Preferred Language
Articles
/
1uY8fZwBmraWrQ4dA0p0
Natural deep eutectic solvent integrated with bulk liquid membrane system for salicylic acid removal from wastewater
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Mon Jun 01 2020
Journal Name
Heliyon
Electrocoagulation treatment of high saline oily wastewater: evaluation and optimization
...Show More Authors

The present work provides to treat real oily saline wastewater released from drilling oil sites by the use of electrocoagulation technique. Aluminum tubes were utilized as electrodes in a concentric manner to minimize the concentrations of 113400 mg TDS/L, 65623 mg TSS/L, and the ions of 477 mg HCO3/L, 102000 mg Cl/L and 5600 mg Ca/L presented in real oily wastewater under the effect of the operational parameters (the applied current and reaction time) by making use of the central composite rotatable design. The final concentrations of TDS, TSS, HCO3, Cl, and Ca that obtained were 93555 ppm (17.50%), 11011 ppm (83.22%), 189ppm (60.38%), 80000ppm (22%), and 4200 ppm (25%), respectively, under the optimum values of the operational parameters

... Show More
View Publication
Scopus (84)
Crossref (67)
Scopus Clarivate Crossref
Publication Date
Tue Jun 20 2023
Journal Name
Baghdad Science Journal
Treatment of Dairy Wastewater by Electrocoagulation using Iron Filings Electrodes
...Show More Authors

This study investigated the treatment of dairy wastewater using the electrocoagulation method with iron filings as electrodes. The study dealt with real samples collected from local factory for dairy products in Baghdad. The Response Surface Methodology (RSM) was used to optimize five experimental variables at six levels for each variable, for estimating chemical oxygen demand (COD) removal efficiency. These variables were the distance between electrodes, detention time, dosage of NaCl as electrolyte, initial COD concentration, and current density. RSM was investigated the direct and complex interaction effects between parameters to estimate the optimum values. The respective optimum value was 1 cm for the distance between electrodes, (6

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Mon Aug 30 2021
Journal Name
Al-kindy College Medical Journal
Practice and Opinion of Doctors in Primary Health Care Centers Toward Referral System: Samples from Nine Governorates in Iraq
...Show More Authors

Background: Most primary Health Care Centers (PHCCs) in Iraq have a referral system records; however, this mechanism does not function well because of the lack of other requirements for an efficient referral system.

Objective: To assess the practice & opinion of doctors in PHCs toward the referral system, and to determine the doctors in PHC's commitment to referral system instructions and guidelines.

Subjects and methods: A cross-sectional study with analytic elements was conducted in nine health directorates in Iraq, from the 1st October 2018 – 30th June 2019.One PHC was selected randomly form each sector in every governorate, A questionnaire was used to collect the required information.

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
5'-nucleoridase activity in sera from iraq children with leukemia
...Show More Authors

Enzyme activity were studied in the sera of children with leukemia than healthy children, where 31 cases were studied, including 21 cases of patients with acute lymphatic leukemia

View Publication Preview PDF
Publication Date
Thu Feb 01 2018
Journal Name
Journal Of Computational And Theoretical Nanoscience
Development of Wireless Controlling and Monitoring System for Robotic Hand Using Zigbee Protocol
...Show More Authors

Nowadays, the robotic arm is fast becoming the most popular robotic form used in the industry among others. Therefore, the issues regarding remote monitoring and controlling system are very important, which measures different environmental parameters at a distance away from the room and sets various condition for a desired environment through a wireless communication system operated from a central room. Thus, it is crucial to create a programming system which can control the movement of each part of the industrial robot in order to ensure it functions properly. EDARM ED-7100 is one of the simplest models of the robotic arm, which has a manual controller to control the movement of the robotic arm. In order to improve this control s

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Journal Of Engineering
Design of a PID-Lead Compensator for a Twin Rotor Aerodynamic System (TRAS)
...Show More Authors

This paper deals with a Twin Rotor Aerodynamic System (TRAS). It is a Multi-Input Multi-Output (MIMO) system with high crosscoupling between its two channels. It proposes a hybrid design procedure that combines frequency response and root locus approaches. The proposed controller is designated as PID-Lead Compensator (PIDLC); the PID controller was designed in previous work using frequency response design specifications, while the lead compensator is proposed in this paper and is designed using the root locus method. A general explicit formula for angle computations in any of the four quadrants is also given. The lead compensator is designed by shifting the dominant closed-loop poles slightly to the left in the s-plane. This has the effect

... Show More
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
MEASURING OF FARMERS ADOPTION LEVEL FOR MODERN IRRIGATION SYSTEM AND THEIR WIDE APPLICATION
...Show More Authors

74 fanners were randomily selected from the Lc:ital. of 406 fanners using the Modern Irrigation System up to November , 2000 , for the purpose of wide adoptation of such system. Rcsults indicated according to the data which has been obtained and statistically analysed by the statistical package for the Social Sciences (SPSS) program showed that the majority of the farmers adopted this new system of irrigation due to the increase in the yield up to 5" .

View Publication Preview PDF
Publication Date
Tue Jun 23 2026
Journal Name
Journal Of Physical Education
Analytical Study of Goalkeeper Positioning Using MH System for Free Kick in Soccer
...Show More Authors

View Publication
Publication Date
Mon Sep 01 2014
Journal Name
Al-khwarizmi Engineering Journal
Using TermoDeck System for Pre-Cooling/ Heating to Control the Building Inside Conditions
...Show More Authors

In this paper, experimental study has been done for temperature distribution in space conditioned with Ventilation Hollow Core Slab (TermoDeck) system. The experiments were carried out on a model room with dimensions of (1m 1.2m 1m) that was built according to a suitable scale factor of (1/4). The temperature distributions was measured by 59 thermocouples fixed in several locations in the test room. Two cases were considered in this work,  the first one during unoccupied period at night time (without external load) and the other at day period with external load of 800W/m2 according to solar heat gain calculations during summer season in Iraq. All results confirm the use of TermoDeck system for ventilation and cooling/heat

... Show More
View Publication Preview PDF
Publication Date
Wed May 31 2017
Journal Name
Journal Of Engineering
Design and Implementation of Classical Sliding Mode Controller for Ball and Plate System
...Show More Authors

Ball and Plate (B&P) system is a benchmark system in the control engineering field that has been used to verify many control methods. In this paper the design of a sliding mode . controller has been investigated and verified in real-time via implementation on a real ball and plate system hardware. The mathematical model has been derived and the necessary parameters have been measured. The sliding mode controller has been designed based on the obtained mathematical model. The resulting controller has been implemented using the Arduino Mega 2560 and a ball and plate system built completely from scratch. The Arduino has been programmed by the Arduino support target for Simulink. Three test signals has been used for verification purposes

... Show More
View Publication Preview PDF