Preferred Language
Articles
/
3hdFWZABVTCNdQwCuIc4
Error Analysis of Stonex X300 Laser Scanner Close-range Measurements
...Show More Authors

This research reports an error analysis of close-range measurements from a Stonex X300 laser scanner in order to address range uncertainty behavior based on indoor experiments under fixed environmental conditions. The analysis includes procedures for estimating the precision and accuracy of the observational errors estimated from the Stonex X300 observations and conducted at intervals of 5 m within a range of 5 to 30 m. The laser 3D point cloud data of the individual scans is analyzed following a roughness analysis prior to the implementation of a Levenberg–Marquardt iterative closest points (LM-ICP) registration. This leads to identifying the level of roughness that was encountered due to the range-finder’s limitations in close-ranging as well as measurements that were obtained from extreme incident angle signals. The measurements were processed using a statistical outlier removal (SOR) filter to reduce the noise impact toward a smoother data set. The geometric differences and the RMSE values in the 3D coordinate directions were computed and analyzed, which showed the potential of the Stonex X300 measurements in close-ranging following a careful statistical analysis. It was found that the error differences in the vertical direction had a consistent behavior when the range increased, whereas the errors in the horizontal direction varied. However, it is more common to produce errors in the vertical direction as compared to the horizontal one.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Sep 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Analysis of Wave Propagation in Detection of Aorta Dieses Using Lumps Analysis
...Show More Authors

In this paper a theoretical attempt is made to determine whether changes in the aorta diameter at different location along the aorta can be detected by brachial artery measurement.  The aorta is divided into six main parts, each part with 4 lumps of 0.018m length. It is assumed that a desired section of the aorta has a radius change of 100,200, 500%. The results show that there is a significant change for part 2 (lumps 5-8) from the other parts. This indicates that the nearest position to the artery gives the significant change in the artery wave pressure while other parts of the aorta have a small effect.

View Publication Preview PDF
Publication Date
Tue Nov 28 2023
Journal Name
Journal Of Oral And Dental Research
Assessment of Some Mechanical Properties of CNC Laser Treated Ti13Zr13Nb Alloy
...Show More Authors

Background Alloys with the addition of zirconium and niobium eliminate the adverse effects of aluminum and vanadium on the nervous system, the possibility of metallosis and the initiation of diseases (including cancers or Alzheimer›s disease). In addition, they have better corrosion resistance, and a Young›s modulus value similar to longitudinal bone tissue. Therefore, only choosing appropriate materials does not guarantee proper functioning of the implants, the surfaces of the implants also have to be suitable to meet the requirements. The laser surface hardening process modifies the surface properties by imparting microstructural changes, whereas surface remelting induces changes in the surface topography, roughness, wettability and w

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 02 2024
Journal Name
Iraqi Journal Of Applied Physics
Evaluation of Corrosion Resistance of Laser-Treated and PEKK-Coated Titanium
...Show More Authors

This research focuses on improvement of the corrosion behaviour of commercial pure titanium (Ti) grade II when exposed to Hank’s solution through different surface treatments. The disc shape of titanium samples were constructed to be divided according to their surface treatment. The first experimental group the Ti sample was exposed to computer numerical control (CNC) fiber laser machine. Whereas, the other experimental group the Ti sample was only coated with Polyetherketon keton (PEKK) by using carbon dioxide (CO2) laser technique while the last experimental group the Ti sample was treated with CNC fiber laser followed by PEKK coating by using CO2 laser technique. All were compared with the untreated control group. The electrochemical a

... Show More
Preview PDF
Scopus (1)
Scopus
Publication Date
Sat Oct 01 2011
Journal Name
Iraqi Journal Of Physics
Nanocrystalline -Silicon Carbide Films Prepared by TEACO2 Laser
...Show More Authors

