Preferred Language
Articles
/
2xaeS4cBVTCNdQwC2UK_
Mathematical Model for BOD in Waste Water Discharges from Al Dora Refinery in Baghdad
...Show More Authors

This research consists of two parts, the first part concern with analyzing the collected data of BOD and COD values in discharge waste water from Al-Dora refinery during 2010 to find the relationship between these two variables The results indicates that there is a high correlation between BOD and COD when using a natural logarithm model (0.86 ln(COD)) with correlation coefficient of 0.98. This relationship is useful in predicting the BOD value using the COD value. The second part includes analyzing collected data from the same site in order to find a relationsip between BOD and other parameters COD, Phenol(phe), Temperature(T), Oil, Sulphat(SO4),pH and Total dissolved solids( TDS) discharged from the refinery. The results indicated that the best mathematical model is BOD= 0.786 (ln(COD))^2- 3.077E83/Exp(10T) + 1.76E+48/Exp(0.1TDS)- 5.6507/Exp(100Phe) With correlation coefficient of 0.873. The presented research demonstrates many conclusions regarding the relation between BOD and other pollutions, it is clear that the relation between BOD and COD is a direct relation, while it’s a reverse relation with other pollutions and it’s also clear that a linear model can be used to represent the relation between BOD and COD for a value of COD approximately less than (50 mg/L).

Publication Date
Sun Dec 06 2009
Journal Name
Baghdad Science Journal
Study of Molecular Interactions of Water- Soluble Polymer at Several Temperatures in Solution
...Show More Authors

Molecular interactions between 2-isopropenylnaphthalene-methacrylic acid (IPNMA) block copolymer( as a model for water- soluble polymer) and methanol at several temperatures were studied using fluorescence techniques , Fluorescence spectrum for (IPNMA) exhibits two emission bands at around 342 nm and 387 nm corresponding to the monomer and the excimer bands , respectively .The fluorescence spectra of dilute solution of (IPNMA) in methanol were recorded in temperature range of 8- 45?C . Plot of the excimer to monomer intensity ratio Ie/Im versus temperature was obtained, which shows double lines with positive slopes crossing at 25?C , the increasing of slope value above this temperature is s

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 30 2020
Journal Name
Journal Of Engineering
Advanced Oxidation of Antibiotics Polluted Water Using Titanium Dioxide in Solar Photocatalysis Reactor
...Show More Authors

The aim of this study was to investigate antibiotic amoxicillin removal from syn­thetic pharmaceutical wastewater. Titanium dioxide (TiO2) was used in photocatalysis treatment method under natural solar irradiation in a tubular reactor. The photocatalytic removal efficiency was evaluated by the reduction in amoxicillin concentration. The effects of antibiotics concentration, TiO2 dose, irradiation time and the effect of pH were studied. The optimum conditions were found to be irradiation time 5 hr, catalyst dosage 0.6 g/L, flow rate 1 L/min and pH 5. The photocatalytic treatment was able to destruct the amoxicillin in 5 hr and induced an amoxicillin reduction of about 10% with 141.8 kJ/L accumulate

... Show More
View Publication Preview PDF
Crossref (13)
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Al-khwarizmi Engineering Journal
Theoretical Prediction of Optimum Chilled Water Distribution Configuration in Air Conditioning Terminal Unit
...Show More Authors

 The distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Mar 13 2011
Journal Name
Baghdad Science Journal
Use of Coliphages as an indicators of enteroviruses and faecal pollution in Water
...Show More Authors

In spite of increasing clinical cases which caused by enteroviruses transferred by water and no documents about entericviruses in the Iraqi water standards. The use of coliphages as an indicator of enteroviruses and fecal pollution were suggested two procedures were applied . The first is Two-Step Enrichment Method and the second is Single Agar Layer Method. Both methods gives good results in Identification of coliphages through testing fifty different water samples (Tap water, Surface water and Bottled water) the study shows the presence of coliphages in fourteen samples.

View Publication Preview PDF
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Al-khwarizmi Engineering Journal
The Study of Ability of Local Ninivite Rocks in Purification of Drinking Water
...Show More Authors

This study is conducted to verify the efficienecy of local Ninivite rock when used in the treatment of drinking water in plants operating currently in the country in order to develop the situation of these stations to cope with the increase in population. Also, this will limit the pollutian which are increasing in the country's rivers.

(Euphrates and Tigris). These rivers are the sources to feed all water treatment plants in the country. The idea is the develop or the modify these stations by replacing part of top layer of sand filters used in these stations with Ninivite rock to operate as filters composed of two medium. The efficiency of this rock is compared with other materials used successfully worldwide in this area, such a

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
partial molal volume and viscosity study of vitamin B1 and B3 in water
...Show More Authors

the study covered theoretical concering parial molal volume the applicability of jones-dole equation

View Publication Preview PDF
Publication Date
Mon Dec 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Corrosion Inhibition of Galvanic Couple Copper Alloy/Mild Steel in Cooling Water System
...Show More Authors

The driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Absorption of NO2 into Water and Nitric Acid Solutions in a Fixed Column
...Show More Authors

View Publication Preview PDF
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Concrete strength development by using magnetized water in normal and self-compacted concrete
...Show More Authors
Abstract<p>The main objective of this work was to adopt an environmentally friendly technology with enhanced results. The technology of magnetic water (MW) treatment system can be used in concrete mixture production instead of potable water (PW) to improve both workability and strength. Two types of concrete were adopted: normal concreter production with two grades 25 and 35 MPa and the self-compacted concrete (SCC) with 35 MPa grade. The concrete mixes containing MW instead of PW results showed that, for 25 MPa grade, an improvement in a compressive strength of 15.1, 14.8, and 10.2% was achieved for 7, 28, and 90 days, respectively. For 35 MPa grade, an improvement of 13.6, 11.5, and </p> ... Show More
Crossref (6)
Crossref