Preferred Language
Articles
/
1BeUX5MBVTCNdQwCetKO
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors. Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II. Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.

Publication Date
Tue Feb 12 2019
Journal Name
International Journal Of Biosciences
Biomechanical and histological assessment of titanium dental implants coated with strontium substituted hydroxyapatite and fluorapatite mixture
...Show More Authors

Dental implants are considered a unique treatment alternative for the replacement of missing dentition. There is a strive for materials which increase bone formation in bone implant interface and improve osseointegration to offer immediate loading directly after placement with decreased time. The aim of the study was to assess the effect of nano strontium substituted hydroxyapatite and nano fluorapatite mixture coating of screw shaped commercially pure titanium at the bone implant interface by torque removal test and histological assessment in rabbit tibia. Commercially pure titanium was used to prepare 80 screws that were divided into machined surfaces (CpTi), coated with (SrHA), coated with (FA) and coated with mixture 50%SrHA + 50%FA (mi

... Show More
Preview PDF
Publication Date
Tue Oct 20 2020
Journal Name
International Journal Of Civil Engineering
Structural Performance Under Monotonic Static Loading of Reinforced Concrete Gable Roof Beams with Multiple Web Openings
...Show More Authors

In the present study, an attempt has been made to experimentally investigate the flexural performance of ten simply supported reinforced concrete gable roof beams, including solid control specimen (i.e., without openings) and nine beams with web openings of different dimensions and configurations. The nine beams with openings have identical reinforcement details. All beams were monotonically loaded to failure under mid-span loading. The main variables were the number of the created openings, the total area of the created openings, and the inclination angle of the posts between openings. Of interest is the load-carrying capacity, cracking resistance and propagation, deformability, failure mode, and strain development that represent the behav

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Technological route and characteristics of home - built Ag, Ag/Cu, and Ag/Ni ohmic conductor pastes
...Show More Authors

The current research reports the preparation and fabrication of the silver paste conductor which is employed as a soldering material for electro – optical components ohmic interconnections. The prepared paste possesses electrical characteristics identical to the ohmic connectors as its observable from resistance – temperature variation. Moreover, the I – V characteristics obeys Ohm’s law and this dependency was further confirmed by the nearly constant capacitance measurements with voltage and frequency. A noticeable improvement in electrical conductivity, compared to the pure silver paste sample, was noted for samples prepared by mixing predetermined weight ratios of brass and copper. Furthermore, stability of electrical resistan

... Show More
View Publication Preview PDF
Publication Date
Mon Jun 10 2019
Journal Name
Journal Of Global Pharma Technology
Mixed Ligand Schiff Base Complexes of Some Meta(II) Salts: Preparation. Spectral Characterization and Antibacterial Screening
...Show More Authors

FH Ghanim, Journal of Global Pharma Technology, 2018

View Publication
Publication Date
Sun Jan 02 2011
Journal Name
College Of Education Journal, Al-mustansiriyah University
The cyclic Decomposition of PSL(2,pk) where pk = 5, 7, 11, 13, 17 and 19
...Show More Authors

Publication Date
Tue Jun 01 2021
Journal Name
Biochemical And Cellular Archives
SYNTHESIS, CHARACTERIZATION AND BIOLOGICAL STUDY OF NEW COMPLEXES SCHIFF BASE DERIVED FROM 4-BROMO-2-METHYLANIN
...Show More Authors

The mixed ligand complexes of Schiff base ligand (Z)-2-(((4-bromo-2-methylphenyl) imino) methyl)-4-methylphenol (L) with some metals ion (II); Mn(1), Co(2), Ni(3), Cu(4), Zn(5) Cd(6) and Hg(7) and 1,10-Phenanthroline (phen) were Synthesis and characterized by the mass and 1HNMR spectrometry (ligand Schiff base), the FTIR, UV-visible and the flame atomic absorption (A.A) spectrum, the C.H.N analysis and the chlorine content, in addition to measuring the magnetic sensitivity of the complexes. All the complexes had octahedral geometry. The bioactivity activity for compounds against; Rhizopodium, Staphylococcus aureus and Escherichia coli, the compounds showed different efficacy towards these microorganisms

Publication Date
Mon Jun 01 2020
Journal Name
Iraqi Journal Of Physics
Optimum diameter for laser beam and effect of temperature rise on the optical bistability hysteresis loops
...Show More Authors

 In this research, analytical study for simulating a Fabry-Perot bistable etalon (F-P cavity) filled with a dispersive optimized nonlinear optical material (Kerr type) such as semiconductors Indium Antimonide (InSb). An optimization procedure using reflective (~85%) InSb etalon (~50µm) thick is described. For this etalon with a (50 µm) spot diameter beam, the minimum switching power is (~0.078 mW) and switching time is (~150 ns), leading to a switching energy of (~11.77 pJ) for this device. Also, the main role played by the temperature to change the etalon characteristic from nonlinear to linear dynamics.

View Publication Preview PDF
Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Comparison of Maximum Likelihood and some Bayes Estimators for Maxwell Distribution based on Non-informative Priors
...Show More Authors

In this paper, Bayes estimators of the parameter of Maxwell distribution have been derived along with maximum likelihood estimator. The non-informative priors; Jeffreys and the extension of Jeffreys prior information has been considered under two different loss functions, the squared error loss function and the modified squared error loss function for comparison purpose. A simulation study has been developed in order to gain an insight into the performance on small, moderate and large samples. The performance of these estimators has been explored numerically under different conditions. The efficiency for the estimators was compared according to the mean square error MSE. The results of comparison by MSE show that the efficiency of Bayes est

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jun 02 2013
Journal Name
Baghdad Science Journal
Comparison of Maximum Likelihood and some Bayes Estimators for Maxwell Distribution based on Non-informative Priors
...Show More Authors

In this paper, Bayes estimators of the parameter of Maxwell distribution have been derived along with maximum likelihood estimator. The non-informative priors; Jeffreys and the extension of Jeffreys prior information has been considered under two different loss functions, the squared error loss function and the modified squared error loss function for comparison purpose. A simulation study has been developed in order to gain an insight into the performance on small, moderate and large samples. The performance of these estimators has been explored numerically under different conditions. The efficiency for the estimators was compared according to the mean square error MSE. The results of comparison by MSE show that the efficiency of B

... Show More
Preview PDF
Crossref (2)
Crossref
Publication Date
Mon May 01 2017
Journal Name
Journal Of The Mechanical Behavior Of Biomedical Materials
Bioactivity, cytocompatibility and thermal properties of experimental Bioglass-reinforced composites as potential root-canal filling materials
...Show More Authors

To evaluate the bioactivity and the cytocompatibility of experimental Bioglass-reinforced polyethylene-based root-canal filling materials. The thermal properties of the experimental materials were also evaluated using differential scanning calorimetry, while their radiopacity was assessed using a grey-scale value (GSV) aluminium step wedge and a phosphor plate digital system. Bioglass 45S5 (BAG), polyethylene and Strontium oxide (SrO) were used to create tailored composite fibres. The filler distribution within the composites was assessed using SEM, while their bioactivity was evaluated through infrared spectroscopy (FTIR) after storage in simulated body fluid (SBF). The radiopacity of the composite fibres and their thermal properties were

... Show More
View Publication Preview PDF
Crossref (30)
Crossref