Thin films of microcrystalline and nanocrystalline -silicon carbide and silicon, where deposited on glass substrate with substrate temperature ranging from 350-400C, with deposition rate 0.5nm per pulse, by laser induced chemical vapor deposition. The deposition induced by TEACO2 laser. The reactant gases (SiH4 and C2H4) photo decompose throughout collision associated multiple photon dissociate. Such inhomogeneous film structure containing crystalline silicon, silicon carbide and amorphous silicon carbide matrix, give rise to a new type of material nanocrystalline silicon carbide in which the optical transmittance is governed by amorphous SiC phase while nanocrystalline grain are responsible for the conduction processes. This new m

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 07 2019
Journal Name
Iraqi Journal Of Laser
In Growing Toenail Treatment using Carbon Dioxide Laser
...Show More Authors

An ingrowing toenail is a common problem affecting mainly adolescents and young adults, with a male predominance of 3:1. The disorder generally occurs in big toes. It is painful and often chronic and it affects work and social activities. Most patients initially complain of pain and later discharge, infection and difficulty in walking occur. The Objectives: The purpose of the study was to evaluate the efficacy and safety of (10600nm) CO2 laser in the treatment of ingrowing toe nail. Patients, Materials & Methods: This study was done in laser medicine research clinics from July 2013 to the end of December 2013; 10 patients including 7(70%) males and 3 (30%) females with age ranging from 18 years to 70 years with mean age of 44 years o

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
Nanosecond laser pulses for aluminum and copper drilling
...Show More Authors

Nd:YAG laser pulses of 9 nanosecond pulse duration and operating wavelength at 1.06 μm, were utilized to drill high thermal conductivity and high reflectivity aluminum and copper foils. The results showed a dependence of drilled holes characteristics on laser power density and the number of laser pulses used. Drilled depth of 74 ϻm was obtained in aluminum at 11.036×108 W/cm2 of laser power density. Due to its higher melting point, copper required higher laser power density and/or larger number of laser pulses to melt, and a maximum depth of 25 μm was reached at 13.46×108 W/cm2 using single laser pulse.

View Publication Preview PDF
Crossref
Publication Date
Thu Nov 19 2020
Journal Name
Iop Conference Series: Materials Science And Engineering
Nickel Oxide Thin Films Grooved by Laser Processing
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Nov 01 2020
Journal Name
Iraqi Journal Of Laser
Urinary Tract Lithotripsy Using Holmium: YAG (2100nm) Laser
...Show More Authors

Background: Laser urinary stone lithotripsy is an established endourological modality. Ho:YAG(2100nm) laser have broadened  the indications for ureteroscopic stone managements  to include larger stone sizes throughout the whole urinary tract.

Purpose: To evaluate the effectiveness and safety of Holmium: YAG(2100nm) laser lithotripsy with a semirigid uretero scope for urinary stone calculi in a prospective cohort of 17 patients.

Patients and Methods: Holmium: YAG(2100nm) laser lithotripsy was performed with a semirigid ureteroscope in 17 patients from September 2016 to December  2016. Calculi were located in the lower ureter in 9 patients (52.9%), the midure

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 15 2022
Journal Name
Arab World English Journal
Genre-Based Analysis of Selected Political Debates: A Discourse Analysis Study
...Show More Authors

The researchers of the present study have conducted a genre analysis of two political debates between American presidential nominees in the 2016 and 2020 elections. The current study seeks to analyze the cognitive construction of political debates to evaluate the typical moves and strategies politicians use to express their communicative intentions and to reveal the language manifestations of those moves and strategies. To achieve the study’s aims, the researchers adopt Bhatia’s (1993) framework of cognitive construction supported by van Emeren’s (2010) pragma-dialectic framework. The study demonstrates that both presidents adhere to this genre structuring to further their political agendas. For a positive and promising image

... Show More
View Publication Preview PDF
Clarivate Crossref
Publication Date
Sun Jan 01 2023
Journal Name
International Journal Of Humanities And Social Sciences/ Rimak
AN EMPIRICAL ANALYSIS OF EDUCATIONAL RESEARCH BASED ON CRITICAL DISCOURSE ANALYSIS
...Show More Authors

APDBN Rashid, International Journal of Humanities and Social Sciences/ RIMAK, 2023

View Publication