The calculation of the oil density is more complex due to a wide range of pressuresand temperatures, which are always determined by specific conditions, pressure andtemperature. Therefore, the calculations that depend on oil components are moreaccurate and easier in finding such kind of requirements. The analyses of twenty liveoil samples are utilized. The three parameters Peng Robinson equation of state istuned to get match between measured and calculated oil viscosity. The Lohrenz-Bray-Clark (LBC) viscosity calculation technique is adopted to calculate the viscosity of oilfrom the given composition, pressure and temperature for 20 samples. The tunedequation of state is used to generate oil viscosity values for a range of temperature andpressure extends from the reservoir to surface conditions.The generated viscosity data is utilized in the neural network tool (NN) to get fittingmodel correlates the viscosity of oil with composition, pressure and temperature. Theresulted error and the correlation coefficient of the model constructed are close to 0and 1 respectively. The NN model is also tested with data that are not used in set upthe model. The results proved the validity of the model. Moreover, the model’soutcomes demonstrate its superiority to selected empirical correlations.
The research discusses two variables are important, orientation marketing and quality of service, and that the purpose of the research is to see whether the telecom companies applied orientation marketing or not and to what extent is keen to apply it to suit the Iraqi environment as it has been applied research in kork Telecom company and Asia Cell Telecom are sectors service job in the business sector in Iraq, The information was obtained through the design of the questionnaire compatible runway Likert, and distribution (92) questionnaire, which (50) for the company Korek Telecom and (42) of the Asia-Cell, research population sample included a number of staff in the departments and units in the two companies, it has been support
... Show MoreThe objectives of this study revolve around identifying the extent of funding impact on the future of the printed Iraqi press, and whether it threatens their chances of survival, stating the extent of technological development on the income of the printed newspaper, and identifying the causes of the financial crisis on the newspaper.
This research is classified as descriptive research, and the researcher used the survey method, and adopted the questionnaire of the views of the contactors, in five Iraqi newspapers (morning - extent - time - the way of the people - the call).
The research community included (68) respondents, whereby the comprehensive inventory method was used to define the research community, and the researcher used
This research amid to measure the impact of organizational flexibility (structural flexibility, operational flexibility, and strategic flexibility) in achieving organizational prosperity and its dimensions (strategic agility, intellectual capital, innovation and sustainable competitive advantage) in a number of Iraqi cellular communications companies. The research adopted descriptive analytical approach. A sample of (85) persons from the research community was selected, which included (Department managers, Directors administrative units, Communication engineers), to answer the questionnaire prepared for this purpose. And to analyze data and derive results. Statist
... Show Morein this paper we adopted ways for detecting edges locally classical prewitt operators and modification it are adopted to perform the edge detection and comparing then with sobel opreators the study shows that using a prewitt opreators
A LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.