The objective of the present work was to estimate water requirements and water use efficiency for Broccoli under normal irrigation conditions and sewage irrigation. Field experiment was carried out during the season 2018 at station/Sulaimni agricultural station/Bakrajo –College of Agricultural Sciences. The experiment included three treatments: River water irrigation in all season growth (I1), Sewage water irrigation in all season growth (I2), Alternate irrigation (one river irrigation followed by two sewage water irrigation) in all season growth (I3). The experimental Design was Randomized Complete Block Design (RCBD) with three replications. Broccoli planted under surface irrigation system. Mean irrigation requirement for irrigation management scheduling gave water consumptive use values 442, 432 and 427 mm for river water, sewage water and alternate irrigation, respectively. Average yield Broccoli plant was 32.67, 40.25 and 46.73 Ton ha−1 for river water irrigation, sewage water irrigation and alternate irrigation, respectively. High performance of Alternate irrigation application was mentioned by plant height which record 39, 42 and 46 cm; head diameter 21, 25 and 28 cm; leaf area 306, 329 and 349 cm2 and number of leaves 18, 21 and 22 for river water irrigation, sewage water irrigation and alternate irrigation, respectively. WUEc were 7.39, 9.32 and 10.94 kg m−3 for river, sewage and alternate treatments, respectively. The results showed that the concentrations of these elements did not reach the critical limits in the fruits for all irrigation treatments. This is a positive and good result due to the increase in rainfall rates in this season led to weak accumulation of heavy metals in the soil and poor absorption by the plant.
The research’s main goal is to investigate the effects of using magnetic water in concrete mixes with regard to various mechanical properties such as compressive, flexural, and splitting tensile strength. The concrete mix investigated was designed to attain a specified cylinder compressive strength (30 MPa), with mix proportions of 1:1.8:2.68 cement to sand to crushed aggregate. The cement content was about 380 kg/m3, with a w/c ratio equal to 0.54, sand content of about 685 kg/m3, and gravel content of about 1,020 kg/m3. Magnetic water was prepared via passing ordinary water throughout a magnetic field with a magnetic intensity of 9,000 Gauss. The strength test
Resumen:
El horóscopo que es una predicción deducida de la posición de los astros del sistema solar y de los signos de Zodiaco, intenta no sólo predecir el futuro, sino también influir en el comportamiento del lector, orientándolo para que actúe adecuadamente y la invitación a actuar ante ese futuro que se aconseja mediante imperativos, perífrasis y otros recursos lingüísticos. Los horóscopos se caracterizan por su gran popularidad que existen en periódico o revista en columnas enteras dedicadas al tema, en donde se detallan la influencia que tendrá el día o el mes de cada uno de los signos correspondientes al zodíaco, siempre teniendo en cuenta la posici
... Show MoreAbstract
Objective(s): to Evaluation of Parents’ Knowledge about Nutritional Management of kids with Phenylketonuria; to Identify the association between parents’ Knowledge about nutritional management then their demographic variables of fathers, mothers (parents age, residence then socioeconomic position).
Methodology: A non-experimental project; was accompanied on parents of phenylketonuria kid in Baghdad town since the period 3 June to 5 October 2022. A Non-probability sample (convenience) of 35 PKU children and their parents (father and mother) was selected Purposively from the hospitals that are select for the study. A survey is built for the purpose of the educa
... Show MoreThe current study aims to identify the feeling of job alienation and organizational commitment among free lecturers in secondary schools, as well as to identify the significance of the differences in the feeling of job alienation according to the gender and the significance of the differences in organizational commitment according to the gender. It also aims to identify the correlation between the feeling of job alienation and organizational commitment. To achieve the objectives of the research, the researcher developed two scales: one consisted of (24) items to measure the vacancy in job alienation and the other consisted of (24) items to measure the organizational commitment. The two tools were applied to a sample of (200) male and fem
... Show MoreOne of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model at elevated t
... Show MoreOne of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model a
... Show MoreOne of the most important parameters determining structural members' durability and strength is the fire flame's influence and hazard. Some engineers have advocated using advanced analytical models to predict fire spread impact within a compartment and considering finite element models of structural components to estimate the temperatures within a component using heat transfer analysis. This paper presented a numerical simulation for a reinforced concrete beam’s structural response in a case containing Water Absorbing Polymer Spheres (WAPS) subjected to fire flame effect. The commercial finite element package ABAQUS was considered. The relevant geometrical and material parameters of the reinforced concrete beam model at elevated t
... Show More