Preferred Language
Articles
/
2BggWJUBVTCNdQwCpCzU
Effect of Incorporating Chitosan to Resin Modified Glass Ionomer Cement on Shear Bond Strength to Dentin (An In vitro Comparative Study)
...Show More Authors
A<sc>bstract</sc> <sec> <title>Aim:

Resin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This in vitro study evaluates the impact of chitosan, a biopolymer that is, both biomaterial and biocompatible, on the strength of dentin bonding and compares it with ACTIVA Bio-ACTIVE Restorative. The present study was aimed to assess the impact of including chitosan into Fuji II on the shear bond strength between. the restoration material and tooth dentin, in contrast to Bioactiva in permanent teeth.

Materials and Methods:

A total of 30 premolar teeth were recently extracted. The study involved three distinct sample groups. Group 1 (10 teeth) is the negative control (Fuji II), Group 2 (10 teeth) is the positive control (ACTIVA Bio-ACTIVE Restorative), and Group 3 (10 teeth) is treated with a mixture of Chitosan and Fuji II (CH-Fuji II). Each tooth’s buccal and palatal cusps were eliminated to achieve a horizontal surface. Using a periodontal probe, 1.5 mm from the mesial pit to the mesial marginal ridge were removed. Restoration was implemented in all groups following manufacturer directions. Thermocycling the teeth by immersing them in a water bath with temperatures ranging from 5°C to 55°C (± 1–2°C) for 30 s (500 cycles). Each sample was attached to the universal testing machine’s jig at a cross-head speed of 1 mm/min. Shear force was used until breakage, and the bond’s adhesive strength was then calculated. Statistical analysis using ANOVA with Dunnett’s T3 post hoc test. Results were significant at P < 0.05.

Results:

Statistically significant difference was present between Chitosan and Fuji II and between Chitosan and Activa by reducing the shear bond strength.

Conclusions:

Addition of chitosan to Fuji II had a negative effect on the shear bond with a significant difference while Activa and Fuji II exhibited favorable shear bond strength.

Scopus Clarivate Crossref
View Publication
Publication Date
Tue Nov 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
Push-out bond strength of different root canal obturation materials
...Show More Authors

Background: The aim of this study was to evaluate the push-out bond strength of four different obturation materials to intraradicular dentin and to determine the failure mode. Materials and method: forty straight palatal roots of the maxillary first molars teeth were used in this study, the roots were instrumented using crown down technique and rotary EndoSequence system, the roots were randomly divided into four groups according to the materials used for obturation (n=10).Group (1): AH Plus sealer and gutta-percha. Group (2): Activ GP glass ionomer sealer and Activ GP gutta-percha (Activ GP system). Group (3): Bioceramic sealer and Bioceramic gutta-percha. Group (4): GuttaFlow2 sealer and gutta-percha. For all groups single cone obturatio

... Show More
View Publication Preview PDF
Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
A comparative Study to calculate the Runs Property in the encryption systems
...Show More Authors

Cryptographic applications demand much more of a pseudo-random-sequence
generator than do most other applications. Cryptographic randomness does not mean just
statistical randomness, although that is part of it. For a sequence to be cryptographically
secure pseudo-random, it must be unpredictable.
The random sequences should satisfy the basic randomness postulates; one of them is
the run postulate (sequences of the same bit). These sequences should have about the same
number of ones and zeros, about half the runs should be of length one, one quarter of length
two, one eighth of length three, and so on.The distribution of run lengths for zeros and ones
should be the same. These properties can be measured determinis

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 01 2020
Journal Name
Iraqi Journal Of Physics
Studying the Impact Strength of Layered Denture Base Resin
...Show More Authors

This paper displays the effect of uncoated and coated chopped carbon fibers with alumina Al2O3 or Tri calcium phosphate (TCP) on the impact strength of acrylic poly methyl methacrylate (PMMA) denture base resin. To improve bonding between carbon fibers and coating materials powders, the surface of carbon fibers has been treated with Para amino benzoic acid (C9H10N2O3) and poly vinyl alcohol (PVA) was also used. The morphology of the coating layers has been examined by field emission scanning electron microscope (FE-SEM). From the results, PMMA reinforced with uncoated chopped carbon fiber has high impact strength value but still have bad aesthetic.  Samples prepared b

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Mar 30 2022
Journal Name
Gsc Biological And Pharmaceutical Sciences
Using the silicon (luminal cast plastination technique) for the lower respiratory tract in sheep as an alternative to cement
...Show More Authors

