Preferred Language
Articles
/
1BeUX5MBVTCNdQwCetKO
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors. Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II. Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.

Publication Date
Wed Jan 02 2019
Journal Name
Journal Of Educational And Psychological Researches
A research taken from Dissertation " Artistic Expression by painting among Kindergarten child"
...Show More Authors

The current study aims to identify the artistic expression as well as the aspects of artistic expression by the painting among the kindergarten children. In order to fulfill the research's goals, a sample of (400) children were chosen randomly from 19 public kindergartens of 6 directorates at Al-Rusafa and Al-Karkh in Baghdad city. The children were asked to draw a particular view. The researcher  has adopted  Al-Hamedawi scale  (2009) consisted of  (16) items, which was exposed to group of (25) experts in  psychology, education,  measurement and evaluation,  artistic  education by painting  and plastics  to show  the items reliability. As the researcher applied T-test  for&nbsp

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 16 2017
Journal Name
Signal, Image And Video Processing
Enhancing Prony’s method by nuclear norm penalization and extension to missing data
...Show More Authors

View Publication
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Jun 27 2019
Journal Name
Molecular Crystals And Liquid Crystals
Supramolecular columnar discotic nematic liquid crystal by hydrogen bonding: Synthesis and characterization
...Show More Authors

The design, synthesis, and characterization of a star shaped 2,4,6-tris-(4`-carboxyphenoxy)-1,3,5-triazine liquid crystalline with columnar discotic mesophase properties establish H-bond interactions with 3,5-dialkoxypyidine were reported. The structures of the synthesized compounds were actually determined by elementary analysis, and FT-IR, ¹HNMR, ¹³CNMR, and mass spectroscopy. The mesomorphic properties of these mesogens were examined using differential scanning calorimetry (DSC) and optical polarizing microscopy (OPM). The synthesized molecules exhibited enantiotropic hexagonal columnar liquid crystal, which depends for the H- bond complex in a 1:3 ratio.

Scopus (14)
Scopus
Publication Date
Wed Jan 01 2020
Journal Name
International Journal Of Computational Intelligence Systems
Evolutionary Feature Optimization for Plant Leaf Disease Detection by Deep Neural Networks
...Show More Authors

View Publication
Scopus (55)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Mon Jan 02 2012
Journal Name
Karbala Journal Of Medicine
Open Tibial Shaft Fractures Treated By Primary External Fixation And Bone Graft
...Show More Authors

Eprospective study undertaken between January 2007 and January 2011, 58 consecutive cases with compound tibial shaft fractures. All fractures were stabilized by external fixator device AO/ASIF type after failed the manipulation under anesthesia (MUA) to restore the osseous alignment. In 32 patients cancellous bone graft were used from the upper part of the tibia to enhance healing process, all these patients were followed for an average of 8–12 months. Our findings showed that stabilization of the fracture shaft tibia by external fixation with cancellous bone graft had significantly better result, than external fixation alone. We conclude that unilateral, uniplanar external fixation with early bone grafting from upper part of the tibia is

... Show More
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Uranium and Plutonium Recovery by Tributylphosphate Solvation and Trioctylamine Ion association Mechanisms
...Show More Authors

In this work a flowsheet has been put for the recovery of uranium and plutonium from 2.5M nitric acid solutions using 17.5% tributyl phosphate (TBP) and 2.5% trioctylamine (TOA) in kerosene diluent . The fission products (resulting from irradiated of uranium samples in nuclear research reactor) were removed from the desired actinides U & Pu .The organic phase TBP/TOA/Kerosene, containing both actinides U&Pu were stripped using 0.1 M HNO3. Trioctylamine (2.5 volume ratio ) in mesitylene , has been used in conditions appropriate for the recovery of Pu . From the experiments done using mixer- settler , the concentration of uranium in the organic phase in such conditions was very low ,not exceeding parts of a million .

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 02 2018
Journal Name
Iraqi Journal Of Physics
Optical properties for TiO2 / PMMA nanocomposite thin films prepared by plasma jet
...Show More Authors

PMMA/TiO2 homogeneous thin films were deposited by using plasma jet system under normal atmospheric pressure and room temperature. PMMA/TiO2 nanocomposite thin film synthesized by plasma polymerization. Titanium oxide was mixed with Methyl Methacrylate Monomer (MMA) with specific weight ratios (1, 3 and 5 grams of TiO2 per 100 ml of MMA). Optical properties of PMMA/TiO2 nanocomposite thin films were characterized by UV-Visible absorption spectra using a double beam UV-Vis-NIR Spectrophotometer. The thin films surface morphological analysis is carried out by employing SEM. The structure analysis are achieved by X-ray diffraction. UV-Visible absorption spectra shows that the increasing the concentration of titanium oxide added to the polym

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Ocean Engineering
Stresses and pore water pressure induced by machine foundation on saturated sand
...Show More Authors

In this study, the response and behavior of machine foundations resting on dry and saturated sand was investigated experimentally. In order to investigate the response of soil and footing to steady state dynamic loading, a physical model was manufactured. The manufactured physical model could be used to simulate steady state harmonic load at different operating frequencies. Total of (84) physical models were performed. The parameters that were taken into considerations include loading frequency, size of footing and different soil conditions. The footing parameters were related to the size of the rectangular footing and depth of embedment. Two sizes of rectangular steel model footing were used (100 200 12.5 mm) and (200 400 5.0 mm).

... Show More
View Publication
Crossref (26)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Optical and structural study for DLC thin films prepared by plasma jet
...Show More Authors

Diamond-like carbon (DLC) homogeneous thin films were deposited from cyclohexane (Ccyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (Ccyclohexane (C cyclohexane (Ccyclohexane (C 6H12 ) liquid by using a plasma jet system which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with alternating high voltage 7.5 which operates with alternating high voltage 7.5which operates with al

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 06 2014
Journal Name
Plos One
Hepatic Carboxylesterase 1 Is Induced by Glucose and Regulates Postprandial Glucose Levels
...Show More Authors

View Publication
Scopus (34)
Crossref (24)
Scopus Clarivate Crossref