Preferred Language
Articles
/
24YUsoYBIXToZYAL_rAo
Influence of water-absorbent polymer balls on the structural performance of reinforced concrete beam: An experimental investigation
...Show More Authors
Abstract<p>This research investigated the influence of water-absorbent polymer balls (WAPB) on reinforced concrete beams’ structural behavior experimentally. Four self-compacted reinforced concrete beams of identical geometric layouts 150 mm × 200 mm × 1,500 mm, reinforcement details, and compressive strength <inline-formula> <alternatives> <inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/j_jmbm-2022-0024_eq_001.png"></inline-graphic> <math xmlns:m="http://www.w3.org/1998/Math/MathML"> <msubsup> <mrow> <mi>f</mi> </mrow> <mrow> <mtext>c</mtext> </mrow> <mrow> <mo accent="true">′</mo> </mrow> </msubsup> </math> <tex-math>{f}_{\text{c}}^{^{\prime} }</tex-math> </alternatives> </inline-formula> ≈ 50 MPa were castellated. Each beam contained a volume percentage of WAPB that differed from the others, and the considered percentages were <italic>V</italic> <sub>b</sub> = 0, 1, 2, and 3%. A static test under two-point loads was adopted to evaluate the structural behavior of the tested beams. The results indicated that the maximum load capacity of the tested beams was increased by 2.0, 3.0, and 7.14% for the volume percentages of 1, 2, and 3%, respectively, as compared to the reference beam (<italic>V</italic> <sub>b</sub> = 0%). It was also observed that the impact of <italic>V</italic> <sub>b</sub> = 3% was higher than that of the other percentages. For all the tested beams, the mode of failure was a flexural failure that is compatible with the considered preliminary design. The results showed that increasing the percentage of polymer to 3% had a significant effect on the deflection, as the deflection was directly proportioned to the percentage of WAPB.</p>
Crossref
Publication Date
Tue Jul 27 2021
Journal Name
Journal Of Craniofacial Surgery
Morphometric Analysis of the Mental Foramen Variation in an Iraqi Population by Using Cone-Beam Computed Tomography
...Show More Authors

View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Jun 01 2019
Journal Name
Prensa Medica Argentina
The effect of niclosamide in acetic-acid induce colitis: An experimental study
...Show More Authors

Scopus (31)
Scopus
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
The Influence of Temperature and Flow Velocity on the Corrosion Inhibition of Low Carbon Tubes in Recirculating Water System by a Dicomponent Inhibitor Blend
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Investigation hydraulic performance of splash fills packing in cooling tower
...Show More Authors

Heat is one of the most energy forms emitted to atmosphere by industrial processes. Water is considered to be the best material to reduce heat energy since its available in nature in abundance and has the ability to absorb heat efficiently. Cooling towers are ideal alternatives to re-cool hot water instead of throwing it especially in places that lack natural water resources or when there are environmental precautions because water with high temperature would be harmful to the ecosystem when it recycled to natural resources such as rivers and lakes. Also, cooling towers considered economically feasible when using west water. This paper interests with hydraulic characteristics of a counter flow wet cooling tower which was investigated experi

... Show More
View Publication
Scopus (6)
Crossref (3)
Scopus Crossref
Publication Date
Fri Sep 01 2023
Journal Name
Journal Of Engineering
The Effect of Cohesive Debonding Elimination on Enhancing the Flexural Performance of Damaged Unbonded Prestressed Concrete Girders Strengthened Using NSM CFRP
...Show More Authors

This manuscript studied the effect of U-CFRP wrapped sheet anchorage on the flexural performance of unbonded post-tensioned PC members subjected to partial strand damage and strengthened using CFRP Near-Surface Mounting techniques. The program includes six girders as a control girder, a girder with strand damage of 14.2%, and four girders strengthened by CFRP laminates using the NSM technique with and without U-CFRP wrapped sheet anchorages. The testing results show that the strand damage of 14.2% has reduced the flexural strength of the girder by 5.71%. The NSM-CFRP laminate has a significant effect on flexural strength by 17.4%. On the other hand, the application of end U-CFRP wrapped sheet anchorages improves flexural

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 01 2025
Journal Name
Results In Engineering
Experimental investigation of a solar HDH desalination unit with Pottery tubes in babylon province
...Show More Authors

The Humidification-Dehumidification (HDH) desalination technique offers a viable solution for providing freshwater to populations in water-scarce, remote areas. This study experimentally investigates a novel humidifying method by cross airflow over water-wetted pottery tubes, which function as a humidifier, incorporating a thermoelectric cooler to condense water vapor for freshwater production. To optimize freshwater production and thermal efficiency, meticulous design of these components and appropriate operational parameters are selected. Experiments were performed in three environments with differing temperatures and relative humidity levels, while air velocity varied from 1.02 to 1.89 m/s, and thermoelectric cooler voltage ranged from 6

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Thu Dec 01 2016
Journal Name
Journal Of Engineering
Experimental Investigation of Natural Convection into a Horizontal Annular Tube with Porous Medium Effects
...Show More Authors

In this work, an experimental investigation has been done for heat transfer by natural-convection through a horizontal concentric annulus with porous media effects. The porous structure in gap spacing consists of a glass balls and replaced by plastic (PVC) balls with different sizes. The outer surface of outer tube is isothermally cooled while the outer surface of inner tube is heated with constant heat flux condition. The inner tube is heated with different supplied electrical power levels. Four different radius ratios of annulus are used. The effects of porous media material, particles size and annulus radius ratio on heat dissipation in terms of average Nusselt number have been analyzed.

... Show More
View Publication Preview PDF
Publication Date
Mon Jul 31 2017
Journal Name
Journal Of Engineering
Experimental and Numerical Investigation of Hyper Composite Plate Structure Under Thermal and Mechanical Loadings
...Show More Authors

View Publication Preview PDF
Publication Date
Thu Apr 01 2021
Journal Name
Journal Of Bridge Engineering
Experimental Investigation of Curved-Soffit RC Bridge Girders Strengthened in Flexure Using CFRP Composites
...Show More Authors

View Publication
Crossref (13)
Crossref
Publication Date
Sun Mar 05 2017
Journal Name
Baghdad Science Journal
Studying the effective of conductor polymer substrate on the electrical properties of semiconductors
...Show More Authors

This research includes depositionof thin film of semiconductor, CdSe by vaccum evaporation on conductor polymers substrate to the poly aniline where, the polymer deposition on the glass substrats by polymerization oxidation tests polymeric films and studied the structural and optical properties through it,s IR and UV-Vis , XRD addition to thin film CdSe, on of the glass substrate and on the substrate of polymer poly-aniline and when XRD tests was observed to improve the properties of synthetic tests as well as the semiconductor Hall effect proved to improve the electrical properties significantly

View Publication Preview PDF
Scopus (2)
Scopus Crossref