Preferred Language
Articles
/
1Ya6o4YBIXToZYALYpup
Safe Mud Weight Window Determination: A Case Study from Southern Iraq
...Show More Authors

ABSTRACT:. The Lower Cretaceous Zubair formation is comprised of sandstones intercalated with shale sequences. The main challenges that were encountered while drilling into this formation included severe wellbore instability-related issues across the weaker formations overlaying the reservoir section (pay zone). These issues have a significant impact on well costs and timeline. In this paper, a comprehensive geomechanical study was carried out to understand the causes of the wellbore failure and to improve drilling design and drilling performance on further development wells in the field. Failure criteria known as Mogi-Coulomb was used to determine an operating mud weight window required for safe drilling. The accuracy of the geomechanical model was examined by comparing predicted wellbore instability with the actual wellbore failure shown on caliper logs at a given mud weight. The analysis identified the cause of wellbore instability, as being inadequate mud weight while drilling the overlying shale formation. In addition, this case demonstrated that the safe operating mud weight window was found in the range of 1.35–1.55 g/cc, while 1.21 g/cc had been applied in practice. The results of this study can be used as a reference for optimal mud weight selection to mitigate wellbore-stability problems in nearby wells in this field.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
International Journal Of Pharmaceutical Research
Sensitive Spectrophotometric Determination of Doxycycline in Pure and Dosage Forms using p-Bromanil
...Show More Authors

View Publication
Publication Date
Thu Sep 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Determination of Surface Roughness and Accuracy of Alginate Impression Material Disinfected by Immersion
...Show More Authors

Background: This study was conducted to evaluate the surface roughness and dimensional accuracy of commercially obtainable alginate impression material in terms of imbibition after immersion in two different media. Materials and method: Two disinfecting agents, ethanol 70% and povidone-iodine 4%, were used to access the dimensional accuracy and surface roughness of alginate impression material. Weights of specimen discs of alginate impressions were measured before and immediately after immersion to gain a measure of imbibition. For surface roughness, disinfected specimens rectangle was examined before and after disinfection. Results: Minimal changes in weight were observed after disinfection, but a statistically non-significant differenc

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (23)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of The College Of Basic Education
Simultaneous Determination of Cephalexin and Cefixime by First and Second Derivative Ultraviolet Spectrophotometry
...Show More Authors

A new spectrophotometric method for individual and simultaneous determination of cefixime and cephalexin depending on the first and second derivative mode techniques. The first and second derivative spectra of these compounds permitted individual and simultaneous determination of cefixime and cephalexin in concentration interval of (4– 24μg.ml-1 ) by measuring the amplitude of peak-to-base line, pea to peak at certain wavelengths and the area under peak at selected spectrum intervals. The methods showed reasonable precision and accuracy and have been applied to determine cefixime and cephalexin in two different pharmaceutical preparations.

Publication Date
Thu Feb 29 2024
Journal Name
Iraqi Journal Of Science
Determination of the Physical Properties of the Protoplanetary Disk Around WW Cha Stars
...Show More Authors

     The main goal of this work is to put a simple model of the spectral energy distribution of binary stars called WW Cha. This model is built up on the extracted data from various telescopes and archives for the target WW Cha stars and then analyzing them using a python environment. The result of the fitting proposes that there are two protoplanetary disks around the WW Cha star, with different physical properties for each disk, such as the size of the inner disk being 10 AU, while the size of the outer disk being 300 AU. The shape of the outer disk is a flaring disk not a flat disk according to the value of the power law for the surface density (1.5). The emission in the disk is caused by small amorphous olivine grains rangin

... Show More
View Publication
Scopus Crossref
Publication Date
Sat Dec 15 2018
Journal Name
Revista De Chimie
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which

... Show More
Crossref (4)
Crossref
Publication Date
Tue May 01 2012
Journal Name
Iraqi Journal Of Physics
Determination the dispersion parameters and urbach tail of iron chromate doped PMMA films
...Show More Authors

Films of pure Poly (methyl methacrylate) PMMA and Iron chromate doped PMMA have been prepared using casting method. Transmission and absorptance spectra have been recorded in the wavelength range (300-900) nm, in order to calculate, single oscillator energy, dispersion energy proposed by Wemple - DiDomenico model, average oscillator strength, average oscillator wavelength. The refractive index data at infinite wavelength which was found to obey single oscillator model which was found to increase from 2.27-2.56 as the doping percentage increase. The decreasing in the optical energy gap which was found according to Tauc model were (3.74-3.63) eV , is in good agreement with that obtained by wimple-DiDomenico model. The inverse behavior comp

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 23 2020
Journal Name
Baghdad Science Journal
Quantitative Determination of Fluoroquinolones in Contaminated Soils by HPLC with Solid-Phase Extraction
...Show More Authors

This work reports the development of an analytical method for the simultaneous analysis of three fluoroquinolones; ciprofloxacin (CIP), norfloxacin (NOR) and ofloxacin (OFL) in soil matrix. The proposed method was performed by using microwave-assisted extraction (MAE), solid-phase extraction (SPE) for samples purification, and finally the pre-concentrated samples were analyzed by HPLC detector. In this study, various organic solvents were tested to extract the test compounds, and the extraction performance was evaluated by testing various parameters including extraction solvent, solvent volume, extraction time, temperature and number of the extraction cycles. The current method showed a good linearity over the concentration ranging from

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Determination of time-dependent coefficient in inverse coefficient problem of fractional wave equation
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Mon Feb 01 2010
Journal Name
Food Chemistry
Determination of aflatoxins in animal feeds by HPLC with multifunctional column clean-up
...Show More Authors

A reversed-phase HPLC method with fluorescence detection for the determination of the aflatoxins B1, B2, G1 and G2 in 42 animal feeds, comprising corn (16), soya bean meal (8), mixed meal (13), sunflower, wheat, canola, palm kernel, copra meals (1 each) was carried out. The samples were first extracted using acetonitrile:water (9:1), and was further cleaned-up using a multifunctional column. Optimum conditions for the extraction and chromatographic separation were investigated. By adopting an isocratic chromatographic system using a mobile phase comprising acetonitrile:methanol:water (8:27:65, v/v/v), the separation of the four aflatoxins was possible within 30 min. Recoveries for aflatoxins B1, B2, G1 and G2 were 98 ± 0.7%, 95 ± 1.0%, 94

... Show More
View Publication
Scopus (122)
Crossref (108)
Scopus Clarivate Crossref