Titanium alloy (Ti-6Al-4V) samples were nitrided in low pressure (1.3, 3 mbar) dc-glow discharge plasmas of nitrogen. The treating time was 5, 10 and 15 hour and the temperatures range of the samples during the nitriding process was close to 800oC. The obtained microstructures of the nitride layers were studied by x-ray diffraction and optical microscopy. The ε –Ti2N, ζ-Ti3N3-x and η-Ti3N2-x.phases were formed and addition to the solid solution of nitrogen in titanium, α (Ti,N). Micro hardness measurements exhibit an increment for the Ti-alloy specimens which nitrided at 800oC for 10 and 15h.Corrosion measurements were obtained for the Ti-6Al-4V alloy in Ringer solution after plasma nitriding. The clear improving in the corrosion r
... Show MoreThe possibility of using the magnetic field technique in prevention of forming scales in heat exchangers pipes using
hard water in heat transfer processes, also the studying the effective and controllable parameters on the mechanism of
scale formation.
The new designed heat exchanger experimental system was used after carrying out the basic process designs of the
system. This system was used to study the effect of the temperature (40-90 °C) and water flow rate (0.6-1.2 L/min) on
the total hardness with time as a function of precipitation of hardness salts from water and scale formation.
Different magnetic field designs in the heat exchanger experimental system were used to study the effect of magnetic
field design a
In this study, the hydromorphodynamic simulation of a stretch of the Euphrates River was conducted. The stretch of the Euphrates River extended from Haditha dam to the city of Heet in Al-Anbar Governorate and it is estimated to be 124.4 km. Samples were taken from 3 sites along the banks of the river stretch using sampling equipment. The samples were taken to the laboratory for grain size analysis where the median size (D50) and sediment load were determined. The hydromorphodynamic simulation was conducted using the NACY 2DH solver of the iRIC model. The model was calibration using the Manning roughness, sediment load, and median particle size and the validation process showed that the error between th
... Show MoreOwing to high antibacterial resistance of Pseudomonas aeruginosa, it could be considered as the main reason behind the nosocomial infections. P. aeruginosa has a well-known biofilm forming ability. The expression of polysaccharide encoding locus (pelA gene) by P. aeruginosa is essential for this ability. The purpose of the current research was to determine the biofilm formation in P. aeruginosa isolated from clinical samples and to evaluate the role of the selected PelA gene in biofilm formation using PCR method in Iraqi patients. Results revealed that 24 (96%) isolates were found to have the ability to form biofilm that was remarkably related to gentamicin resistance. Moreover, the pelA gene was found in all biofilm-producers. In c
... Show MoreFive
a porentioncsisteve has been carried out of the corrosion behavior of inconel(600) in chloride ions (Cl) over the tempreatures 293 over the temperatures 308K in both the dcacrated and the alloy
In this work, radius of shock wave of plasma plume (R) and speed of plasma (U) have been calculated theoretically using Matlab program.
Objective(s): To assess nurses' practices for neurological unconscious patients in intensive care units.
Methodology: A descriptive study was conducted that included (50) nurse who are working in intensive care
units in hospitals and departments of the nervous system in (4) hospitals (neuroscience hospital, teaching
neurosurgical hospital, surgical specialist hospital, and sheck zaied hospital) in Baghdad city from March, 30th
,
2009 to July, 30th 2009 for the purpose of assessing their skills towards unconscious patients. A purposive "nonprobability
sample" was selected that consisted of (50) nurse who are working in intensive care units. A
questionnaire format and observational checklist were used which consist of
As one type of resistance furnace, the electrical tube furnace (ETF) typically experiences input noise, measurement noise, system uncertainties, unmodeled dynamics and external disturbances, which significantly degrade its temperature control performance. To provide precise, and robust temperature tracking performance for the ETF, a robust composite control (RCC) method is proposed in this paper. The overall RCC method consists of four elements: First, the mathematical model of the ETF system is deduced, then a state feedback control (SFC) is constructed. Third, a novel disturbance observer (DO) is designed to estimate the lumped disturbance with one observer parameter. Moreover, the stability of the closed loop system including controller
... Show More