The lower respiratory tract of sheep was studied to determine the torsion and branching of the bronchial tree. The respiratory system of ruminants and all living organisms is one of the most important organs in the body that controls the amount of gas exchange between the heart and lungs through the airways, it is clear that in sheep it consists of a narrow bronchial tube that reaches the extent of lung tissue repercussions. He used silicon, water, acid, and at room temperature, and the substance was injected with an injection gun through the trachea and was pushed gently to spread and distribute in all parts of the lungs with moderate manual pressure. The results showed that the mold shape in the lung and the bronchial branches of

... Show More
View Publication
Crossref
Publication Date
Tue Nov 11 2025
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of different finishing and polishing systems on surface roughness of new low polymerized composite materials (An in vitro study)
...Show More Authors

Background: Prophylaxis methods are used to mechanically remove plaque and stain from tooth surfaces; such methods give rise to loss of superficial structure and roughen the surface of composites as a result of their abrasive action. This study was done to assess the effect of three polishing systems on surface texture of new anterior composites after storage in artificial saliva. Materials and methods: A total of 40 Giomer and Tetric®N-Ceram composite discs of 12 mm internal diameter and 3mm height were prepared using a specially designed cylindrical mold and were stored in artificial saliva for one month and then samples were divided into four groups according to surface treatment: Group A (control group):10 specimens received no surfa

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Different Fluoride Agents on the Load Deflection Characteristics of Heat Activated Nickel Titanium Arch Wires (An in Vitro Study)
...Show More Authors

ABSTRACT Background:Hydrogen absorption and related degradation in the mechanical properties of Ni-Ti based orthodontic wires has been demonstrated following exposure to fluoride prophylactic agents. This study was designed to investigate the effects of three fluoride containing agents on the load deflection characteristics of heat activated nickel titanium arch wires during unloading phase. Material and method: Eighty specimens of heat activated nickel titanium arch wires were obtained from Ortho Technology Company, half of which had a 0.016 inch round and 0.019x0.025 rectangular. Ten specimens from both wire size were immersed in one of the tested fluoride prophylactic agents (neutral sodium fluoride gel, stannous fluoride gel or phos-flu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
STUDY OF TEMPERATURE EFFECT ON THE HARDNESS FOR EPOXY RESIN AND UNSATURATED POLYESTER
...Show More Authors

This search aim to measure Hardness for Epoxy resin and for unsaturated Polyester resin as base materials for composite Hybrid and the materials used is Hybrid fiber Carbon-Kevlar. The Hand Lay-up method was used to manufacture plates of Epoxy resin (EP) and unsaturated Polyester EP,UPE backed by Hybrid fiber (Carbon-Kevlar) and with small volume fraction 5,10 and 15 for every there are Layer of fibers (1,2 and 3). The hardness test was count for material EP, UPE resin and there composites and that we notice that the Hardness (HB) decreased with increase of temperatures.

View Publication Preview PDF
Crossref
Publication Date
Thu May 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Effect of Stiffeners on Shear Lag in Steel Box Girders
...Show More Authors

This paper studies the effects of stiffeners on shear lag in steel box girders with stiffened flanges. A three-dimensional linear finite element analysis using STAAD.Pro V8i program has been employed to evaluate and determine the actual top flange stress distribution and effective width in steel box girders. The steel plates of the flanges and webs have been modeled by four-node isoparametric shell elements, while the stiffeners have been modeled as beam elements. Different numbers (4, 8, and 15) for the steel stiffeners have been used in this study to establish their effects on the shear lag and longitudinal stresses in the flange. Using stiffeners reduced the magnitude of the top flange longitudinal stresses about 40%, but did

... Show More
View Publication Preview PDF
Publication Date
Tue Apr 26 2022
Journal Name
Journal Of Contemporary Medical Sciences
Doxorubicin Immobilization on chitosan-modified silver Nanoparticles as a drug delivery method for effective anticancer treatment
...Show More Authors

Objective: The goal of this research is to load Doxorubicin (DOX) on silver nanoparticles coupled with folic acid and test their anticancer properties against breast cancer. Methods: Chitosan-Capped silver nanoparticles (CS-AgNPs) were manufactured and loaded with folic acid as well as an anticancer drug, Doxorubicin, to form CS-AgNPs-DOX-FA conjugate. AFM, FTIR, and SEM techniques were used to characterize the samples. The produced multifunctional nano-formulation served as an intrinsic drug delivery system, allowing for effective loading and targeting of chemotherapeutics on the Breast cancer (AMJ 13) cell line. Flowcytometry was used to assess therapy efficacy by measuring apoptotic induction.  Results: DOX and CS-Ag

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Jul 20 2023
Journal Name
Polymers In Medicine
Effect of subinhibitory doses of rifaximin on in vitro Pseudomonas aeruginosa adherence and biofilm formation to biotic and abiotic surface models
...Show More Authors

View Publication Preview PDF
Scopus (4)
Scopus Crossref