The investigation of earth dams under significant earthquake loads, such as catastrophic earthquakes, is a critical subject in dynamic evaluation. Damage mitigation and structural performance during an earthquake are crucial considerations for an earthen dam. However, Iraq and its neighbors have experienced frequent earthquake activity, including the 2017 Halabja Earthquake, which may have damaged some existing earth dams, posing a higher risk of severe earthquake-induced damage than a cyclic shock. Therefore, assessing the dam’s safety is crucial for protecting downstream communities and determining the best strategies to prevent slope stability failure in the face of frequent s
In this work, studying the effect of ethylenediamine as a corrosion inhibitor was investigated for carbon steel in aerated HCl solution in range of 0.1-1N under dynamic conditions, i.e., rotational velocity of 400–1200 rpm in the temperature range 35 – 65 ºC. Weight loss method was employed in absence and presence of the inhibitor as an adsorption type in concentration range 1000 – 5000 ppm using rotating cylinder specimens. The experimental results showed that corrosion rate in absence and presence of inhibitor is increased with increasing temperature, rotational velocity and concentration of acid. It is decreased with increasing inhibitor concentration for the whole range of temperature, rotational velocity and concentrati
... Show MoreThis study focuses on the modeling of manufactured damper when used in steel buildings. The main aim of the manufactured dampers is to protect the steel buildings from the damaging effects that may result due to earthquakes by introducing an extra damping in addition to the traditional damping.
Only Pure Manufactured Dampers, has been considered in this study. Viscous modeling of damping is generally preferred in structural engineering as it leads to a linear model then it has been used during this study to simulate the behavior of the Pure Manufactured Damper.
After definition of structural parameters of a manufactured damper (its stiffness and its damping) it can be used as a structural element that can be added to a mathematica
In the geotechnical engineering applications, precise understandings are yet to be established on the effects of a foundation stiffness on its bearing capacity and settlement. The modern foundation construction uses the new available construction materials that totally change the relative stiffness of the footing structures-soil interactions such as waste material and landfill area of more residential purposes. Conventional bearing capacity equations were dealt with common rigid footing and thus cannot be used for reduced foundation rigidity. Therefore, this study investigates the effects of foundation relative stiffness on its load-displacement behaviour and the soil deformation field using compression test of a strip smooth footings on su
... Show MoreThis study investigates the influence of fear, refuge, and migration in a predator–prey model, where the interactions between the species follow an asymmetric function response. In contrast to some other findings, we propose that prey develop an anti-predator response in response to a concentration of predators, which in turn increases the fear factor of the predators. The conditions under which all ecologically meaningful equilibrium points exist are discussed in detail. The local and global dynamics of the model are determined at all equilibrium points. The model admits several interesting results by changing the rate of fear of predators and predator aggregate sensitivity. Numerical simulations have been performed to verify our theoret
... Show MoreThe evacuated tube solar collector ETC is studied intensively and extensively by experimental and
theoretical works, in order to investigate its performance and enhancement of heat transfer, for Baghdad climate
from April 2011 till the end of March 2012. Experimental work is carried out on a well instrumented collector
consists of 16 evacuated tubes of aspect ratio 38.6 and thermally insulated tank of volume 112L. The relation
between convective heat transfer and natural circulation inside the tube is estimated, collector efficiency, effect of
tube tilt angles, incidence angle modifier, The solar heating system is investigated under different loads pattern (i.e
closed and open flow) to evaluate the heat loss coefficient