ABSTRACT:. The Lower Cretaceous Zubair formation is comprised of sandstones intercalated with shale sequences. The main challenges that were encountered while drilling into this formation included severe wellbore instability-related issues across the weaker formations overlaying the reservoir section (pay zone). These issues have a significant impact on well costs and timeline. In this paper, a comprehensive geomechanical study was carried out to understand the causes of the wellbore failure and to improve drilling design and drilling performance on further development wells in the field. Failure criteria known as Mogi-Coulomb was used to determine an operating mud weight window required for safe drilling. The accuracy of the geomechanical model was examined by comparing predicted wellbore instability with the actual wellbore failure shown on caliper logs at a given mud weight. The analysis identified the cause of wellbore instability, as being inadequate mud weight while drilling the overlying shale formation. In addition, this case demonstrated that the safe operating mud weight window was found in the range of 1.35–1.55 g/cc, while 1.21 g/cc had been applied in practice. The results of this study can be used as a reference for optimal mud weight selection to mitigate wellbore-stability problems in nearby wells in this field.
The present study include a new developed method of analysis for determination of drug Spironolaction (SP) in some Pharmaceuticals by Spectrofluorometric method. Spironolaction was determined under optimal experimental condition that follows :- The excitation spectrum was (l=351 nm), the emmetion spectrum was (l=518 nm), pH=1, the suitable temperature for reaction 60oC and the optimal time less than (3) minute. The analysis and rang statistical data was:-Linear dynamic rang (1-10) ?g.ml-1, the detection limit (D.L = 0.023 ?g.ml-1), Molar absorptivity (? = 29875 liter mole-1 cm-1), Relative standard deviation (%RSD = 0.78), (%Erel = 3.3) and recovery (Rec = 96.6) percentage. Determination of Spironolactone was accomplished by two methods
... Show MoreBackground: Evaluation and measurement of primary stability could be achieved by several methods, including the resonance frequency analysis (RFA) and implant insertion torque (IT) values. The need for a sufficient primary stability, guaranteed by an adequate insertion torque and implant stability quotient values, increased its importance mainly in one stage implants or in immediate loading protocols. The aims of this study was to find if there is a correlation between the peak insertion torque (PIT) and ISQ values of implants inserted in the jaws of different bone quality which regarded as two important clinical determinant factors for prediction of implant primary stability, and to evaluate and compare whether an experienced clinician cou
... Show MoreA new colorimetric-flow injection method has been developed and validated for the detection of Cefotaxime sodium in pharmaceutical formulations. This method stands out for its rapid and sensitive nature. The formation of a brown-colored complex between Cefotaxime sodium and the Biuret reagent in a highly alkaline environment serves as the basis for the detection. The intensity of this colored complex is measured using a custom-built Continuous Flow Injection Analyzer, enabling accurate quantification of Cefotaxime sodium. Optimization studies of the chemical and physical parameters such as dilution of Biuret reagent, effect of the medium basicity, flow rate, sample loop and others have been investigated. The calibration gra
... Show MoreAn easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,
... Show MoreCryptosporidiosis is an intestinal protozoan parasitic disease that infects human and animals, caused by apicomplexan parasite belong to the genusof Cryptosporidium. The current study was done to record the infection rate of cryptosporidiosis in human and cattle, and genotype the clinical isolates of Cryptosporidium in Baghdad Province. A total of 265 stool sample were collected (150 from human and 115 from cattle) during the period from December 2016 to the May 2017. Cryptosporidial infection was detected using modified acid fast stain. DNA of the parasite was extracted from oocysts of positive fecal samples and nested PCR method was used for partial 60 kDa glycoprotein (gp60) gene amplification then sequence analysis for selected samples.
... Show MoreThe present investigation is concerned primarily with sorting and identification of subfamily Tubificinae from River Tigris and some water surface in Baghdad /Iraq . For this purpose six study sites were chosen, including a Al- Kadhemyia drainage canal, North Baghdad; three sites on the shore of River Tigris; in addition to site in Al-Jaish canal , East Baghdad, finally the sixth site was from pond in Al-Zawra'a park , within the center of Baghdad .These sites were characterized by sediment rang from clay, silty-clay to silty with a percentage of organic matter ranged between 0.7% - 9.9% . According to water temperature, salinity and pH values, they were nearly identical in all study sites, the water temperature was ranged through the study
... Show More