Objective This study aims to investigate the impact of integrated training on kinematics variables and defensive accuracy in volleyball, focusing on enhancing balance and muscle tension control through proprioceptive neuromuscular facilitation (PNF) exercises. Methods The sample consisted of 14 male volleyball athletes from the first volleyball league of Al-Jaish Sports Club were divided into experimental (n=7) and control group (n=7). In the pre- and post-intervention periods, dynamic balance, muscle tension control and kinematic variables (during a lateral reaching task) as well as defensive performance accuracy upon fatigue onset of recoil laser strikes were assessed. Exposure the intervention program was carried out for six weeks, and the following measuring tools were used to assess performance, Y-Balance Test as well as sEMG and kinematic variables using Kinovea. Results Compared with the control- group, individuals in the experimental- group demonstrated significantly improved performance at balance (Y-Balance Test, Cohen's d = 1.42), muscle activity and tension control (sEMG, Cohen's d = 1.38) and defensive ability accuracy (Cohen's d = 1.60). Kinematic variables revealed moderate to large enhancements in knee, hip, shoulder, elbow ankle and trunk angles where effect size ranged from 1.03 to 1.49 (Cohen's d). Control group, as expected, showed mild changes in all studied variables. Conclusion The combined training program enhanced volleyball players’ biomechanical efficiency and defensive performance, highlighting its potential to boost performance, reduce injury risk, and improve coaching effectiveness.
In this work, porous silicon gas sensor hs been fabricated on n-type crystalline silicon (c-Si) wafers of (100) orientation denoted by n-PS using electrochemical etching (ECE) process at etching time 10 min and etching current density 40 mA/cm2. Deposition of the catalyst (Cu) is done by immersing porous silicon (PS) layer in solution consists of 3ml from (Cu) chloride with 4ml (HF) and 12ml (ethanol) and 1 ml (H2O2). The structural, morphological and gas sensing behavior of porous silicon has been studied. The formation of nanostructured silicon is confirmed by using X-ray diffraction (XRD) measurement as well as it shows the formation of an oxide silicon layer due to chemical reaction. Atomic force microscope for PS illustrates that the p
... Show MoreThis paper describes the transport of Alkaloids through Rotating Discs Contactor (RDC) using n-decane as a liquid membrane. The transport of Pelletierine Alkaloid from a source phase through bulk liquid membrane to the receiving phase has been investigated. The general behaviour of Pertraction process indicates that% Extraction of pelletierine Alkaloid increased with increase in the number of stages and the agitation speed but high agitation speed was not favoured due to the increased risk of droplet formation during the operation. The pH of source and receiving phases were also investigated. The effect of organic solvent membrane on the extraction of Pelletierine was evaluated using ndecane, n-hexane and methyl cyclohexane. The results sho
... Show MoreThis work was included external morphological study of horse fly Tabanus indrae Hauser 1939 new record in Iraq, which belongs to family: Tabanidae order: Diptera. The study was involved the most important taxonomic external characters of the: head, thorax, abdomen and their appendages which are: antenna, maxillary palp, wings, legs, spotting in coloring pattern and female genitalia of abdomen
The aim of this research work is to evaluate the use of 980 nm diode laser in clotting the blood
in the bone socket after tooth extraction. The objective is to prevent possible clot dislodgement which is
a defect that may lead to possible infection. A number of rabbits were irradiated using 980nm CW mode
diode laser, 0.86W power output for 9s and 15s exposure time. The irradiated groups were studied
histopathologically in comparison with a control group. Results showed that laser photothermal
coagulation was of benefit in minimizing the possibility of the incidence of postoperative complications.
The formation of the clot reduces the possibility of bleeding and infection.
Static loads exposing to mechanical components can cause cracks, which are lead to form stress concentration regions causing the failure of structure. Generally, from 80% to 90% of structure failure is due to initiation of the cracks. Therefore, it is necessary to repair the crack and reduce its effect on the structure where the effect of the crack is modelled as an additional flexibility to the structure. In the last few years, piezoelectric materials have been considered as one of the most favourable repairing techniques. The piezoelectric material converts the applied voltage on it to a bending moment to counter the bending moment caused by the external load on the beam at the crack location. In this study, the design of the piez
... Show MoreThis research dealt with shedding light on the nature of material misrepresentations, in addition to knowing the extent to which the quality of accounting information systems contributes to reducing material misrepresentations On the theoretical side, a number of sources were relied upon in dealing with the research problem and presentation of the topic, while in the practical side, it was relied on the questionnaire form, where the research sample was (accountants and auditors), where 50 forms were distributed and 50 were received, and the data was analyzed and hypotheses tested through the program Statistical spss to show the relationship between the variables. The research reached a number of conclusions, the most important of which is t
... Show MoreUndoped and Iodine (I)–doped chrome oxide (Cr2O3)thin films have been prepared by chemical spray pyrolysis technique at substrate temperatures(773K) on glass substrate. Absorbance and transmittance spectra have been recorded as a function of wavelength in the range (340-800 nm) in order to study the optical properties such as reflectance, Energy gap of allowed direct transition, extinction coefficient refractive index, and dielectric constant in real and imagery parts all as a function of wavelength. It was found that all the investigated parameters affect by the doping ratios.
This study focuses on studying the effect of reinforced steel in detail, and steel reinforcement (tensile ratio, compression ratio, size, and joint angle shape) on the strength of reinforced concrete (compressive strength) Fc' and searching for the most accurate details of concrete divisions, their behavior, and corner resistance of reinforced concrete joint. The comparison of this paper with previous studies, especially in the studied properties. The conclusions of the chapter are summarized that these effects had a clear effect and a specific effect on the behavior and resistance of the reinforced concrete corner joints under the negative moments and under their influence and the resulting stress conditions. The types of defects that can
... Show More