Preferred Language
Articles
/
0xeBeI0BVTCNdQwCLBQG
Solid Phase Extraction of Theophylline in Aqueous Solutions by Modified Magnetic Iron Oxide Nanoparticles as an Extractor Material and Spectrophotometry Technique for the Determination
...Show More Authors

new, simple and fast solid-phase extraction method for separation and preconcentration of trace theophylline in aqueous solutions was developed using magnetite nanoparticles (MIONPs) coated with aluminium oxide (AMIONPs) and modified with palmitate (P) as an extractor (P@AMIONPs). It has shown that the developed method has a fast absorbent rate of the theophylline at room temperature. The parameters that affect the absorbent of theophylline in the aqueous solutions have been investigated such as the amount of magnetite nanoparticle, pH, standing time and the volume, concentration of desorption solution. The linear range, limit of quantification (LOQ) and limit of detection (LOD) for the determination of theophylline were 0.05-2.450 μg mL- 1, 0.05 μg. mL-1 and 0.032 (n=10) respectively. The PF (Preconcentration factor) obtained for the proposed method in 98% is 75. The intra-day and interday precisions were 2.1% and 3.6% (for 1.0 μg mL-1, n=10). The relative standard deviation R.S.D for 1.0 μg mL-1 is 1.26 (n=10). The proposed method has been successfully applied for the determination of theophylline in the pharmaceutical preparations.

View Publication
Publication Date
Thu Jan 06 2022
Journal Name
Chemical Papers
A solvent collection technique using dispersive liquid–liquid microextraction coupled with spectrophotometry for the trace determination of folic acid in pure, dosage forms and flaxseed
...Show More Authors

A simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl

... Show More
View Publication
Scopus (5)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Sep 01 2020
Journal Name
Iraqi Journal Of Physics
The magnetic switch manufacturing by using ferrofluid and ferrofluid doped copper nanoparticles
...Show More Authors

In this work, a magnetic switch was prepared using two typesof ferrofluid materials, the pure ferrofluid and ferrofluid doped with copper nanoparticles (10 nm). The critical magnetic field (Hc) and the state of magnetic saturation (Hs) were studied using three types of laser sources. The main parameters of the magnetic switch measured using pure ferrofluid and He-Ne Laser source were Hc(0.5 mv, 0.4 G), Hs (8.5 mv, 3 G). For the ferrofluid doped with copper nanoparticles were Hc (1 mv, 4 G), Hs (15 mv, 9.6 G), Using green semiconductor laser for the Pure ferrofluid were Hc (0.5 mv, 0.3 G) Hs (15 mv, 2.9 G). While the ferrofluid doped with copper nanoparticles were Hc (0.5 mv, 1 G), Hs (12 mv, 2.8 G) and by using the violet semiconductor l

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 02 2008
Journal Name
Baghdad Science Journal
The Spectroscopic Behaviour of Rhodamine 6G in Liquid and Solid Solutions
...Show More Authors

Absorption, fluorescence, quantum yield and lifetime of rhodamine 6G in chloroform, methanol and dimethyl sulfoxide were measured. From a comparison of these quantities, with those for solid solutions (solid solutions are obtained by mixing constant volume proportions of dye at a concentration of 1*10-4M/l with different volume proportions from the concentrated solution of polymer in chloroform and dimethyl sulfoxide). The results showed that the addition of polymer to liquid concentrated solutions (1*10-4M/l )of rhodamine 6G dye from expecting [which leading to development active medium for laser dye at high concentration] increase the spectra shift toward high energies, and the luminescence quantum yield but decreasing radiative lifetim

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Tue Dec 31 2024
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Extraction and preconcentration of many metals ions by using CPE technique
...Show More Authors

Cloud point extraction is a simple, safe, and environmentally friendly technique for preparing many different kinds of samples. In this review, we discussed the CPE method and how to apply it to our environmental sample data. We also spoke about the benefits, problems, and likely developments in CPE. This process received a great deal of attention during preconcentration and extraction. It was used as a disconnection and follow-up improvement system before the natural mixtures (nutrients, polybrominated biphenyl ethers, pesticides, polycyclic sweet-smelling hydrocarbons, polychlorinated compounds, and fragrant amines) and inorganic mixtures were examined and many metals like (silver, lead, cadmium, mercury, and so on). We also find

... Show More
View Publication
Scopus (5)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Mar 30 2024
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Caffeine Extraction from Spent Coffee Grounds by Solid-liquid and Ultrasound-assisted Extraction: Kinetic and Thermodynamic Study
...Show More Authors

