Preferred Language
Articles
/
0Bc1L48BVTCNdQwCCV3D
Non-thermal pasteurization of milk by elongated electrode moderate electrical field: Chemical and sensory analysis during cold storage and shelf-life determination
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Fri Apr 30 2021
Journal Name
Egyptian Journal Of Chemistry
Indirect Spectrophotometric Determination of Mebendazole Using NBromosuccinimide as An Oxidant and Tartarazine Dye as Analytical Reagent
...Show More Authors

A simple indirect spectrophotometric method for determination of mebendazol in pure and pharmaceutical formulation was presented in this study. UV-Visible spectrophotometry using the optimal conditions was developed for determination of mebendazole in pure drug and different preparation samples. The method is based on the oxidation of drug by nbromosuccinimide with hydrochloric acid and the left amount of oxidizing agent was determined by the reaction with tartarazine and the absorbance was measured at 428 nm. Calibration curves were linear in the range of 5 to 30 µg.mL-1 with molar absorptivity 8437.2 L.mol-1 .cm-1 . The limits of detection and quantification were determined and found to be 0.7770 µg.mL-1 and 2.3400 µg.mL-1 respec

... Show More
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
High performance liquid chromatographic method for the determination of guaifenesin in pharmaceutical syrups and in environmental samples
...Show More Authors

A simple, precise, rapid, and accurate reversed – phase high performance liquid chromatographic method has been developed for the determination of guaifenesin in pure from pharmaceutical formulations.andindustrial effluent. Chromatography was carried out on supelco L7 reversed- phase column (25cm × 4.6mm), 5 microns, using a mixture of methanol –acetonitrile-water: (80: 10 :10 v/v/v) as a mobile phase at a flow rate of 1.0 ml.min-1. Detection was performed at 254nm at ambient temperature. The retention time for guaifenesin was found 2.4 minutes. The calibration curve was linear (r= 0.9998) over a concentration range from 0.08 to 0.8mg/ml. Limit of detection (LOD) and limit of quantification ( LOQ) were found 6µg/ml and 18µg/ml res

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 01 2023
Journal Name
Baghdad Science Journal
Simultaneous Determination of Piroxicam and Codeine Phosphate Hemihydrate in a Pharmaceutical Dosage Form Using Validated HPLC Method
...Show More Authors

An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jul 01 2012
Journal Name
Food Chemistry
High performance liquid chromatographic determination of aflatoxins in chilli, peanut and rice using silica based monolithic column
...Show More Authors

A simple and rapid high performance liquid chromatographic with fluorescence detection method for the determination of the aflatoxin B1, B2, G1 and G2 in peanuts, rice and chilli was developed. The sample was extracted using acetonitrile:water (90:10, v/v%) and then purified by using ISOLUTE multimode solid phase extraction. After the pre-column derivatisation, the analytes were separated within 3.7 min using Chromolith performance RP-18e (100–4.6 mm) monolithic column. To assess the possible effects of endogenous components in the food items, matrix-matched calibration was used for the quantification and validation. The recoveries of aflatoxins that were spiked into food samples were 86.38–104.5% and RSDs were <4.4%. The method was

... Show More
View Publication
Scopus (90)
Crossref (81)
Scopus Clarivate Crossref
Publication Date
Sun Apr 25 2021
Journal Name
Egyptian Journal Of Chemistry
Indirect spectrophotometric determination of Mebendazole using n-bromosuccinimide as an oxidant and tartarazine dye as analytical reagent
...Show More Authors

View Publication Preview PDF
Scopus (13)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Surface Hardness Measurement of Stone and Improved Die Stone After the Addition of a Mixture of Chemical Additives with Different Proportion
...Show More Authors

Background: Incorporation of chemical additives has long been a technique used to improve properties of the gypsum products. The purpose of this work was to study the effects of adding a combination of gum Arabic and calcium hydroxide to a type III dental stone and type IV improved die stone with different proportion. The effect on water/powder ratio, and surface hardness was determined. Material and method: Both material stone and die stone were blended with two proportion of additives so that each material was mixed twice but with different proportion of gum Arabic (0.1% and 0.2%) and calcium hydroxide (0.5 % and 0.3%). Data for hardness were subjected to two-way analysis of variance. Results: The results revealed that the chemical additi

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Sat Jun 15 2024
Journal Name
Obstetrics & Gynaecology Forum
THE ROLE OF FUNGAL INFECTIONS IN THE PATHOGENESIS OF DIALYSIS-DEPENDENT AND NON-DIALYSIS-DEPENDENT PATIENTS WITH KIDNEY DISEASE
...Show More Authors

Abstract The results of isolation, morphological and microscopic diagnosis, Chromic Agar, Vitik technology and Bact Alert showed that the diagnosis of fungi isolated from blood samples of end-stage renal patients who did not undergo dialysis and those who underwent dialysis was 60 samples for each type. The total number of fungal isolates isolated from people who did not undergo dialysis was 26 pathogenic fungal isolates, with a percentage frequency of 43.33%. In this study, 4 genera of pathogenic fungi were identified: Candida spp, Rhodotorula spp, Cryptococcus spp. and Aspergillus spp. The number of Candida isolates reached 13 isolates, with a frequency of 50%. The results also showed that the diagnosed species from the genus Rhodotorula

... Show More
Publication Date
Fri Mar 28 2008
Journal Name
Ama, Agricultural Mechanization In Asia, Africa & Latin America
The Effect of Two Type of Plows With Four Speeds on the Field Capacity and Bulk Density
...Show More Authors

Publication Date
Sun Jun 30 2019
Journal Name
Journal Of The College Of Education For Women
Ready-made clothes for students of the University of Baghdad between reality and ambition ( A field study )
...Show More Authors

     تعد الملابس وسيلة هامة لكل مايقوم به الانسان في حياته العامة ، فهي الانطباع والكلمة الخارجية عن ذاته الداخلية فهي تعكس فكرة الفرد عن ذاته وعن شخصيته , كما تعد وسيلة تعبير جمالية وفنية , فهي تساعد على اخفاء عيوب الجسد وابراز محاسنه . ويتوقف اختيار الفرد لملابسه على مجموعة  عوامل منها احتياجه , قدراته المالية , سنه , مركزه الاجتماعي , طبيعة عمله ,الظروف الجوية التي يعيش فيها وعلى مايُؤمن به من قيم و

... Show More
View Publication
Publication Date
Fri Jul 19 2024
Journal Name
Baghdad Science Journal
Synthesis, Characterization, and Thermal Studying of VO(II), Cu(II), Zn (II), Cd(II), and Au (III) Complexes with Azo Dye and Evaluation as Antioxidants
...Show More Authors

حضرت معقدات كل من الفنادايل, الخارصين, النحاس والكادميوم بتكافؤهم الثنائي والذهب بتكافؤه الثلاثي بأستخدام صبغة ازوجديدة (6،4،2-ثلاثي هيدروكسي-3-((3-هيدروكسي فنيل) ثنائي زينيل ) فنيل ) ايثان-1-اون المحضرة من ملح الديازونيوم مع ٦,٤,٢- ثلاثي هيدروكسي اسيتوفينون بعد عزل (E)-1-(2,4,6-trihydroxy-3-((3-hydroxyphenyl)diazenyl)phenyl)ethan-1-one تم تشخيصها بواسطة الطرق الطيفية المتاحة  والتقنيات التشخيصية لكل من التحليل الدقيق للعناصرواطياف كل من ال

... Show More
View Publication
Scopus Clarivate Crossref