Proxy-based sliding mode control PSMC is an improved version of PID control that combines the features of PID and sliding mode control SMC with continuously dynamic behaviour. However, the stability of the control architecture maybe not well addressed. Consequently, this work is focused on modification of the original version of the proxy-based sliding mode control PSMC by adding an adaptive approximation compensator AAC term for vibration control of an Euler-Bernoulli beam. The role of the AAC term is to compensate for unmodelled dynamics and make the stability proof more easily. The stability of the proposed control algorithm is systematically proved using Lyapunov theory. Multi-modal equation of motion is derived using the Galerkin method. The state variables of the multi-modal equation are expressed in terms of modal amplitudes that should be regulated via the proposed control system. The proposed control structure is implemented on a simply supported beam with two piezo-patches. The simulation experiments are performed using MATLAB/SIMULINK package. The locations of piezo-transducers are optimally placed on the beam. A detailed comparison study is implemented including three scenarios. Scenario 1 includes disturbing the smart beam while no feedback loop is established (open-loop system). In scenario 2, a PD controller is applied on the vibrating beam. Whereas, scenario 3 includes implementation of the PSMC+AAC. For all previously mentioned scenarios, two types of disturbances are applied separately: 1) an impulse force of 1 N peak and 1 s pulse width, and 2) a sinusoidal disturbance with 0.5 N amplitude and 20 Hz frequency. For impulse disturbance signals, the results show the superiority of the PSMC+AAC in comparison with the conventional PD control. Whereas, both the PSMC+ACC and the PD control work well in the case of a sinusoidal disturbance signal and the superiority of the PSMC is not clear.
In this work an experimental simulation is made to predict the performance of steady-state natural heat convection along heated finned vertical base plate to ambient air with different inclination angles and configurations of fin array. Two types of fin arrays namely vertical fins array and V-fins array on heated vertical base plate are used with different heights and spaces. The influence of inclination angle of the plate , configuration of fins array and fin geometrical parameters such as fin height and fin spacing on the temperature distribution, base convection heat transfer coefficient and average Nusselt number have been plotted and discussed. The experimental data are correlated to a formula between average Nusselt number versus R
... Show MoreThis paper presents experimental results regarding the behaviours of eight simply supported partially prestressed concrete beams with internally unbonded tendons, focusing particularly on the effect of three different variables: concrete compressive strength,
Background: Patients with chronic kidney
disease have different grades of sensorineural
deafness .
Objective: To study the incidence of
sensorineural hearing loss and possible contributing
factors in patients with chronic kidney disease.
Methods: A total of 100 patients with chronic
kidney disease were studied. All of them were
males. 92 of them were on regular haemodialysis
programme. Only 8 patients were on conservative
management the age range of the study patients was
18-40 year patients were divided into three groups
according to age. All patients were assessed
clinically and were evaluated by audiometry , and
analysis was made on bone conduction threshold
.The mean follow up period was 2
An effort is made to study the effect of composite nanocoating using aluminum-9%wt silicon alloys reinforced with different percentage (0.5,1,2,4)wt.% of carbon nanotubes (CNTs) using plasma spraying. The effect of this composite on corrosion behavior for AA6061-T6 by extrapolation Tafel test in sea water 3.5wt% NaCl was invested. Many specimens where prepared from AA6061-T6 by the dimension (15x15x3)mm as this first set up and other steps include coating process, X-ray diffraction and SEM examination .The results show the CNTs increase the corrosion rate of the nanocomposite coatings with increasing the weight percentage of CNTs within the Al-Si matrix. Al-9wt%Si coating layer itself has less corrosion rate if compared with both n
... Show MoreThe study was carried out to detection of H.pylori in (200) patients who attended two teaching hospitals in Baghdad. The diagnosis done by Immunochromatography methods. Stools and blood samples was taken from each patient as well as other (30) healthy control matching in their age. The study included detection the Levels of Interleukin-40 and CRP in sera of patients and control. The result indicated presence of H pylori antigen in 115 cases 59 cases of males and 51 of females, Also, the result indicated increasing levels of IL-40, cholesterol, Triglycerides, Low density lipoprotein, Very Low density lipoprotein increased significantly while the level of High density lipoprotein decreased in patients sera in comparison with healthy c
... Show MoreCurrent Thesis has aimed to identify : The Psychological barriers for university students , Differences in psychological barriers depending on the variable sex (Males – Females) , Adjustment to College life for university students, Differences in Adjustment to College at university life depending on the variable sex (Males – Females), and finally, The correlation between psychological barriers and Adjustment to College life. The researcher has prepared a sample consisted of (100) male and female students who were randomly selected from university students, The researcher has adopted a measure of (2002) to measure the psychological barriers, also the researcher adjustment scale with university life.
The results showed that universi