The term "tight reservoir" is commonly used to refer to reservoirs with low permeability. Tight oil reservoirs have caused worry owing to its considerable influence upon oil output throughout the petroleum sector. As a result of its low permeability, producing from tight reservoirs presents numerous challenges. Because of their low permeability, producing from tight reservoirs is faced with a variety of difficulties. The research aim is to performing hydraulic fracturing treatment in single vertical well in order to study the possibility of fracking in the Saady reservoir. Iraq's Halfaya oil field's Saady B reservoir is the most important tight reservoir. The diagnostic fracture injection test is determined for HF55using GOHFER software. Models for petrophysics and geology were calibrated using the diagnostic fracture injection test results after the petrophysical and geomechanical parameters of the rock have been determined. The HF55 vertical well, which penetrates the Saady reservoir, has well logs that have been used to evaluate the petrophysical and geomechanical parameters. These estimates have been supported by findings from the diagnostic fracture injection test through the utilization of standard equations and correlations. The findings of the diagnostic fracture injection test, often known as the diagnostic fracture injection test, are very compatible with the findings of the well logs. The diagnostic fracture injection test pre-falloff test event was examined to determine the instantaneous shut-in pressure and fracture gradient. In the meantime, Closure pressure, process zone stress, fracturing fluid efficiency, closure gradient, critical fissure opening pressure, storage correction factor, permeability, and pressure-dependent leak-off coefficient were all determined using the G function on plot. With the help of a specific software, the petrophysical and geomechanical properties of a single vertical well [HF55] was found. Saady B reservoir's upper and lower sections, along with it are therefore predicted to have the full range of petrophysical and geomechanical features. With the use of DFIT analysis, these features serve as the foundation for developing fracturing models.
The settlement rate and pore water pressure dissipation rate are mainly controlled by the permeability of soil. Both laboratory and field tests show that the permeability is varied during the loading and consolidation process. It is known that consolidation process is accompanied by decrease in void ratio which leads to decrease in the coefficient of permeability. The importance of the decrease of the coefficient of permeability on the time rate of settlement and pore water pressure needs to be investigated.
This paper takes into account the change in coefficient of permeability during consolidation and studies its effect on consolidation characteristics of a clay layer. The finite element method is used in the analysis and the packag
To ascertain the stability or instability of time series, three versions of the model proposed by Dickie-Voller were used in this paper. The aim of this study is to explain the extent of the impact of some economic variables such as the supply of money, gross domestic product, national income, after reaching the stability of these variables. The results show that the variable money supply, the GDP variable, and the exchange rate variable were all stable at the level of the first difference in the time series. This means that the series is an integrated first-class series. Hence, the gross fixed capital formation variable, the variable national income, and the variable interest rate
... Show MoreA total of 41 patients with gastro duodenal symptoms (show signs of inflammation with or without duodenal ulcer) . 21 males (51.2%) and 20 female (48.8%) with an average age 0f (20 – 80) years old under going gastrointestinal endoscopy at Baghdad teaching hospital in internal disease clinical laboratory , between (February – June) 2009 . Biopsies specimen of antrum , gastric fundus ,& duodenal bulb were examined by the following methods (rapid urease test , Giemsa stain section to detect bacteria , & Haematoxilin and Eosin stained section for pathological study which are considered the gold standard methods , sera or plasma from these patients were tested by immunochromotography (ICM),serological m
... Show MoreAsmari is the main productive reservoir in Abu Ghirab oilfield in the south-east part of Iraq. It has history production extends from 1976 up to now with several close periods. Recently, the reservoir suffers some problems in production, which are abstracted as water production rising with oil production declining in most wells. The water problem type of the field and wells is identified by using Chan's diagnostic plots (water oil ratio (WOR) and derivative water oil ratio (WOR') against time). The analytical results show that water problem is caused by the channeling due to high permeability zones, high water saturation zones, and faults or fracturing. The numerical approach is also used to study the water movement inside the reser
... Show MoreAsmari is the main productive reservoir in Abu Ghirab oilfield in the south-east part of Iraq. It has history production extends from 1976 up to now with several close periods. Recently, the reservoir suffers some problems in production, which are abstracted as water production rising with oil production declining in most wells. The water problem type of the field and wells is identified by using Chan's diagnostic plots (water oil ratio (WOR) and derivative water oil ratio (WOR') against time). The analytical results show that water problem is caused by the channeling due to high permeability zones, high water saturation zones, and faults or fracturing. The numerical approach is also used to study the water movement insi
... Show More
This paper deals with a method called Statistical Energy Analysis that can be applied to the mechanical and acoustical systems like buildings, bridges and aircrafts …etc. S.E.A as a tool can be applied to the resonant systems in the circumstances of high frequency or/and complex structure». The parameters of S.E.A such as coupling loss factor, internal loss factor, modal density and input power are clarified in this work ; coupled plate sub-systems and explanations are presented for these parameters. The developed system is assumed to be resonant, conservative, linear and there is an equipartition of energy between all the resonant modes within a given frequency band in a given sub-system. The aim of th
... Show MoreThe current work is focused on the rock typing and flow unit classification for reservoir characterization in carbonate reservoir, a Yamama Reservoir in south of Iraq (Ratawi Field) has been selected, and the study is depending on the logs and cores data from five wells which penetrate Yamama formation. Yamama Reservoir was divided into twenty flow units and rock types, depending on the Microfacies and Electrofacies Character, the well logs pattern, Porosity–Water saturation relationship, flow zone indicator (FZI) method, capillary pressure analysis, and Porosity–Permeability relationship (R35) and cluster analysis method. Four rock types and groups have been identified in the Yamama formation de