Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concentration, basic medium, flow rate, sample volume, purge time, and delay coil have been investigated. The dynamic range of MFA was 0.2 to 2 mmol.L-1; 0.5 to 2.3 mmol.L-1 with linearity percentage (% r2) 98.92 and 99.83%, for Rh-6G and CLB, respectively. Limit of detection at a minimum concentration in calibration curve 189.34 and 199.89 ng/sample, for Rh-6G and CLB, respectively. The comparison of developed methods with the classical method (UV-vis spectrophotometry) was achieved. The proposed methods were successfully applied for the determination of MFA in the pharmaceutical samples and can be used as an alternative method.
The Paleocene benthic foraminiferal zonation of the Umm Er Rhadhuma Formation from the borehole (K.H 12/7), South Anah City (Western Iraq), has been re-studied and re-analyzed precisely based on the large benthic foraminifera (LBF). They are represented by two biozone Rotorbinella hensoni Partial Range Zone, recorded from the Lower and middle parts of the Umm Er Rhadhuma Formation and Lockhartia praehaimei Partial Range Zone determined Uppermost of this unit, and dated to be the Selandian – Thanetian stage. Almost all the biogenic (micro and macro) and non-biogenic constituents, including large benthic foraminifera, Algae, Echinoderm, Bryozoans, Oyster, Gastropod fragments, and peloids, in addition to lithofacies types, indicate t
... Show MoreABSTRACT Backgrounds: Maxillary canine impaction is complicated and time consuming to treat, for being highly diverse in inclination and location; it may be a companied by root resorption of the neighboring teeth. CBCT has been used for its' diagnostic reliability in localization of impacted canine and revealing its' serious local complications. Objectives: Localization of maxillary impacted canine using cone beam computed tomography for assessment of angulation, distance from occlusal plane, alveolar width and proximity to adjacent teeth. Subjects and Methods: The study sample was 33 subjects 16 females and 17 males attended to Al-Wasitti general hospital in Baghdad city-Oral and maxillofacial radiology department for CBCT scan investigati
... Show MoreThe paper deals with the marked vocabulary of Russian and Arabic language, and the extrapolated to the phraseological layer of the mentioned language systems. Specificity of the functioning of this process is presented against the backdrop of the peculiarities of the existence of Russian and Arabic languages. Attention is focused on the fact that linguistic markers should be considered as a kind of keys that represent the specificity of the experience of being experienced by an individual in ontological reality. It is asserted that marking can be revealed practically at all levels of the language polysystem, but it is especially productive on its lexical layer, in particular, on the basis of lexicology and ph
... Show MoreInfrared photoconductive detectors working in the far-infrared region and room temperature were fabricated. The detectors were fabricated using three types of carbon nanotubes (CNTs); MWCNTs, COOH-MWCNTs, and short-MWCNTs. The carbon nontubes suspension is deposited by dip coating and drop–casting techniques to prepare thin films of CNTs. These films were deposited on porous silicon (PSi) substrates of n-type Si. The I-V characteristics and the figures of merit of the fabricated detectors were measured at a forward bias voltage of 3 and 5 volts as well as at dark and under illumination by IR radiation from a CO2 laser of 10.6 μm wavelengths and power of 2.2 W. The responsivity and figures of merit of the photoconductive detector
... Show More
The topological parameters of the metal-metal and metal-ligand bonding interactions in a trinuclear tetrahydrido cluster [(Cp*Co) (CpRu)2 (μ3-H) (μ-H)3]1 (Cp* = η5 -C5Me4Et), (Cp = η5 -C5Me5), was explored by using the Quantum Theory of Atoms-in-Molecules (QTAIM). The properties of bond critical points such as the bond delocalization indices δ (A, B), the electron density ρ(r), the local kinetic energy density G(r), the Laplacian of the electron density ∇2ρ(r), the local energy density H(r), the local potential energy density V(r) and ellipticity ε(r) are compared with data from earlier organometallic system studies. A comparison of the topological processes of different atom-atom interactions has become possible than
... Show MoreDespite Iraq's possession of the energies material, human and agricultural resources and great economic but that contribution of the agricultural sector in the total gross fixed capital formation and gross domestic product in the Iraqi economy remained low and declining continuously since the nineties of the last century, as well as the inability of agricultural production to meet the country's needs of food . The food gap increased strategic food crops until it reached 1049 thousand tons in 2010. On this basis, there is a need to study and analysis the behavior of the function of gross fixed capital format
... Show MoreThe aim of the study was to evaluate the efficacy of diode laser (λ=940 nm) in the management of gingival hyperpigmentation compared to the conventional bur method. Materials and methods: Eighteen patients with gingival hyperpigmentation were selected for the study with an age between 12-37 years old. The site of treatment was the upper gingiva using diode laser for the right half and the conventional method for the left half. All patients were re-evaluated after the following intervals: 3 days, 7 days, 1 month and 6 months post-operation. Pain and functions were re-evaluated in each visit for a period of 1 day, 3 days and 1 week post-operation. Laser parameters included 1.5 W in continuous mode with an initiated tip (400 μm) placed in
... Show MoreTwo Schiff bases, namely, 3-(benzylidene amino) -2-thioxo-6-methyl 2,5-dihydropyrimidine-4(3H)-one (LS])and 3-(benzylidene amino)-6-methyl pyrimidine 4(3H, 5H)-dione(LA)as chelating ligands), were used to prepare some complexes of Cr(III), La(III), and Ce(III)] ions. Standard physico-chemical procedures including metal analysis M%, element microanalysis (C.H.N.S) , magnetic susceptibility, conductometric measurements, FT-IR and UV-visible Spectra were used to identify Metal (III) complexes and Schiff bases (LS) and (LA). According to findings, a [Cr(III) complex] showed six coordinated octahedral geometry, while [La(III), and Ce(III) complexes]were structured with coordination number seven. Schiff's bases a
... Show More