This paper details the process of designing, analysing, manufacturing, and testing an integrated solid-state hydrogen storage system. Analysis is performed to optimise flow distribution and pressure drop through the channels, and experimental investigations compare the effects of profile shape on the overall power output from the fuel cell. The storing of hydrogen is given much attention in the selection of a storage medium, and the effect of a cooling system to reduce the recharging time of the hydrogen storage vessel. The PTFE seal performed excellently, holding pressure over 60 bar, despite requiring changing each time the cell is opened. The assembly of the vessel was simple and straightforward, and there was no indication of pressure damage owing to the FEA analysis that was performed. The cooling chamber, although producing minor leaks due to design oversight, increased performance dramatically, showing a reduction in internal powder temperature from 130°C, down to 25°C during the absorption process, as well as reducing the absorption time down from 30 minutes to just over 5 minutes. The novel idea of implanting a sheathed thermocouple into the centre of the hydride powder proved to be highly valuable asset and provided important information, especially during desorption where the outside container could be heating up, while the inner powder is still cooling down, data that have not been seen before.
This paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show More
Detection of virulence gene agglutinin-like sequence (ALS) 1 by using molecular technology from clinical samples (
The study aimed to establish the association of miR-153-3p expression with treatment response to IM in CML patients. Sixty CML patients were included and divided into two groups consistent with their response to treatment whether sensitive or resistant to IM. Ten healthy normal participants were enrolled as control group. RNA was extracted from serum to work out miR-153-3p expression utilizing real-time quantitative reverse transcription polymerase chain reaction. The primers were supplied by Macrogen Inc. Twenty seven patients were sensitive to imatinib and 33 were resistant to imatinib. The ratio of male to female was 1.14:1. The bulk (58%) of patients were within the age range of 41-60 years. Weight and gender did not significantly diffe
... Show MoreABSTRACT Background: work-related musculoskeletal disorders represent an important occupational health issues among dentists especially neck and low back complaints. Biomarkers of tissue damage as results of occupational physical demands could be used for detection of work related musculoskeletal disorders. Aim: The aim of this study was to assess work- related musculoskeletal disorders, physical work load index, selected salivary biomarkers (Creatine kinase and C - reactive protein) and to find the relation among them. Subjects and Methods: Study participants are consisted of 112 dentists. They were selected from college of dentistry /Baghdad University, health care center in Bagdad city. They were of both gender and aged between 40-45 yea
... Show MoreHR Al-Hamamy, KE Sharquie, AA Noaimi, WN Hussein, Our Dermatology Online, 2014 - Cited by 6
In this study the Entrance Surface Dose (ESD) received by pediatrics patients undergoing chest, abdomen and skull X-ray examinations was estimated. The study was conducted in two hospitals in Najaf city where three radiographic systems were considered. The study participants were classified into four age groups 0-1 , 1-5 , 5-10 and 10-15 years. Calculations were performed using exposure factors, kVp, mAs and focal-skin distance, together with patient data age. The ESD was calculated for the involved patients who underwent an Antero-posterior (AP) chest, abdomen and skull X-ray examination. The resulted data were analyzed and compared with international dose references. For all studied radiographic examinations and all X-ray mac
... Show MoreObjective: The study aimed to identify the adolescents' family meal eating patterns, and find out the relationship between adolescents' family meal eating patterns and their weight control behaviors. Methodology: A descriptive study was conducted on impact of adolescents' family meal eating patterns upon their weight control behaviors in secondary schools at Baghdad city, starting from 20th of April 2013 to the end of October 2014. Non- probability (purposive) sample of 1254 adolescents were chosen from secondary schools of both sides of Al-Karkh and Al-Russafa sectors. Data was collected through a specially
Abstract: Aluminum alloys grade 6061-T6 are characterized by their excellent properties and processing characteristics which make them ideal for varieties of industrial applications under cyclic loading, aluminum alloys show less fatigue life than steel alloys of similar strength. In the current study, a nanosecond fiber laser of maximum pulse energy up to 9.9 mJ was used to apply laser shock peening process (LSP) on aluminum thin sheets to introduce residual stresses in order to enhance fatigue life under cyclic loading Box-Behnken design (BBD) based on the design of experiments (DOE) was employed in this study for experimental design data analysis, model building and optimization The effect of working parameters spot size (ω), scannin
... Show More