Preferred Language
Articles
/
1BeUX5MBVTCNdQwCetKO
Evaluation of physical parameters in mitral valve stenosis by using Doppler Ultrasound
...Show More Authors

Background: Mitral valve stenosis is a condition in which the hearts mitral valve is narrowed (stenosis), This narrowing blocks the valve from opening properly obstructing blood flow through the heart and the rest of the body and this causes changes in physical parameters (resistance and conductance). Aim of the study: To assess the changes in the physical parameters in mitral valve stenosis disease in different gender and age by using Doppler ultrasound. Methods : The examination of patients at the Division of Echo - at the Iraqi Center for Heart Disease in Medical City for surgery specialist - Baghdad - Iraq, during(February2009 till November2010). The current study included fifty eight cases containing (27 males and 31 females) ages ranging between (16- 82) and is divided between 29 people from healthy people (I) which contain (13 males and 16 females) ages ranging between (16- 82) and a standard deviation of 22.6. Twenty nine of patients with mitral valve stenosis were divided into group (II) contains (6 males and 8 females) ages ranging between (28-76) and the standard deviation of 17.8, group (III) contains (5 males and 4 females) ages ranging between (40-71) and the standard deviation of 16.1 and group (IV) contain (3 male and 3 female) ages ranging between (56-72) and the standard deviation of 17.9. Studying changes developments in physical factors resulting from mitral valve stenosis and depending on these factors were calculated to change the resistance and conductivity and studying the relationship of the change in area and the change of physical factors. Results: The flow rate and area of mitral valve was significantly less in group IV than other groups, but pressure gradient, max velocity, pressure half time, max pressure were higher and more significantly in group IV. Resistance is significantly increases and it is higher in group IV compared with other groups. Conductance is higher in group I but more significant in group II. Conclusion: There is a strong correlation between the pressure half time and area of mitral valve. Resistance was significantly increased and it is higher in sever mitral stenosis. Conductance is high in mild mitral stenosis. The increase in mitral pressure gradient is frequently compensated by a decreased conductance. Age was highly influential but sex exerts less influence to change the physical parameters.

Publication Date
Wed Aug 05 2020
Journal Name
Neuroquantology
The Influence of Some Important Parameters on the Performance Efficiency of the Compound Parabolic Solar Concentrator
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Tue Jun 01 2021
Journal Name
International Journal Of Statistical
Evaluating the performance of introduced varieties of maize (Zea Mays L.) and estimating some genetic parameters
...Show More Authors

Scopus (13)
Scopus
Publication Date
Sat Apr 01 2023
Journal Name
Heliyon
Application of solar photo-electro-Fenton technology to petroleum refinery wastewater degradation: Optimization of operational parameters
...Show More Authors

View Publication
Scopus (19)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Jun 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Combined Effect of Some Internal Ballisting Parameters on the Pressure Behavior of Solid Propellant Rocket Motor
...Show More Authors

View Publication Preview PDF
Publication Date
Fri Jan 01 2021
Journal Name
International Journal Of Agricultural And Statistical Sci.
Evaluating the performance of introduced varieties of Maize (Zea mays L.) And estimating some genetic parameters
...Show More Authors

Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
A Review of the Stereo lithography 3D Printing Process and the Effect of Parameters on Quality
...Show More Authors

Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA t

... Show More
Scopus (20)
Crossref (20)
Scopus Crossref
Publication Date
Mon Jun 05 2023
Journal Name
Al-khwarizmi Engineering Journal
A Review of the Stereo lithography 3D Printing Process and the Effect of Parameters on Quality
...Show More Authors

Stereo lithography (SLA) three-dimensional (3D) printing process is a type of additive manufacturing techniques that uses digital models from computer-aided design to automatically produce customized 3D objects. Around 30 years, it has been widely utilized in the manufacturing, design, engineering, industrial sectors and its applications in dentistry for manufacturing prosthodontics are very important. The stereo lithography technology is highly regarded because it can produce items with excellent precision especially when selecting the best process parameters. This review article offers a useful and scientific summary of SLA three-dimensional printing technology and its brief history. The specific type of 3D printers which is SLA type b

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (20)
Scopus Crossref
Publication Date
Sun Jun 30 2024
Journal Name
Wasit Journal For Pure Sciences
Design Polynomial IIR Digital Filters of the Integer Parameters Space Use to Compress Image Data
...Show More Authors

Polynomial IIR digital filters play a crucial role in the process of image data compression. The main purpose of designing polynomial IIR digital filters of the integer parameters space and introduce efficient filters to compress image data using a singular value decomposition algorithm. The proposed work is designed to break down the complex topic into bite-sized pieces of image data compression through the lens of compression image data using Infinite Impulse Response Filters. The frequency response of the filters is measured using a real signal with an automated panoramic measuring system developed in the virtual instrument environment. The analysis of the output signal showed that there are no limit cycles with a maximum radius

... Show More
View Publication
Crossref
Publication Date
Thu Oct 29 2020
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Testing the New Parameters affecting The Outcome of Extracorporeal Shockwave Lithotripsy for Upper Ureteric Stones
...Show More Authors

Background: Extracorporeal Shock wave lithotripsy (ESWL) is widely used in treating patients with ureteralstones because it is effective, safe, and noninvasive. Based on factors such as size and the location of stones,there is a significant variation in the overall stone-free rate (SFR).Aim of the study: To evaluate the effect of ureteral wall thickness (UWT), stone attenuation, the time fromfirst attack of pain till first session of ESWL and stone/ rib density on the outcome of SWL in the treatmentof upper ureteral stones (UUS).Patient and methods: A prospective study when 127 patients with radio-opaque UUS ranging from 7 to 20mm and treated by ESWL were included in this study. The effect of (stone/ 12th rib) density by KUB, ureter

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Sun Feb 01 2026
Journal Name
Journal Of Baghdad College Of Dentistry
An evaluation of an Iraqi phosphate-bonded investment and a commercial type on the marginal fit of ceramometalcopings using three different investing and burnout techniques
...Show More Authors

Background: The accuracy of fitness of any dental casting is imperative for the success of any prosthodontic treatment. From the time that dental casting was first introduced, efforts have been made to produce more accurate and better fitted castings with minimal marginal discrepancy. The aim of this in vitro study was to evaluate the effects of three different investing and burnout techniques on the vertical marginal discrepancies ofceramometalcopings invested with two types of phosphate- bonded investments. Materials and methods: Sixty wax patterns were fabricated on a standardized prepared brass die representing an upper central incisor by the aid of a custom-made split mold. Three different investing and burnout techniques were applied

... Show More
View Publication Preview PDF