamination and mycotoxin detoxification, due to its unique provisional characteristics. Aim: The effectiveness of PAW for aflatoxin B1 (AFB1), ochratoxin A (OTA), and fumonisin B1 (FB1) detoxification in naturally contaminated poultry feeds with its impacts on the feed quality were inspected. Methods: PAW-30 and PAW-60 were utilized for feed treatment for six time durations (5, 10, 15, 20, 40 and 60 min) each. The alterations in the physicochemical properties of PAW after different time durations of plasma inducement and treatment with and without feed samples were monitored. Competitive Enzyme-Linked Immunosorbent Assay (ELISA) was employed for estimation of mycotoxin levels and High Performance Liquid Chromatography (HPLC) was utilized for results confirmation. Feed composition analyses with peroxide values (PVs) estimation were implemented according to standard analytical methods. Results: The physicochemical properties of PAW showed a significant decrease (P<0.05) in pH value from 6.72 to 2.68 and a significant increase (P<0.05) in oxidation-reduction potential (ORP), electrical conductivity (EC) and temperature from 235 mV, 5.1 μS/cm and 20.5 °C to 499.2 mV, 727.6 μS/cm and 26.8 °C, respectively after 60 min of plasma inducement in a time-dependent manner. The mycotoxins decay kinetics after PAW application were illustrated. Mycotoxins degradation efficiency significantly increased (P<0.05) with increasing water activation time. A significant increase (P<0.05) in AFB1, OTA and FB1 degradation levels was reported mainly during the first 10 min of treatment for AFB1 and the first 15 min for OTA and FB1 to record values of 28.33, 32.14 and 34.62% and 33.80, 40.70 and 43.38% after 60 min of feed exposure to PAW-30 and PAW-60, respectively. Significant differences (P<0.05) between examined mycotoxins in their degradation levels were recorded, where FB1 exhibited the highest degradation levels. Generally, feed compositions were slightly affected by PAW and fats were still having good quality. Conclusion: The possibility of PAW for degrading more than a quarter to a third of the original quantity of targeted mycotoxins in poultry feeds after 10 min of treatment with a slight effect on feed quality.
The corrosion behavior of low carbon steel in washing water of crude oil solution has been studied potentiostatically at five temperatures in the range ( 303 –343 )K, at pH ( 4 ) and at pH (4,6,7,9,11 ) at (343K)..The corrosion potential shifted to more negative values with increasing temperature and the corrosion current density increased with increasing temperature, the corrosion current density (icorr) decreased with increasing pH in the rang ( 4 – 7 ) and it increased with increasing pH in the rang ( 9 – 11 ) at ( 343 K ), while the corrosion potential generally variation with increasing pH in the rang (4-11)at(343K. From the general results for this study can be seen that thermodynamic and kinetic function were
... Show MoreThe red tripyrrole pigment known as prodigiosin (PG), which belongs to the prodigiosin family, is an interesting substance that has attracted the attention of scientists due to its versatility. Thanks to its striking red pigment and distinctive chemical characteristics, prodigiosin has caught the attention of researchers seeking new solutions across a variety of disciplines. Serratia marcescens and other bacteria like Hahella chejuensis, Vibrio gazogenes, Pseudoalteromonas rubra, Janthinobacterium lividum, Actinomadura madurae, and Streptomyces coelicolor produce prodigiosin, a red pigment that functions as secondary metabolite. Prodigiosin has shown promising activity as an antibacterial agent in numerous experiments. Prodigiosin is a prom
... Show MoreIn this research, the water quality of the potable water network in
Al-Shuala Baghdad city were evaluated and compare them with the
Iraqi standards (IQS) for drinking water and World Health
Organization standards (WHO), then water quality index (WQI) were
calculator: pH, heavy metals (lead, cadmium and iron), chlorides,
total hardness, turbidity, dissolved oxygen, total dissolved solid and
electrical conductivity. Water samples are collected weekly during
the period from February 2015 to April 2015 from ten sites. Results
show that the chlorides, total dissolved solid and electrical
conductivity less than acceptable limit of standards, but total
hardness and heavy metals in some samples higher than acceptabl
The manuscript should contain an abstract. The abstract should be self-contained and citation-free and should not exceed 200 words. The abstract should state the purpose, approach, results and conclusions of the work. The author should assume that the reader has some knowledge of the subject but has not read the paper. Thus, the abstract should be intelligible and complete in it-self (no numerical references); it should not cite figures, tables, or sections of the paper. The abstract should be written using third person instead of first perso The fast microwave assisted pyrolysis (FMWAP) of water hyacinth (WH) for biochar production is investigated. Taguchi’s method was used to optimize FMWAP parameters. The effects of microwave
... Show MoreIn the present study, activated carbon supported metal oxides was prepared for thiophene removal from model fuel (Thiophene in n-hexane) using adsorptive desulfurization technique. Commercial activated carbon was loaded individually with copper oxide in the form of Cu2O/AC. A comparison of the kinetic and isotherm models of the sorption of thiophene from model fuel was made at different operating conditions including adsorbent dose, initial thiophene concentration and contact time. Various adsorption rate constants and isotherm parameters were calculated. Results indicated that the desulfurization was enhanced when copper was loaded onto activated carbon surface. The highest desulfurization percent for Cu2O/AC and o
... Show MoreThis study is to evaluate plasma levels of several cytokines in preeclamptic pregnancies compared to those of healthy pregnancies. Ninety pregnant women with preeclampsia (37 mild & 53 severe) and thirty healthy pregnant women were enrolled in the study. Blood samples were taken and plasma levels of IL-8, IL-10, and IFN-? were measured by enzyme-linked immunosorbent assay (ELISA). Preeclamptic women and their severe cases but not mild cases had significantly (P<0.05) increased levels of plasma IL-8, and IFN-? as compared with healthy pregnancies. By contrast, plasma levels of IL-10 was significantly (P<0.05) increased in healthy pregnant women as compared to all groups of preeclampsia. Preeclampsia is associated with an imbalance betwe
... Show MoreThe calculation of the charge on an isolated dust grain immersed in plasma with different grain sizes is a challenging one, especially under moderately high plasma temperature when secondary electron emission significant. The discrete charging model is used to calculate the charges of dust grain in dusty plasma. In this model, we included the effect of grain size dependence on secondary electron emission. The results show that the secondary electron emission from the glass dust grains due to energetic electron (40eV) can lead to the small grain to be slightly more positive than the large grain. Under these conditions, the smaller and larger grains would be attracted rather than repelled, which possibly lead to enhanced coagulation rates.
... Show MoreThe main goal of this work is to obtain the plasma electron temperature Te by optical emission spectroscopy of low pressure microwave argon plasma, as a function of working pressure and microwave power. A plasma system was designed and constructed in our laboratory using a magnetron of domestic microwave oven with power 800W without any commercial part. The applied voltage on the magnetron electrical circuit is changed for the purpose of obtaining the variable values of the microwave power. The spectral detection is performed with a spectrometer of wavelength range (200−1000nm). The working pressure and magnetron applied voltage were 0.3-3.0mbar and 180-240V, respectively. Two methods had been applied to estimate the electron temperatu
... Show MoreENGLISH