Preferred Language
Articles
/
5HhzQqABuRolNscLdO1m
Thermo-hydraulic performance improvement of a triangular solar air collector using homogeneous and paired-graded metal foam configurations
...Show More Authors

A numerical investigation was performed on triangular solar air collectors by integrating unique layouts of triangular and alternating triangular copper metal foams with graded and non-graded pore densities. A three-dimensional CFD model was established to solve the governing equations of coupled systems for porous and non-porous domains. The two-energy-equations model was implemented to simulate heat transfer in porous media. The mathematical model was validated with numerical and experimental tests, with maximum mean absolute percentage error of 5% and 7%, respectively. To compromise heat transfer improvement with pressure losses, a partial metal foam insertion was adopted, covering 10% to 25% of the air duct volume. The findings indicate a significant enhancement compared to conventional design, particularly for the third triangular metal foam sample characterized by high pore density and elevated permeability. Improved mixing, augmented heat exchange surface area, and localized turbulence intensification contributed to the noted gains in performance. The findings confirm that the spatial distribution and graded pore densities of metal foams are a promising approach for improving performance. Furthermore, the alternating configuration facilitated flow redistribution while mitigating excessive pressure penalties. Thermal and thermo-hydraulic efficiencies, as well as the performance evaluation criterion, rose from 63.22% to 85.39%, 53.69% to 71.91%, and 2.70 to 5.02, respectively, when the metal foam volume fraction was increased from 10% to 25%. Such systems can be integrated into building as part of energy transition scenario to decrease carbon dioxide emissions and improve overall energy efficiency.

Crossref
View Publication
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study on Solar Air Heating
...Show More Authors

Abstract

 

A new type of solar air heater was designed, fabricated, and tested in Baghdad, Iraq winter conditions. The heater consists of two main parts. The horizontal section was filled with the black colored iron chip while the vertical part has five pipes filled with Iraqi paraffin wax. A fan was fixed at the exit of the air. Two cases were studied: when the air moved by natural convection and when forced convection moved it. The studied air heater has proven its effectiveness as it heated the air passing through it to high temperatures. The results manifest that using little air movement makes the temperatures, stored energies, and efficiencies of the two studied cases converge

... Show More
View Publication Preview PDF
Crossref (9)
Crossref
Publication Date
Fri Nov 11 2011
Journal Name
Thesis
Performance Analysis of a New Compact Magneto-Rheological Proportional Control Valve for Hydraulic Actuation Using FEM and Experimental Approach
...Show More Authors

One of the main parts in hydraulic system is directional control valve, which is needed in order to operate hydraulic actuator. Practically, a conventional directional control valve has complex construction and moving parts, such as spool. Alternatively, a proposed Magneto-rheological (MR) directional control valve can offer a better solution without any moving parts by means of MR fluid. MR fluid consists of stable suspension of micro-sized magnetic particles dispersed in carrier medium like hydrocarbon oil. The main objectives of this present research are to design a MR directional control valve using MR fluid, to analyse its magnetic circuit using FEMM software, and to study and simulate the performance of this valve. In this research, a

... Show More
Publication Date
Sat Nov 01 2025
Journal Name
Iop Conference Series: Earth And Environmental Science
Improving the Hydraulic Performance of Bani-Hassan Canal by Using Submerged Weir
...Show More Authors
Abstract<p> A submerged weir is a hydraulic structure utilized to control flow in canals and rivers. Water scarcity is a persistent issue in Iraq, especially during the dry season when irrigation withdrawals reduce downstream water levels in canals (Water is lost from irrigation canals due to seepage, evaporation, and vegetation growth). The final section of the Bani Hassan Canal experiences significant drops in water surface (WS) levels, negatively impacting irrigation efficiency. This study addresses that gap by investigating the use of submerged weirs to enhance water distribution and raise WS in the final 6 km segment of the canal. A one-dimensional (1D) hydraulic mode</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Thu Jan 08 2026
Journal Name
Heat Transfer
Numerical Analysis of Mixed Convection in Vented Curved Cavity With a Metal Foam Layer
...Show More Authors
ABSTRACT<p>Heat transfer applications usually contemplated day‐to‐day are primarily spotlighted on mixed convection, such as solar collector heating arrangements, electronic cooling, and drying processes. Enhancing convection heat transmission in such appliances can be achieved by inserting porous media, inflow loci, and/or line geometry. In the present paper, convection heat transmission inside a vented curved cavity () with an inserted metal foam layer ( PPI and 0.9% porosity) saturated with water was accomplished. The bottom cavity wall was discretely heated at a constant hot temperature, and the curved wall was kept at a constant cold temperature. Governing equations comprising cont</p> ... Show More
View Publication
Scopus Crossref
Publication Date
Sun Mar 01 2026
Journal Name
Journal Of Engineering
Heat Dissipation Performance of High-Power CPUs using Finned Copper Foam Heat Sinks
...Show More Authors

