Preferred Language
Articles
/
1BeUX5MBVTCNdQwCetKO
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors. Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II. Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.

Publication Date
Mon Jan 01 2018
Journal Name
Matec Web Of Conferences
Effect of internal curing on performance of self-compacting concrete by using sustainable materials
...Show More Authors

This paper is devoted to investigate the effect of internal curing technique on the properties of self-compacting concrete. In this study, self-compacting concrete is produced by using limestone powder as partial replacement by weight of cement with percentage of (5%), sand is partially replaced by volume with saturated fine lightweight aggregate which is thermostone aggregate as internal curing material in three percentages of (5%, 10%, 15%) for self-compacting concrete, and the use of two external curing conditions which are water and air. The experimental work was divided into three parts: in the first part, the workability tests of fresh self-compacting concrete were conducted. The second part included conducting compressive str

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Tue Jun 11 2024
Journal Name
International Journal Of Civil Engineering
Strength Evaluation of CFRP-Strengthened RC Slab-Beams System by Load Test to Satisfy the Safety Requirements: A Case Study
...Show More Authors

The primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deter

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed May 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Simulation Physical and Chemical Blowing Agents for Polyurethane Foam Production
...Show More Authors
Abstract<p>Use of computer simulation to quantify the effectiveness of blowing agents can be an effective tool for optimizing formulations and for the adopting of new blowing agents. This paper focuses on a mass balance on blowing agent during foaming including the quantification of the amount that stays in the resin, the amount that ends up in the foam cells, and the pressure of the blowing agent in the foam cells. Experimental data is presented both in the sense of developing the simulation capabilities and the validating of simulation results.</p>
View Publication
Scopus (14)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Oct 01 2025
Journal Name
Ieee
Securing Power Microgrids: A Cyber-Physical Approach for Modern Infrastructure
...Show More Authors

With the increasing reliance on microgrids as flexible and sustainable solutions for energy distribution, securing decentralized electricity grids requires robust cybersecurity strategies tailored to microgrid-specific vulnerabilities. The research paper focuses on enhancing detection capabilities and response times in the face of coordinated cyber threats in microgrid systems by implementing advanced technologies, thereby supporting decentralized operations while maintaining robust system performance in the presence of attacks. It utilizes advanced power engineering techniques to strengthen cybersecurity in modern power grids. A real-world CPS testbed was utilized to simulate the smart grid environment and analyze the impact of cyberattack

... Show More
Publication Date
Sun Jan 03 2016
Journal Name
Journal Of Educational And Psychological Researches
Psychological pressure for students who are subject to physical education.
...Show More Authors

The current research involves psychological pressure (educational,environment andemotionly) for secondary level to 2013-2014.This research includes comparison among students who are trained and not trained  in physical education .The sample is(126) students from each gender from first education.Al-Karkh and the research found out that physical education  has an effect in lessing emotional and educational in a big degree in student in secondary  which affect them  positively in their  study.                                     &n

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Physical Education
Body Image and Its Relationship With Self – Confidence In Female College of Physical Education and Sport Sciences Students
...Show More Authors

View Publication
Publication Date
Tue Jan 20 2026
Journal Name
Journal Of Physical Education
Consecutive Case Study of Detraining On Some Functional, Physical, Body and Compound Skills Variables In Advance Basketball Players
...Show More Authors

View Publication
Publication Date
Thu Feb 01 2024
Journal Name
Baghdad Science Journal
Estimating concentration of toxic ions Arsenic in water by using Photonic Crystal Fiber based on Surface Plasmon Resonance (SPR)
...Show More Authors

In this work, an enhanced Photonic Crystal Fiber (PCF) based on Surface Plasmon Resonance (SPR) sensor using a sided polished structure for the detection of toxic ions Arsenic in water was designed and implemented. The SPR curve can be obtained by polishing the side of the PCF after coating the Au film on the side of the polished area, the SPR curve can be obtained. The proposed sensor has a clear SPR effect, according to the findings of the experiments. The estimated signal to Noise Ratio (SNR), sensitivity (S), resolution (R), and Figures of merit (FOM) are approaching; the SNR is 0.0125, S is 11.11 μm/RIU, the resolution is 1.8x〖10〗^(-4), and the FOM is 13.88 for Single-mode Fiber- Photonic Crystal Fiber- single mode Fiber (SMF-P

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (4)
Scopus Crossref
Publication Date
Fri Sep 05 2014
Journal Name
Engineering And Technology Journal
New Method to Increase the Ability of the Water for Dissolving Total Salts in Soil by Using the Magnetism
...Show More Authors

Publication Date
Tue Jan 20 2026
Journal Name
Mustansiriyah University
Inhibition the Expression of fimC, fimD, fimH Genes in Uropathogenic E. coli Using TiO2 Nanoparticles Biosynthesized by Probiotics Bacteria
...Show More Authors

المستودع الرقمي العراقي. مركز المعلومات الرقمية التابع لمكتبة العتبة العباسية المقدسة

View Publication