Abstractin adult typical atrioventricular nodal reentrant tachycardia (AVNRT) consider most common paroxysmalsupraventricular tachycardia. Dual pathway idea still accepted and used widely and commonly. According tothe guide line, ablations of slow pathway still the first treatment with good success rate.Identify the electrophysiological difference of atrioventricular nodal pathways pre and post ablation.Electrophysiological study was done to 54 patients with only typical type AVNRTs; they were 40 (74%)females and 14 (26%) males. Divided into two groups G1 with 38 patients (70.4%) having one pathway andG2 with 16 patients (29.6%) with multiple pathway. After induction we study the clinical andelectrophysiological feature of tachycardia and showed faster tachycardia in G1 than G2 (330 ±56 versus 430±67). And the time per minute to achieve ablation or end point more in G2 than G1 (82±12.4 G2 versus71±11.6 G1) with more energy applied in G2 versus G1 (12.4± 4.8 versus 6.3± 3.2). Complete ablation of theslow pathway was achieve in 37(69%) of total patients and only modulation occur in 17 (31%) with variationbetween two groups. And block not recorded in this study.In patient with typical AVNRTs there is percentage of multiple AV pathways 29.6%, and during EPprocedure those need good interpretation, analysis of tachycardia after induction, pre and post ablation, andalso they need more time and energy for elimination of slow pathway as well as the used of mapping system tolocalized the His area before ablation is of value to prevent AV nodal injury (PDF) Dual and Multiple AV Nodal Pathways, What is The Deference in Typical Atrioventricular Nodal Reentrant Tachycardia. Available from: https://www.researchgate.net/publication/361710553_Dual_and_Multiple_AV_Nodal_Pathways_What_is_The_Deference_in_Typical_Atrioventricular_Nodal_Reentrant_Tachycardia [accessed Sep 01 2022].
This experimental study demonstrates the gable-reinforced concrete beams’ behavior with several number of openings (six and eight) and posts’ inclination, aimed to find the strength reduction in this type of beam. The major results found are: for the openings extending over similar beam length it is better to increase the number of posts (openings),
Abstract Background: The human epidermal growth factor receptor 2(HER2) proto-oncogene is overexpressed or amplified in approximately 15%-25% of invasive breast cancers. Approximately 35% of HER2-amplified breast cancers have coamplification of the topoisomerase II-alpha (TOP2A) gene encoding an enzyme that is a major target of anthracyclines. Hence, the determination of genetic alteration (amplification or deletion) of both genes is considered as an important predictive factor that determines the response of breast cancer patients to treatment. The aims of this study are to determinate TOP2A status gene amplification in a set of Iraqi patients with breast cancer that have had an equivocal (2+) and positive HER2/neu by immunohistochemistry
... Show MoreThe objective of this research is to develop a method for applying financial derivatives in the local environment to reduce the risk of foreign exchange rate fluctuations to enhance quality of accounting profits through Financial reporting to local units In accordance with international financial reporting standards, To accomplish this objective was selected a sample of Iraqi units exposed to the risk of fluctuations in foreign currency rates, As the research found:
- many companies and banks in the local environment a lot of losses due to fluctuations in foreign currency exchange rates.
- that financial derivatives in the Iraqi environment represent
Sewer sediment deposition is an important aspect as it relates to several operational and environmental problems. It concerns municipalities as it affects the sewer system and contributes to sewer failure which has a catastrophic effect if happened in trunks or interceptors. Sewer rehabilitation is a costly process and complex in terms of choosing the method of rehabilitation and individual sewers to be rehabilitated. For such a complex process, inspection techniques assist in the decision-making process; though, it may add to the total expenditure of the project as it requires special tools and trained personnel. For developing countries, Inspection could prohibit the rehabilitation proceeds. In this study, the researchers propos
... Show MoreMulti-carrier direct sequence code division multiple access (MC-DS-CDMA) has emerged recently as a promising candidate for the next generation broadband mobile networks. Multipath fading channels have a severe effect on the performance of wireless communication systems even those systems that exhibit efficient bandwidth, like orthogonal frequency division multiplexing (OFDM) and MC-DS-CDMA; there is always a need for developments in the realisation of these systems as well as efficient channel estimation and equalisation methods to enable these systems to reach their maximum performance. A novel MC-DS-CDMA transceiver based on the Radon-based OFDM, which was recently proposed as a new technique in the realisation of OFDM systems, will be us
... Show MoreIn current study a computation fluid dynamic (CFD) technique was used to investigate the effect of groynes shape and spacing on the scour pattern and the maximum scour depth in open channel flow. CFD model have been validated throughout comparing the numerical results with three previous experimental studies for a single groyne located in open channel with three different shapes (L, quadrant, and parabola shapes). The comparison revealed very good agreement between numerical results of the maximum scour depth with the results of all experimental models. Moreover, investigations of the effect of multi-groynes (three groynes and four groynes) arranged in parallel with constant spacing and also with variable spacing have been done, the
... Show MoreThe behavior and shear strength of full-scale (T-section) reinforced concrete deep beams, designed according to the strut-and-tie approach of ACI Code-19 specifications, with various large web openings were investigated in this paper. A total of 7 deep beam specimens with identical shear span-to-depth ratios have been tested under mid-span concentrated load applied monotonically until beam failure. The main variables studied were the effects of width and depth of the web openings on deep beam performance. Experimental data results were calibrated with the strut-and-tie approach, adopted by ACI 318-19 code for the design of deep beams. The provided strut-and-tie design model in ACI 318-19 code provision was assessed and found to be u
... Show More