The primary goal of in-situ load testing is to evaluate the safety and performance of a structural system under particular loading conditions. Advancements in building techniques, analytical tools, and monitoring instruments are prompting the evaluation of the appropriate loading value, loading process, and examination criteria. The procedure for testing reinforced concrete (RC) structures on-site, as outlined in the ACI Building Code, involves conducting a 24-h load test and applying specific evaluation criteria. This article detailed a retrofitting project for an RC slab-beams system by utilizing carbon fiber-reinforced polymer (CFRP) sheets to strengthen the structure following a fire incident. The RC structure showed indicators of deterioration, including deflections, concrete cracking, and concrete spalling in some zones. Whereas, a detailed presentation of the strengthening procedure as well as its evaluation, rationale for the loading procedure, instrumentation needs, assessment criteria, and outcomes of the field testing. The study concentrated on assessing the structure of the RC slab-beam system with widespread cracking in both the positive and negative moment areas. The finite element model was created and examined to help with the load test design, and it confirmed the field findings considerably. The proposed finite element (FE) model demonstrated a reduced estimation of net deflection value in comparison to the corresponding actual values. It maintained a highly acceptable mean value of 0.843 and a small deviation limit of 6.8%.
Our country faced lots of crises specially Wars and still living under the traumatic events. This would result in psychological disorder specially the Acute Stress Disorder (ASD). That’s if not treated, it will turn to be over Post Traumatic Stress Disorder(PTSD). Also not mentioning the shortage of recourses speaks about war and crises. That treat with its inflections psychologically and sociologically theses cases if happened.
The importance of this study arise through it is objective to introduce a program for EMDR which give benefit for treat in health, social, educational institutes.
Aims:
The objective of this Study is the identification of a Test the effectiveness of Eye Movement Desensi
... Show MoreA New developed technique to estimate the necessary six elastic constants of homogeneous laminate of special orthotropic properties are presented in this paper for the first time. The new approach utilizes the elasto-static deflection behavior of composite cantilever beam employing the famous theory of Timoshenko. Three extracted strips of the composite plate are tested for measuring the bending deflection at two locations. Each strip is associated to a preferred principal axis and the deflection is measured in two orthogonal planes of the beam domain. A total of five trails of testing is accomplished and the numerical results of the stiffness coefficients are evaluated correctly under the contribution of the macromechanic
... Show MoreSovereign wealth funds have attracted the attention of the governments of the oil and non-oil countries alike, with a variation of the size of those funds to those states, based on the size of the financial surpluses resulting from Alriadat oil or foreign reserves, or state revenues for other sovereign assets. Raj use these funds remarkably during the financial crises the world has seen, including the crisis of 2008-2007., And Iraq is a oil-producing countries, which has the third largest reserves of crude oil (Crude Oil) at the level of the Arab world and of 140 300)) million barrels after Saudi Saudi Arabia and the Islamic Republic of Iran, and the fourth reserves of crude oil in the world after issued Venezuela to the reserve
... Show MoreIn a hybrid cooling solar thermal systems , a solar collector is used to convert solar energy into heat energy in order to super heat the refrigerant leaving the compressor, and this process helps in the transformation of refrigerant state from gaseous state to the liquid state in upper two-thirds of the condenser instead of the lower two-thirds such as in the traditional air-conditioning systems and this will reduce the energy needed to run the process of cooling .In this research two systems with a capacity of 2 tons each were used, a hybrid air-conditioning system with an evacuated tubes solar collector and a traditional air-conditioning system . The refrigerant of each type was R22.The comparison was in the amou
... Show MoreBackground:This is a prospective study of three children presented to us in the Orbital clinic in AL ShahidGazi Al Hariri Hospital with painless proptosiswith suspension of Hydatid disease.Objectives: : Orbital hydatid disease is a rare lesion accounting for less than 1% of the total lesions of the body (1, 2). Orbital cysts presented as a primary lesion in our study which is rare to have such lesion without involvement of other organs (3). Humans represent the intermediate host where the commonly affected organ are liver and the lung (10-15%) (4). Methods:This is a prospective study of three Children presented to us in the Orbital clinic in Al Shahid Ghazi Alhariri Hospital with painless proptosis with suspension of Hydatid disease, dep
... Show MorePermeability is one of the essential petrophysical properties of rocks, reflecting the rock's ability to pass fluids. It is considered the basis for building any model to predict well deliverability. Yamama formation carbonate rocks are distinguished by sedimentary cycles that separate formation into reservoir units and insulating layers, a very complex porous system caused by secondary porosity due to substitute and dissolution processes. Those factors create permeability variables and vary significantly. Three ways used for permeability calculation, the firstly was the classical method, which only related the permeability to the porosity, resulting in a weak relationship. Secondly, the flow zone indicator (FZI) was divided reservoir into
... Show More