Core decompression is one of the commonest used techniques in the handling of osteonecrosis of the pre-collapsed head of the femur. Core decompression had succeeded in preserving the hip joint and delaying the requisite for total hip replacement, but it had failed in the induction of osteogenesis in the necrotic area, thus augmenting core decompression with biological agents to induce osteogenic activity. To assess the effects of platelet-rich plasma in non-traumatic avascular necrosis of the hip joint (early stage) after core decompression. Interventional comparative study for twenty-four patients (32 hip joints) with AVN of the head of the femur was involved in this prospective study, and they were separated into two groups of 16 hips, group (A) treated by core decompression and PRP injection and group (B) treated by core decompression alone. There was a significant statistical difference in Harris Hip Score and Visual Analogue of the two groups at six months follow up (P<0.05), but this difference was insignificant statistically at 12 months follow up. The radiological success was better in the group (A) as compared to group (B) (13 of 16 versus 10 of 16 hips). The addition of PRP to core decompression for pre-distorted stages of the head of the femur had resulted in improved pain alleviation and functional results and had slowed the disease progression in the one year of follow up.
Background: Postoperative pain is one of the main complications following impacted mandibular third molar (IMTM) surgery. Objectives: The aim of this study was to assess the effect of the local application of bupivacaine on reducing early postoperative pain following IMTM surgery. Material and methods: A prospective, single-blinded, randomized controlled study was conducted on 40 patients who had undergone the surgical removal of an IMTM under local anesthesia. In the study group (n = 20), absorbable gelatin sponge (AGS) soaked in 3 mL of 0.5% plain bupivacaine hydrochloride was locally applied in the post-extraction socket. In the control group (n = 20), AGS soaked in 3 mL of normal saline was used. Pain intensity was assessed using a pa
... Show MoreBackground: The aim of this study was to evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic adhesive systems after exposure to aging media (water storage and acid challenge). Materials and methods: Eighty human upper premolar teeth were extracted for orthodontic purposes and randomly divided into two groups (40 teeth each): the first group in which the bonded teeth were stored in distilled water for 30 days at 37°C, and the second group in which the bonded teeth were subjected to acid challenge. Each group was further subdivided into four subgroups (10 teeth each) according to the type of adhesive system that would be bonded to metal brackets: either non-fluoride releasing adhesive (NFRA),
... Show MoreABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co
... Show MoreThe main objective of this study is to experimentally investigate the effect of the CMC polymeric drag reducer on the pressure drop occurred along the annulus of the wellbore in drilling operation and investigate the optimum polymer concentration that give the minimum pressure drop. A flow loop was designed for this purpose consist from 14 m long with transparent test section and differential pressure transmitter that allows to sense and measure the pressure losses along the test section. The results from the experimental work show that increasing in polymer concentration help to reduce the pressure drop in annulus and the optimum polymer concentration with the maximum drag reducing is 0.8 kg/m3. Also increasing in flow rate a
... Show MoreThe problem of the damage caused by terrorist acts has raised many difficulties in many countries, including Iraq, which requires the existence of a law that sets out sufficient rules for compensating the victims of terrorist acts, in order to compensate them for the harm they have not suffered. It may be difficult or impossible for them to identify causing damage, and therefore unable to obtain compensation by applying the traditional rules of liability that require proof of fault and identify the culprit. The security funds come as an appropriate alternative that pays compensation in such cases for victims to reparation for the damage they suffered. Therefore, this problem remains one of the most problems that Iraq suffers from it, which
... Show MoreThe present study aimed to look for the differences in the oxidative stress status in sera and saliva samples of type 2 diabetic Iraqi patients with and without proliferative diabetic retinopathy. As well as to look for the possibility whether this status can be measured in saliva as an alternative sample to that of serum, hence to achieve that total oxidant status, total antioxidant status and oxidative stress index were measured in both sera and saliva samples of two groups of patients with type 2 diabetes mellitus and the healthy individuals. Upon the comparison between patients without proliferative diabetic retinopathy and the control sample the results showed presence of a significant increase (p < 0.05) of total oxidant st
... Show MoreTraditional healthcare for chronic wounds and Cold Atmospheric Plasma (CAP) treatments relies on passive dressings and large-volume stationary equipment operating with open-loop systems, which severely limits their use and confines it to specialized clinical environments. To address the lack of active thermal safety mechanisms in mobile devices, this research proposes a wearable smart plasma patch equipped with a closed-loop adaptive electronic control system to ensure safe patient care and treatment at home. The smart patch integrates real-time analog biosensors to continuously monitor skin temperature and relative humidity. An algorithm running on a microcontroller dynamically adjusts the high-voltage plasma parameters using Pulse
... Show MoreTitanium alloy (Ti-6Al-4V) samples were nitrided in low pressure (1.3, 3 mbar) dc-glow discharge plasmas of nitrogen. The treating time was 5, 10 and 15 hour and the temperatures range of the samples during the nitriding process was close to 800oC. The obtained microstructures of the nitride layers were studied by x-ray diffraction and optical microscopy. The ε –Ti2N, ζ-Ti3N3-x and η-Ti3N2-x.phases were formed and addition to the solid solution of nitrogen in titanium, α (Ti,N). Micro hardness measurements exhibit an increment for the Ti-alloy specimens which nitrided at 800oC for 10 and 15h.Corrosion measurements were obtained for the Ti-6Al-4V alloy in Ringer solution after plasma nitriding. The clear improving in the corrosion r
... Show MoreThe brief description to the theory of propagation of electromagnetic waves in plasma was done. The cutoff and resonance regions have been showed. The principles of plasma heating at electron cyclotron resonance (ECRH) method have been mentioned. The numerical simulation to three different station: Tosca station in United Kingdom, ISX-B station in USA and T-10 station in Russia had been done. The optical depth and the friction of energy absorbed A have been calculated. The simulation results indicate that both and A are increase with size of the tokamak and it is possible to obtain full absorption in large tokamak.
Polyaniline (PANI) and Ag/PANI nanocomposite thin films have prepared by microwave induced plasma. The Ag powder of average particle size of 50 nm, were used to prepare Ag/PANI nanocomposite thin films. The Ag/PANI nanocomposite thin films prepared by polymerization in plasma and characterized by UV-VIS, FTIR, AFM and SEM to study the effect of silver nanoparticles on the optical properties, morphology and structure of the thin films. The optical properties studies showed that the energy band gap of the Ag/PANI (5%wt silver) decreased from 3.6 to 3.2 eV, where the substrate location varied from 4.4 to 3.4 cm from the axis of the cylindrical plasma chamber. Also the optical energy gap decreased systematically from 3.3 to 3 eV with increas
... Show More