New nanotechnology-based approaches are increasingly being investigated for enhanced oil recovery (EOR), with a particular focus on heavy oil reservoirs. Typically, the addition of a polymer to an injection fluid advances the sweep efficiency and mobility ratio of the fluid and leads to a higher crude oil recovery rate. However, harsh reservoir conditions, including high formation salinity and temperature, can limit the performance of such polymer fluids. Recently, nanofluids, that is, dispersions of nanoparticles (NPs) in a base fluid, have been recommended as EOR fluids; however, such nanofluids are unstable, even under ambient conditions. In this work, a combination of ZrO2 NPs and the polyacrylamide (PAM) polymer (ZrO2 NPs–PAM) was used to formulate a novel nanopolymer injection solution for EOR applications to overcome the limitations of simple PAM solutions by the in situ reservoir conditions including high temperature and salinity. A series of measurements were comprehended at controlled pH values to measure the stability and rheological properties of NPs–PAM combinations at different temperatures, salinities, NP concentrations, and shear rates. It is depicted from the results that a higher salinity decreased the viscosity of the polymer formulation. However, ZrO2 NPs–PAM combinations reduced the effect of increased salinity on viscosity, which is essential for EOR applications. Furthermore, at low and medium shear rates, which are more relevant to the flow scenarios in oil reservoirs, ZrO2 NPs–PAM exhibited a higher viscosity than the PAM solution at the same pH and salinity. In contrast, at higher shear rates, the viscosity of ZrO2 NPs–PAM was less than that of the sole PAM solution. Mechanistically, an increased shear rate endorsed the adsorption of polymer molecules onto the surface of NPs, foremost to a lesser polymer concentration in the solution. Moreover, although ZrO2 nanodispersion was unstable at all NPs and salt concentrations, ZrO2 NPs–PAM was stable over an extensive range of salinities and temperatures. The results suggested that ZrO2 NPs–PAM is more suitable than the sole polymer or NP solutions for EOR projects.
It was aimed to investigate the compressibility, compactibility, powder flow and tablet disintegration of a new excipient comprising magnesium (Mg) silicate co-processed (5%–85% w/w) onto chitin, microcrystalline cellulose (MCC) and starch as the hydrophilic polymers of interest. Initially, the mechanism of tablet disintegration was studied by measuring water infiltration rate, moisture sorption, swelling capacity and hydration ability. Moreover, the powders compression behavior was carried out by applying Kawakita model of compression analysis in addition to porosity and radial tensile strength measurements. In vitro drug release of compacts made of 400 mg ibuprofen and 300 mg of the hydrophilic polymers containing 30% w/w Mg silicat
... Show MoreAutorías: Ghassan Adeeb Abdulhasan, Falih Hashim Fenjan, Hussein Jabber Abood. Localización: Revista iberoamericana de psicología del ejercicio y el deporte. Nº. 3, 2022. Artículo de Revista en Dialnet.
In this work the interaction of plasma jet with water and hydrogen peroxide liquids used for assisted teeth bleaching by plasma jet had been study. A homemade plasma jet system was used. The plasma jet supply by 15 W electrical power generated by high voltage power supply of 9.6 kV peak to peak and frequency of 33 kHz .this power supply generate high electric field on electrodes that would be enough to ionize the argon gas. Some important agents were study such as the effect of the Ar gas flow rates on the length of the plasma jet, the influence of plasma jet on some properties of water and two hydrogen peroxide concentrations 25 % and 30 % like pH, conductivity and liquid temperature for different exposure time. The liquids temperature
... Show MoreThe effects of scattering and secondary radiation generated inside the material on dose equivalent rate where studied using Co60 and Cs137 sources of activity (199.8 , 177.6) MBq , respectively for different thicknesses of Al , Pb and Pb- glass . The results showed that the equivalent rate increases when the effect of scattering was included for Al and Pb shields with cobalt-60 source of energy 1.25 MeV ; and decreases for Pb shield with Cs-137 source of energy 0.662MeV .The results showed also that the atomic number of The material effects the dose equivalent rate . The Pb-glass shield was found to be more efficient in absorption than other shields.
In this research, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). An optimization procedure using reflective (~85%) InSb etalon (~50µm) thick is described. For this etalon with a (50 µm) spot diameter beam, the minimum switching power is (~0.078 mW) and switching time is (~150 ns), leading to a switching energy of (~11.77 pJ) for this device. Also, the main role played by the temperature to change the etalon characteristic from nonlinear to linear dynamics.
The objective of the research is to uncover the effect of the strategy of Quranic verses in the collection of science and systemic intelligence for second-grade students. The research sample consisted of (48) students of second grade students in the middle of Al Rasheed Boys School of the second Karkh Directorate, Distribution in the two divisions, Division of (b) and experimental group that studied strategy of Quranic verses, and the Division (a) control group which studied the regular way, and results indicated a statistically significant differences for the experimental group students studied using the strategy Verses in systemic intelligence collection.
Background: Tubal ligation, recognized as a surgical intervention that ensures permanent contraception, has established itself as an option for women seeking a definitive solution for family planning. Objective: To assess the psychosexual implications of tubal ligation in a sample of women in Baghdad, Iraq. Methods: A prospective cohort study was conducted in a teaching hospital for 2 years, from the first of January 2022 to the end of December 2023, in which 203 women who underwent tubal ligation were included. Results: In the present study, we found that 158 (77.8%) had no depression, mild depression presented in 27 (13.3%), and moderate depression in only 15 (7.4%). While 163 (80.3%) of women did not suffer from anxiety, 32 (15.8
... Show More