Preferred Language
Articles
/
5ReQOI8BVTCNdQwCymOc
Impacts of porous medium on unsteady helical flows of generalized oldroyd-B fluid with two infinite coaxial circular cylinders
...Show More Authors

Scopus
Publication Date
Mon Aug 31 2020
Journal Name
Journal Of Research In Medical And Dental Science
The Effect of Super Oxidized Water Mouthwash on the Level of IL 1? in Gingival Crevicular Fluid for Patients with Gingivitis Randomized Clinical Trial
...Show More Authors

Background: One of the most predominant periodontal diseases is the plaque induced gingivitis. For the past 20 years, super-oxidized solutions have be..

View Publication Preview PDF
Publication Date
Sun Dec 01 2019
Journal Name
2019 Ieee Asia-pacific Conference On Computer Science And Data Engineering (csde)
Effect of Lime, Cement, and Lime-Cement Stabilisation on Low to Medium Plasticity Clayey Soil
...Show More Authors

View Publication
Scopus (9)
Crossref (7)
Scopus Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Enhancement of Atorvastatin Tablet Dissolution Using Acid Medium
...Show More Authors

         In this study some generic commercial products of Atorvastatin tablets were evaluated by dissolution test in acid medium by comparing with that of parent drug Lipitor of Pfizer Company. Some of solubilizing agents were studied in formulation  of Atorvastatin tablet including;  surface active agent  and PEG 6000 .The most effective factor was the  use of PEG6000 in formulation of Atorvastatin tablet which improved the dissolution and the results of dissolution profile of formulated tablet in this work  was bioequivalent to that of Lipitor .The quantitative analysis of this work was performed by using reversed phase liquid chromatography and a proper mixture of &nbsp

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Exfoliative Cytological Changes in Peritoneal Fluid from Patients on Peritoneal Dialysis
...Show More Authors

Background: Ambulatory peritoneal dialysis
introduced by Popvich et al (13) in 1978 , consists of a
four to five hours lavage of peritoneal cavity with 2000
ml of glucose solution .It remains a useful method for
treating patients with end stage renal failure till renal
transplantation becomes possible.
Objectives: The aim of the study is to evaluate the
value of cytological changes of mesothelial cells in
dialysate patients.
Methods: Within one year period, 32 cytological
peritoneal fluid samples were collected from patients
with end stage renal failure regardless of the underlying
causes, admitted to the dialyzing unit in Kadimya
Teaching Hospital. Smears were prepared and fixed in
95 % ethyl al

... Show More
View Publication Preview PDF
Publication Date
Sun Nov 01 2015
Journal Name
Journal Of Engineering
Heat Transfer Characteristics of a Fluid Flow in Multi Tube Heat Exchanger Fitted with Perforated Fins
...Show More Authors

The heat transfer and flow resistance characteristics for air flow cross over circular finned tube heat exchanger has been studied numerically and experimentally. The purpose of the study was to improve the heat transfer characteristics of an annular finned-tube heat exchanger for better performance. The study has concentrated on the effect of the number of perforations and perforations shapes on the heat transfer and pressure drop across a staggered finned tube heat exchanger. The Numerical part of present study has been performed using ANSYS Fluent 14.5 using SST Turbulent model, while the experimental study consist from a test rig with different models of heat exchangers and all required measurement devices were build

... Show More
View Publication Preview PDF
Publication Date
Mon Apr 01 2019
Journal Name
Biochemical & Cellular Archives
The impact of follicular fluid growth differentiation factor 8 levels on IVF /ICSI outcomes
...Show More Authors

Clinical index is needed to predict the outcome of pregnancy after in vitro fertilization/intracytoplasmic sperm injection-embryo transfer (IVF/ICSI-ET) for infertile patients. Growth differentiation factor-8 (GDF-8), also known as myostatin, is one of transforming growth factor-â superfamily localized in antral follicles in normal and PCOS ovaries but its function in female reproductive system is still unknown. Aim of the study is to assess the correlation between levels of GDF8 in follicular fluid (FF) with outcomes of in vitro fertilization (IVF/ICSI) in women with and without PCOS. A prospective case control study was performed enrolling (40) patients with PCOS and (40) non-PCOS women (male infertility) undergoing IVF/ICSI. The collect

... Show More
Scopus (3)
Scopus
Publication Date
Wed Jan 01 2014
Journal Name
The Scientific World Journal
Heat Transfer Enhancement of Laminar Nanofluids Flow in a Circular Tube Fitted with Parabolic-Cut Twisted Tape Inserts
...Show More Authors

Numerical investigation has been carried out on heat transfer and friction factor characteristics of copper-water nanofluid flow in a constant heat-fluxed tube with the existence of new configuration of vortex generator using Computational Fluid Dynamics (CFD) simulation. Two types of swirl flow generator: Classical twisted tape (CTT) and Parabolic-cut twisted tape (PCT) with a different twist ratio (y= 2.93, 3.91 and 4.89) and different cut depth (w= 0.5, 1.0 and 1.5 cm) with 2% and 4% volume concentration

... Show More
View Publication
Scopus (38)
Crossref (30)
Scopus Clarivate Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Building Engineering
Discharge performance assessment of a vertical double-pipe latent heat storage unit equipped with circular Y-shaped fins
...Show More Authors

This paper aims to study the effect of circular Y-shaped fin arrangement to improve the low thermal response rates of a double-tube heat exchanger containing Paraffin phase change material (PCM). ANSYS software is employed to perform the computational fluid dynamic (CFD) simulations of the heat exchanger, including fluid flow, heat transfer, and the phase change process. The optimum state of the fin configuration is derived through sensitivity analysis by evaluating the geometrical parameters of the Y-shaped fin. For the same height of the fins (10 mm), the solidification time is reduced by almost 22%, and the discharging rate is enhanced by almost 26% using Y-shaped fins compared with the straight fins. The results demonstrate that the sol

... Show More
View Publication
Scopus (54)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sun Feb 02 2025
Journal Name
Engineering, Technology & Applied Science Research
A Numerical Study of Concrete Composite Circular Columns encased with GFRP I-Section using the Finite Element Method
...Show More Authors

This paper presents ABAQUS simulations of fully encased composite columns, aiming to examine the behavior of a composite column system under different load conditions, namely concentric, eccentric with 25 mm eccentricity, and flexural loading. The numerical results are validated with the experimental results obtained for columns subjected to static loads. A new loading condition with a 50 mm eccentricity is simulated to obtain additional data points for constructing the interaction diagram of load-moment curves, in an attempt to investigate the load-moment behavior for a reference column with a steel I-section and a column with a GFRP I-section. The result comparison shows that the experimental data align closely with the simulation

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Dec 27 2017
Journal Name
Al-khwarizmi Engineering Journal
The Effect of Restriction Shape On Laminar Natural Convection Heat Transfer In A Vertical Circular Tube
...Show More Authors

Natural convection heat transfer is experimentally investigated for laminar air flow in a vertical circular tube by using the boundary condition of constant wall heat flux in the ranges of (RaL) from (1.1*109) to (4.7*109). The experimental set-up was designed for determining the effect of different types of restrictions placed at entry of heated tube in bottom position, on the surface temperature distribution and on the local and average heat transfer coefficients. The apparatus was made with an electrically heated cylinder of a length (900mm) and diameter (30mm). The entry restrictions were included a circular tube of same diameter as the heated cylinder but with lengths of (60cm, 120cm), sharp-edge and

... Show More
View Publication Preview PDF