This work introduces a new electrode geometry for making holes with high aspect ratios on AISI 304 using an electrical discharge drilling (EDD) process. In addition to commercially available cylindrical hollow electrodes, an elliptical electrode geometry has been designed, manufactured, and implemented. The principal aim was to improve the removal of debris formed during the erosion process that adversely affects the aspect ratio, dimensional accuracy, and surface integrity. The results were compared and discussed to evaluate the effectiveness of electrode geometry on the machining performance of EDD process with respect to the material removal rate (MRR,) the electrode wear rate (EWR), and the tool wear ratio (TWR). Dimensional features and surface characteristics of the drilled holes were also evaluated in aspects of overcut (OC), aspect ratio (AR), and surface roughness (SR). The experimental results revealed that an elliptical electrode is preferable for producing holes with good dimensional accuracy and improved surface quality. In addition, 3D models of flow field with liquid, gas, and solid phases are proposed for analyses of the interelectrode gap within the machining zone. Based on the results obtained from models, the elliptical electrode also exhibited good flushing capability for effective debris removal.
MRY *Khalid Sh. Sharhan, *Naseer Shukur Hussein, INTERNATIONAL JOURNAL OF DEVELOPMENT IN SOCIAL SCIENCE AND HUMANITIES, 2021
Background: Radial neck fractures in children account for 5 to 10% of all elbow fractures in children. They are extra-articular fractures of the radius proximal to the bicipital tuberosity. The physis is typically involved as a Salter-Harris I or II pattern. Alternatively, the fracture sometimes is extraphyseal, through the metaphysis. In children there is considerable potential for remodeling after these fractures. Up to 30° of radial head tilt and up to 3 mm of transverse displacement are acceptable. Many modalities of treatment are available regarding Surgical &Non-Surgical treatments. Objectives: To evaluate the functional outcome after surgical percutaneous joystick reduction therapy of severely angulated radial neck fracture i
... Show MoreHere, a high sensitive method for biomarker identification according to nanostructure, using enzyme-linked immunosorbent assays (ELISAs), called Nano-ELISA, was presented. Different shapes of gold nanostructures (star and sphere; GNSs and GNPs) with a particle size of 40 nm for sphere particles were altered with a monoclonal antibody (Ab) as a detector Ab. To amplify the optical signal, gold nanostructures were employed as carriers of the signaling specific antibody against insulin growth factor binding protein- 3 (IGFBP-3). The substrate was catalytically oxidized by the Horseradish Peroxidase (HRP) conjugated gold nanostructure, and HRP also enhanced the optical signals, reflecting the amount of the targeting IGFBP-3. In comparison to t
... Show MoreAbstract: Aluminum alloys grade 6061-T6 are characterized by their excellent properties and processing characteristics which make them ideal for varieties of industrial applications under cyclic loading, aluminum alloys show less fatigue life than steel alloys of similar strength. In the current study, a nanosecond fiber laser of maximum pulse energy up to 9.9 mJ was used to apply laser shock peening process (LSP) on aluminum thin sheets to introduce residual stresses in order to enhance fatigue life under cyclic loading Box-Behnken design (BBD) based on the design of experiments (DOE) was employed in this study for experimental design data analysis, model building and optimization The effect of working parameters spot size (ω), scannin
... Show MoreInternal control is system,defined and implemented under its responsibility , which aims to ensure that; laws and regulations are complied with; the instructions and directional guidelines fixed by Executive Management or the Management Borad are applied; the company internal processes are functioning correctlly , particularly those implicating the security of its assets; Financial Information is reliable; and generally contributes to the control over its activities , to the efficiency of its operation and to the efficient utilisation of its Resources. By helping to anticipate and control the risks involved in not meeting the objectives the company has set for itself, the internal control system plays akey role in conducting & monito
... Show MoreBackground: This in vitro study compares a novel calcium-phosphate etchant paste to conventional 37% phosphoric acid gel for bonding metal and ceramic brackets by evaluating the shear bond strength, remnant adhesive and enamel damage following water storage, acid challenge and fatigue loading. Material and Methods: Metal and ceramic brackets were bonded to 240 extracted human premolars using two enamel conditioning protocols: conventional 37% phosphoric acid (PA) gel (control), and an acidic calcium-phosphate (CaP) paste. The CaP paste was prepared from β-tricalcium phosphate and monocalcium phosphate monohydrate powders mixed with 37% phosphoric acid solution, and the resulting phase was confirmed using FTIR. The bonded premolars were exp
... Show MoreHR Al-Hamamy, KE Sharquie, AA Noaimi, WN Hussein, Our Dermatology Online, 2014 - Cited by 6
The variety of ideas and freedom of expression among the authors who are looking for everything new that serves the goals of musical and aesthetic expression, which calls for the use of traditional musical instruments with the great composition of musical instruments known as the orchestra represents a great challenge in several aspects. The incompetence of some of these instruments or limited capabilities or its costly method of performance sometimes forbids its use permanently in this great composition. It was necessary to have some problems facing the composer and the player on the one hand and the recipient on the other hand, who must be looking for perfection. Among those instruments that are used regularly in the works of the orche
... Show MoreObjective: To compare two positioning approaches in the surgical treatment of unstable intertrochanteric femoral fractures fixed by proximal femoral nailing, the supine versus lateral decubitus position Methodology: This randomized prospective comparative study on 26 patients with unstable intertrochanteric fractures was carried out from January 2020 and June 2022. We randomly divided patients into two groups: group A (13 patients) were operated using the traction table in the supine position for implant insertion, and group B (13 patients) were operated using the lateral decubitus position. We compared both groups regarding the setup time, operative time, tip-to-apex distance, collodiaphyseal angle, time for fluoroscopic time expo
... Show More