Thermal management has become a major issue in the latest high performance computing machines because high CPU temperatures result in inefficient performance and decreased hardware life span. In this work, the cooling performance of a finned metal foam heat sink (FMFHS) was examined. The pore density values of tested copper metal foam (CMF) samples with different values of PPI 5, 10 and 20, with a constant porosity of 90%. For reference, these samples were measured by a conventional Aluminum plate-fin heat sink (CHS). The work was performed under experimental conditions in which air directed over the heat sink surface at air velocities (2.5, 3.0 and 3.5 m/s). The environmental temperature was fixed at 27 °C. Findings

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Roughness Effect on Thermo-Elasto-Hydrodynamic Performance of a 170ᵒ -Arc Partial Journal Bearing
...Show More Authors

In the current analysis, the effects of circumferential scratches along the inner surface of a 170ᵒ -arc partial journal bearing has been numerically investigated. Their impact on the thermo-elasto-hydrodynamic performance characteristics, including maximum pressure, temperature, deformation, and stress, has been examined thoroughly. The ANSYS Fluent CFD commercial code was employed to tackle the iterative solution of flow and heat transfer patterns in the fluid film domain. They are then applied to the ANSYS Static Structure solver to compute the deformation and stress resulted in the solid bearing zone. A wide range of operating conditions has been considered, including the eccentricity ratio ( ) and scratch depth (

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Wed May 01 2019
Journal Name
Journal Of Engineering
Theoretical Analysis of Seepage through Homogeneous and Non-homogeneous Saturated-Unsaturated Soil
...Show More Authors

In this research, the program SEEP / W was used to compute the value of seepage through the homogenous and non-homogeneous earth dam with known dimensions. The results show that the relationship between the seepage and water height in upstream of the dam to its length for saturated soil was nonlinear when the dam is homogenous. For the non-homogeneous dam, the relationship was linear and the amount of seepage increase with the height of water in upstream to its length. Also the quantity of seepage was calculated using the method of (Fredlund and Xing, 1994) and (Van Genuchten, 1980) when the soil is saturated – unsaturated, the results referred to that the higher value of seepage when the soil is saturated and the lowe

... Show More
View Publication Preview PDF
Crossref (13)
Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Experimental Study on Double-Pass Solar Air Heater with and without using Phase Change Material
...Show More Authors

In this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant

... Show More
View Publication Preview PDF
Crossref (25)
Crossref
Publication Date
Sat Jul 01 2023
Journal Name
Journal Of Engineering
Performance of Solar Adsorption Cooling System Using Methanol and Activated Carbon as a Working Pair
...Show More Authors

The need for renewable energy sources is higher than ever due to rising global warming, climate change, and ozone depletion. For refrigeration and air conditioning applications, adsorption refrigeration systems are viable alternatives cooling techniques. This study is a topic and part of the M.Sc. thesis. A field solar-powered ice maker unit was created, studied, tested, and evaluated on the 13th and 30th of May, 2022. Activated carbon and methanol pair was used to set up a refrigeration system in Baghdad (Al Dora). Experimental tests were carried out outdoors to determine the coefficient of performance COP and specific cooling power SCP of the system. The results showed that the lowest temperature

... Show More
View Publication Preview PDF
Scopus (8)
Crossref (7)
Scopus Crossref
Publication Date
Sat Apr 01 2017
Journal Name
Applied Energy
Melting enhancement in triplex-tube latent heat energy storage system using nanoparticles-metal foam combination
...Show More Authors

View Publication
Scopus (309)
Crossref (309)
Scopus Clarivate Crossref