Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors. Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II. Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.
Abstract
In this manuscript, a simple new method for the green synthesis of platinum nanoparticles (Pt NPs) utilizing F. carica Fig extract as reducing agent for antimicrobial activities was reported. Simultaneously, the microstructural and morphological features of the synthesized Pt NPs were thoroughly investigated. In particular, the attained Pt NPs exhibited spherical shape with diameter range of 5-30 nm and root mean square of 9.48 nm using Transmission Electron Microscopy (TEM) and Atomic Force Microscopy (AFM), respectively. Additionally, the final product (Pt NPs) was screened as antifungal and antibacterial agent against Candida and Aspergillus species as well as Gram-positive Staphyllococcus aureus and G
... Show MoreThere is a great operational risk to control the day-to-day management in water treatment plants, so water companies are looking for solutions to predict how the treatment processes may be improved due to the increased pressure to remain competitive. This study focused on the mathematical modeling of water treatment processes with the primary motivation to provide tools that can be used to predict the performance of the treatment to enable better control of uncertainty and risk. This research included choosing the most important variables affecting quality standards using the correlation test. According to this test, it was found that the important parameters of raw water: Total Hardn
Several directional wells have been drilled in Majnoon oilfield at wide variation in drilling time due to different drilling parameters applied for each well. This technical paper shows the importance of proper selection of the bit, Mud type, applied weight on Bit (WOB), Revolution per minute (RPM), and flow rate based on the previous wells drilled. Utilizing the data during drilling each section for directional wells that's significantly could improve drilling efficiency presented at a high rate of penetration (ROP). Based on the extensive study of three directional wells of 35 degree inclination (MJ-51, MJ-52, and MJ-54) found that the applied drilling parameters for MJ-54 and the bit type within associated drilling parameters to drill
... Show MoreDiabetes mellitus, or simply diabetes, is a group of metabolic diseases in which a person has high blood sugar, either because the pancreas does not produce enough insulin, or because cells do not respond to the insulin that is produced. This high blood sugar produces the classical symptoms of polyuria (frequent urination), polydipsia (increased thirst), and polyphagia (increased hunger). The aim of the study is to measure several biochemical parameters in T2DM patients and the effect of these parameters in development the disease. Laboratory investigations including Ceruloplasmin , fasting blood glucose (FBG) , malondialdehyde (MDA), serum protein, uric acid, and protein electrophoresis have been measured in patients with type
... Show MoreBackground: Dysfunction of sinoatrial node is a set of abnormal rhythms which are resulted from the sinoatrial node malfunction of the sinus node, the chief natural cardiac pacemaker. The common, and occasionally, the single method for treatment of heart arrhythmias was implantation of pacemaker, which reduce symptoms exactly occurs after implantation. Aim: To detect the role of smoking on cardiac electrophysiology parameters in sinus node dysfunction in Iraqi patients such as SNRT and AH. Methods: A cross sectional study, was conducted on 59 patient ranging between 20-50 years old and involving 35 female and 24 male patients, suffering from an unexplained symptoms of sinoatrial node dysfunction (SND). The enrolled participants were gathere
... Show MoreTerrestrial isopods play an important role in the biodegradation of many wastes which gives agreat importance in the nutrient cycles and ecosystem services , therefore this paper aims to use species
Background: Implantology is a fast growing area in dentistry. One of the most common issues encountered in dental implantation procedures is the lack of adequate preoperative planning. Conventional radiography may not be able to assess the true regional three-dimensional anatomical presentation. Multi Slice Computed Tomography provides data in 3-dimentional format offering information on craniofacial anatomy for diagnosis; this technology enables the virtual placement of implant in a 3-Dimensional model of the patient jaw (dental planning). Patients, Material and Methods: The sample consisted of (72) Iraqi patients indicated for dental implant (34 male and 38 female), age range between (20-70) years old. They were examined during a time p
... Show MoreThis article aim to estimate the Return Stock Rate of the private banking sector, with two banks, by adopting a Partial Linear Model based on the Arbitrage Pricing Model (APT) theory, using Wavelet and Kernel Smoothers. The results have proved that the wavelet method is the best. Also, the results of the market portfolio impact and inflation rate have proved an adversely effectiveness on the rate of return, and direct impact of the money supply.
Many of mechanical systems are exposed to undesired vibrations, so designing an active vibration control (AVC) system is important in engineering decisions to reduce this vibration. Smart structure technology is used for vibration reduction. Therefore, the cantilever beam is embedded by a piezoelectric (PZT) as an actuator. The optimal LQR controller is designed that reduce the vibration of the smart beam by using a PZT element.
In this study the main part is to change the length of the aluminum cantilever beam, so keep the control gains, the excitation, the actuation voltage, and mechanical properties of the aluminum beam for each length of the smart cantilever beam and observe the behavior and effec
... Show MoreElectrophoretic Deposition (EPD) process offers various advantages like the fabrication of the ceramic coatings and bodies with dense packing, good sinterability and homogenous microstructure. The variables namely (applied potential, deposition time and sintering temperature) affected the development of hydroxyapatite (HAP) coatings. The coating weight and thickness were found to increase with the increase in applied potential or coating time. Sintering temperature was found to affect in change phases of the metal, furthermore the firing shrinkage of the HAP coating on a constraining metal substrate leads to serve cracking. XRD Characterization indicates the formation of a contamination free phase pure, and the optical micrographs show th
... Show More