Preferred Language
Articles
/
12HBTZkBdMdGkNqj2SU8
CROSS-SECTIONAL REGRESSION WITH PROXIES: A SEMI-PARAMETRIC METHOD
...Show More Authors

This study investigates asset returns within the Iraq Stock Exchange by employing both the Fama-MacBeth regression model and the Fama-French three-factor model. The research involves the estimation of cross-sectional regressions wherein model parameters are subject to temporal variation, and the independent variables function as proxies. The dataset comprises information from the first quarter of 2010 to the first quarter of 2024, encompassing 22 publicly listed companies across six industrial sectors. The study explores methodological advancements through the application of the Single Index Model (SIM) and Kernel Weighted Regression (KWR) in both time series and cross-sectional analyses. The SIM outperformed the KWR approach in estimating time-varying beta coefficients, yielding a mean Root Mean Squared Error (RMSE) of 0.14316. Furthermore, the integrated KWR-SIM methodology achieved the lowest Adjusted Root Mean Squared Error (ARMSE) value of 0.08152 when modelling the association between risk factors and asset returns within the cross-sectional analytical framework. Statistical tests for significance produced heterogeneous responses of the returns on assets in the Iraqi financial market to the Fama-French posited economic variables. The estimated coefficients for the betas showed significant oscillations for all assets, confirming changes in economic conditions. The results add to our knowledge of the risk-reward relationship in the context of emerging markets and provide methodological insights into financial asset pricing. The evidence indicates that the KWR-SIM method has better capabilities for model fitting

Scopus
View Publication
Publication Date
Wed Feb 01 2023
Journal Name
International Journal Of Advanced And Applied Sciences
Application of the updated DeLone and McLean IS success method to investigate e-CRM effectiveness
...Show More Authors

Information and communication technology has a significant influence on employee procedures. Businesses are investing in e-CRM technologies, yet it is difficult to assess the performance of their e-CRM platforms. The DeLone and McLean Information Systems Success framework can be modified to the current e-CRM assessment difficulties. The new framework's different aspects provide a concise framework for organizing the e-CRM key metrics identified in this study. The purpose of this study is to apply and verify that the Updated DeLone and McLean IS Model can be employed to explain e-CRM adoption among employees, along with the extended Updated DeLone and McLean Model with its five output factors, namely system quality, service quality,

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Mar 30 2021
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Removal of Vanadium and Nickel Ions from Iraqi Atmospheric Residue by Using Solvent Extraction Method
...Show More Authors

Iraqi crude Atmospheric residual fraction supplied from al-Dura refinery was treated to remove metals contaminants by solvent extraction method, with various hydrocarbon solvents and concentrations. The extraction method using three different type solvent (n-hexane, n-heptane, and light naphtha) were found to be effective for removal of oil-soluble metals from heavy atmospheric residual fraction. Different solvents with using three different hydrocarbon solvents (n-hexane, n-heptane, and light naphtha) .different variables were studied solvent/oil ratios (4/1, 8/1, 10/1, 12/1, and 15/1), different intervals of perceptual (15, 30-60, 90 and 120 min) and different temperature (30, 45, 60 and 90 °C) were used. The metals removal perce

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Oct 01 2015
Journal Name
International Journal Of Current Engineering And Technology
Synthesis of Gold Nanoparticle in the form of Paper Willow by Hot Chemical Reduction Method
...Show More Authors

Abstract: Colloidal gold nanoparticles (ringworm Palm or in the form of paper willow) have been prepared from HAuCl4 containing aqueous solution by hot chemical reduction method. The colloidal gold nanoparticles were characterized by SEM, EDX, and UV-VIS absorption spectroscopy. It was found that the variation of reduction time from boiling point affects the size of the nanoparticles and also in chemical reduction approach the size of nanoparticles can be controlled by varying the amount of variation the volume of reductant material with respect to the volume of HAuCL4.

Preview PDF
Publication Date
Mon Jul 01 2019
Journal Name
Iop Conference Series: Materials Science And Engineering
Influence of water in size of Synthesized Carbon Black Nanoparticles from Kerosene by Flame Method
...Show More Authors

View Publication
Scopus (4)
Scopus Crossref
Publication Date
Thu Dec 03 2015
Journal Name
Iraqi Journal Of Science
New multispectral images classification method based on MSR and Skewness implementing on various sensor scenes
...Show More Authors

Publication Date
Fri Mar 01 2024
Journal Name
Water, Air, & Soil Pollution
Decontamination of Cobalt-Polluted Soils Using an Enhanced Electro-kinetic Method, Employing Eco-friendly Conditions
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Mon Dec 03 2012
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
The Effect of Window Size Changing on Satellite Image Segmentation Using 2D Fast Otsu Method
...Show More Authors

Publication Date
Wed Aug 01 2018
Journal Name
International Journal Of Novel Research In Electrical And Mechanical Engineering
Use of Panel Method in High Subsonic and Transonic Aerodynamic Analysis of Complex Aircraft Configuration
...Show More Authors

The application of low order panel method with the Dirichlet boundary condition on complex aircraft configuration have been studied in high subsonic and transonic speeds. Low order panel method has been used to solve the case of the steady, inviscid and compressible flow on a forward swept wing – canard configuration with cylindrical fuselage and a vertical stabilizer with symmetrical cross section. The aerodynamic coefficients for the forward swept wing aircraft were calculated using measured wake shape from an experimental work on same model configuration. The study showed that the application of low order panel method can be used with acceptable results

View Publication
Publication Date
Thu Oct 09 2025
Journal Name
Chemical And Process Engineering Research
Spectrophotometric Determination of Sulfanilamide in Pure and in Synthetic Sample based on Condensation Reaction Method
...Show More Authors

A new, Simple, sensitive and accurate spectrophotometric methods have been developed for the determination of sulfanilamide (SNA) drug in pure and in synthetic sample. This method based on the reaction of sulfanilamide (SNA) with 1,2-napthoquinone-4-sulphonic acid (NQS) to form N-alkylamono naphthoquinone by replacement of the sulphonate  group of the naphthoquinone sulphonic acid by an amino group. The colored chromogen shows absorption maximum at 455 nm. The optimum conditions of condensation reaction forms were investigated by: (1) univariable method, by optimizing the effect of experimental variables; (different bases, reagent concentration, borax concentration and reaction time),     (2) central  composite design (CCD) including

... Show More
View Publication Preview PDF
Publication Date
Thu Feb 29 2024
Journal Name
Sabrao Journal Of Breeding And Genetics
LOW-‎COST SOIL ‎MOISTURE SENSORS’ ASSESSMENT FOR THEIR ACCURACY AFTER CALIBRATION THROUGH THE ‎GRAVIMETRIC METHOD
...Show More Authors

The existing study aimed to assess four soil moisture sensors’ capacitive (WH51 and SKU: S EN0193) and resistive (Yl69 and IC Station) abilities, which are affordable and medium-priced for their accuracy in six common soil types in the central region of Iraq. The readings’ calibration for the soil moisture sensor devices continued through two gravimetric methods. The first depended on the protocols’ database, while the second was the traditional calibration method. The second method recorded the lowest analysis error compared with the first. The moderate-cost sensor WH51 showed the lowest standard error (SE), MAD , and RMSE and the highest R² in both methods. The performance accuracy of WH51 was close to readings shown by the manufac

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref