Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for the purpose of orthodontic treatment and with fully-formed roots, were used in this study. Endodontic access cavity was prepared in each tooth and canal patency up to the apical foramen was checked with a #15 stainless steel K-file. No root canal preparation was performed. Root canal length measurement was done directly and electronically using two apex locators (Joypex 5 and Root ZX). Direct measurement of the root canal length was done by introducing a #15 K-file inside the root canal until its tip was just visible at the apical foramen, then removed from the root canal and its length was measured (in mm) and subtracted by 0.5 mm. For electronic measurement, the teeth were fixed in a sponge soaked in saline and the root canals were also filled with saline. The lip electrode was attached to the sponge and the apex locators were used according to the manufacturers' instructions. The file holder was clipped to the metal shaft of a #15 K-file and the file was then inserted inside the root canal and advanced until the display reading on the LCD of the apex locator was "0.5". The file was then removed from the root canal and its length was measured (in mm). The differences between the readings of each apex locator and the actual length of each canal were computed, and the results were analyzed statistically by paired t-test using SPSS Version 13. Results: The results of this study showed that the Joypex 5 apex locator showed a lower mean difference than the Root ZX apex locator as compared with the actual length, which was statistically significant (p<0.05). Concerning the accuracy of the two apex locators, Joypex 5 apex locator recorded the apical constriction exactly in 67%, while the Root ZX apex locator in only 25%. Within ±0.5 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 83% and 67%, respectively. Within ±1 mm from the actual length, the accuracy of the Joypex 5 and the Root ZX were 100% and 96%, respectively. Conclusion: The Joypex 5 apex locator which is a fifth generation apex locator was more accurate in recording the apical constriction as compared with the Root ZX apex locator which is a third generation apex locator.
Removal of Congo red, Rhodamine B, and Dispers Blue dyes from water solution have been achieved using Flint Clay as an adsorbent. The adsorption was studied as a function of contact time, adsorbent dose, pH, and temperature under batch adsorption technique. The equilibrium data fit with Langmuir, Freundlich and Toth models of adsorption and the linear regression coefficient R2 was used to elucidate the best fitting isotherm model. Different thermodynamic parameters, namely Gibb’s free energy, enthalpy and entropy of the on-going adsorption process have also been evaluated. Batch technique has been employed for the kinetic measurements and the adsorption of the three dyes follows a second order rate kinetics. The kinetic investigations al
... Show MorePure grade II titanium disks were coated with a thin coating of polyetherketoneketone (PEKK) polymer by RF magnetron sputtering using either nitrogen or argon gas. Sputtering technique was employed at 50 W for one hour at 60°C with continuous flow of nitrogen or argon gas. Field-emission scanning electron microscopy (FE-SEM) showed a continuous, homogeneous, rough PEKK surface coating without cracks. In addition, cross-sectional FE-SEM revealed an average coat thickness of 1.86 μm with argon gas and 1.96 μm with nitrogen gas. There was homogenous adhesion between the coating layer and substrate. The elemental analysis of titanium substrate revealed the presence of carbon, titanium, and oxygen. The RF magnetron sputtering with argon or ni
... Show MoreWith the development of cloud computing during the latest years, data center networks have become a great topic in both industrial and academic societies. Nevertheless, traditional methods based on manual and hardware devices are burdensome, expensive, and cannot completely utilize the ability of physical network infrastructure. Thus, Software-Defined Networking (SDN) has been hyped as one of the best encouraging solutions for future Internet performance. SDN notable by two features; the separation of control plane from the data plane, and providing the network development by programmable capabilities instead of hardware solutions. Current paper introduces an SDN-based optimized Resch
Polycrystalline Cadmium Oxide (CdO) thin films were prepared
using pulsed laser deposition onto glass substrates at room
temperature with different thicknesses of (300, 350 and 400)nm,
these films were irradiated with cesium-137(Cs-137) radiation. The
thickness and irradiation effects on structural and optical properties
were studied. It is observed by XRD results that films are
polycrystalline before and after irradiation, with cubic structure and
show preferential growth along (111) and (200) directions. The
crystallite sizes increases with increasing of thickness, and decreases
with gamma radiation, which are found to be within the range
(23.84-4.52) nm and (41.44-4.974)nm before and after irradiation for
Purpose: To assess the antioxidant and antineoplastic effects of Hibiscus sabdariffa Linn. on oral squamous cell carcinoma cells. Materials and Methods: Human squamous cell carcinoma HSCC cells were tested for cytotoxicity by a methanol extract of Hibiscus sabdariffa (MEHSP). After 24, 48, and 72 ...
Phase change materials are extensively studied for use in low-, mid-, and high-temperature applications due to their melting and solidification temperatures, latent heat, and thermophysical properties. This work aims to explore the energy stored, or released and their duration for the energy storage unit formed of a phase change material surrounding a tube within which a hot or cold, single or Two-Phase fluid flows, serving as a heat source or sink. The 3D axial transient thermal analysis of the energy storage unit is performed using the finite element method via a MATLAB-developed computer program. The effects of single- or Two-Phase fluid flow on temperature distribution, solidification, melting duration, and energy stored within phase ch
... Show MoreBasketball is a popular game in many parts of the world and many developed countries are making continuous efforts to prepare and develop their emerging players on scientific and clear bases as the basis for reaching high levels The researchers used the descriptive approach in the method of correlative studies to suit the nature of the study The readymade software (IBM SPSS Statistics Version24) was used to perform statistical treatments The researchers concluded that there was a significant relationship between body size indicators (height and weight) with the fitness elements of the emerging basketball players The researchers recommended conducting a similar study to determine the type of relationship to the indicators of the physical str
... Show MoreExtract from cell culture of medicinal plant like Nigella sativa have been assessed for its cytotoxic properties. Thymol is likely responsible for the theraputic effects of Nigella sativa leaf callus extract. In this short study the inhibitory effect of Nigella sativa leaf callus extract (Thymol) has been studied on Human Lorgnx Epidrmoid Carcinoma (Hep-2) cell line during different exposure period of time (24, 48 and 72 hrs.) using different concentration of the extract (1000, 500, 400, 300, 200 and 100 µg/ml). The optical density of the Hep-2 cells has been readed on 492 nm wave length. Thymol –induced cytotoxicity was (500 µg/ml) which inhibit cell growing compared to the control and this
... Show More