Coffee is the most essential drink today, aside from water, the high consumption of coffee and the byproducts of its soluble industries such as spent coffee grounds can have a negative effect on the environment as a source of toxic organic compounds. Therefore, caffeine removal from the spent coffee ground can be applied as a method to limit the effect of its production on the environment. The aim of this study is to determine the kinetics and thermodynamics parameters and develop models for both processes based on the process parameters by using traditional solid-liquid extraction and Ultrasound-assisted extraction methods. The processes were performed at a temperature range of 25 to 55 °C for traditional and ultrasound baths, and

... Show More
View Publication
Crossref (3)
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Journal Of Al-nahrain University
DETERMINATION OF SERUM TRACE ELEMENTSMAGNESIUM, COPPER, ZINC, AND SELENIUM IN ASTHMATIC PATIENTS BY ATOMIC ABSORPTION SPECTROPHOTOMETRY
...Show More Authors

The aim of this study is to evaluate the levels of trace elements Magnesium (Mg), Zinc (Zn), Copper (Cu), and Selenium (Se) in blood sera of asthmatic patients by Atomic Absorption Spectrophotometry (AAS). The concentrations of Mg, Cu, and Zn have been determined by Flame Atomic Absorption spectrophotometry (FAAS), and Se with flameless Graphite Furnace Atomic Absorption Spectrophotometry (GFAAS). The study involves (55) asthmatic patients as study group and (28) subjects as control from both genders. Serum levels of Mg, Cu, and Se were significantly higher (p<0.001 for all) in patients when compared with healthy subjects, while Zn level was relatively significant (p<0.05). Our observations confirm the efficacy and applicability of (AAS) in

... Show More
Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of Global Pharma Technology
Using tobacco leaves as adsorbent for the orange-g dye removal from its aqueous solutions
...Show More Authors

The removal of commercial orange G dye from its aqueous solution by adsorption on tobacco leaves (TL) was studied in respect to different factor that affected the adsorption process. These factors including the tobacco leaves does, period of orange G adsorption, pH, and initial orange G dye concentration .Different types of isotherm models were used to describe the orange G dye adsorption onto the tobacco leaves. The experimental results were compared using Langmuir, and frundlich adsorption isotherm, the constants for these two isotherm models was determined. The results fitted frundlich model with value of correlation coefficient equal to (0.981). The capacity of adsorption for the orange G dye was carried out using various kinetic models

... Show More
Scopus (7)
Scopus
Publication Date
Thu Mar 09 2017
Journal Name
University Of Baghdad
Synthesis of modified Graphene Oxide and its application as Electrochemical Sensor
...Show More Authors

This study involved preparation of Graphene oxide (GO) and reduced graphene oxide (RGO) using Hummer method and chemical method respectively. These carbon nanomaterials were used as starting material to make novel functionalize with thiocarbohydrazide (TCH) which was prepared by reacting CS2 with hydrazine to form GO or RGO- 4-amino,5-substituted 1H,1,2,4 Triazole 5(4H) thion (ASTT) ,(GOT) and( RGOT) respectively via cyclocondensation reaction. Also MnO2 nanorod was prepared to form hybridized with GOT and RGOT. A commercial multiwall carbon nanotube (MWCNT) and functionalization with carboxylic groups' (f-MWCNT) and its nanocomposite with GOT were also prepared. All carbon nanomaterials were characterized with different techniques such as

... Show More
Preview PDF
Publication Date
Wed Mar 01 2023
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations
...Show More Authors

The present study describes employing zero-, 1st - and 2nd -order derivative spectrophotometric methods have been developed for determination of lorazepam (LORA) and clonazepam (CLON) in commercially available tablets. LORA was determined by means of 1st (D1), 2nd (D2) derivative spectrophotometric techniques using zero cross, peak height, and Peak area. D1 used for the determination of CLON by using zero cross and peak height while D2 (zero cross) was used for the determination of CLON. The method was established to be linear in concentration containing different ratios of LORA and CLON range of (20-200 mg/L) and (5-35 mg/L) at wavelength range (250 -370 nm), (210-370nm) respectively. The proposed techniques are highly sensitive, precise a

... Show More
Preview PDF
Publication Date
Wed Jun 29 2022
Journal Name
Egyptian Journal Of Chemistry
First- and Second-Derivative Spectrophotometry for Simultaneous Determination of lorazepam and clonazepam in pharmaceutical formulations.
...Show More Authors

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref